journal article·2022-03-14Open access

Thermally Controllable Decolorization of Reusable Radiochromic Complex of Polyvinyl Alcohol, Iodine and Silica Nanoparticles (PAISiN) Irradiated with γ-rays

Hiroshi Yasuda, Hirokazu Miyoshi

Applied Sciences· Volume 12· Issue 6

Abstract

Some medical and industry workers using ionizing radiation sources have potential risks of accidental high-dose exposure of their extremities, particularly their hands. While practical dosimeters suitable for on-site real-time monitoring of hand exposure are not yet available, they are desirable to be developed. Thus, the authors focused on the application of a reusable radiochromic complex composed of polyvinyl alcohol, iodide and silica nanoparticles, named “PAISiN”, and examined their dose responses and thermal stabilities of radiochromic reactions. Three PAISiN samples each were irradiated with 5, 10 and 20 Gy of 137Cs γ-rays, and time changes of the radiation-induced colors were observed at different temperatures: 20 °C (in a laboratory), 40 °C (in an oven) and 5.5 °C (in a refrigerator). It was confirmed that the PAISiN samples presented a red color that was easily detectable by the naked eyesight immediately after irradiation. The coloration was cleared within 24 h for 5 Gy irradiation at room temperature. The decolorization process was remarkably accelerated at 40 °C; it was erased in just 2 h. In contrast, storing in the refrigerator (5.5 °C) kept the color persistently for at least 4 days. These findings indicate that we could flexibly control the decolorization process of PAISiN in accordance with the objective of radiation monitoring.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Radiotherapy Techniques · Radiation Dose and Imaging · Radiation Effects and Dosimetry

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Radiation Biophysics, Research Institute for Radiation Biology and Medicine, Hiroshima University, Hiroshima 734-8553, Japan

Advance Radiation Research, Education, and Management Center, Tokushima University, Tokushima 770-8501, Japan

Funding

Japan Society for the Promotion of Science

References (44)

Show source-provided references
1. Evaluation of radiation exposure to staff and environment dose from [18F]-FDG in PET/CT and cyclotron center using thermoluminescent dosimetry
2. An overview on extremity dosimetry in medical applications10.1093/rpd/ncn149 ↗
3. Potential Radiation-Related Effects on Radiologists10.2214/AJR.16.17212 ↗
4. Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) (2022, February 09). Report to Parliament—Radiation Exposure of a Worker at ANSTO Health, Lucas Heights on 22 August 2017, Available online: https://www.arpansa.gov.au/about-us/corporate-publications/reports-parliament/report-parliament-radiation-exposure-worker-ansto.
5. Occupational radiation exposure of health professionals and cancer risk assessment for Lithuanian nuclear medicine workers10.1016/j.envres.2020.109144 ↗
6. International Commission on Radiological Protection (ICRP) (2007). 2007 Recommendations of the International Commission on Radiological Protection, ICRP. Publication 103, Ann. ICRP 37(2–4).
7. Imaging of radiation dose by visible color development in ferrous agarose xylenol orange gels10.1118/1.596676 ↗
8. Optical CT reconstruction of 3D dose distributions using the ferrous benzo-ic-xylenol (FBX) gel dosimeter10.1118/1.598356 ↗
9. Tissue-equivalent gel for noninvasive spatial radiation dose measurements10.1016/S0168-583X(99)00873-3 ↗
10. Sensitivity and stability of the Fricke–gelatin–xylenol orange gel dosimeter10.1016/j.radphyschem.2008.01.007 ↗
11. Polymer gel dosimetry10.1088/0031-9155/55/5/R01 ↗
12. Radio-physical properties of micelle leucodye 3D integrating gel dosimeters10.1088/0031-9155/56/3/007 ↗
13. Optimization of the sensitivity and stability of the PRESAGE™ dosimeter using trihalomethane radical initiators10.1016/j.radphyschem.2012.03.022 ↗
14. Leuco-crystal-violet micelle gel dosimeters: II. Recipe optimization and testing10.1088/0031-9155/60/12/4685 ↗
15. True 3D chemical dosimetry (gels, plastics): Development and clinical role10.1088/1742-6596/573/1/012003 ↗
16. Characterization of a reusable PRESAGE® 3D dosimeter10.1088/1742-6596/573/1/012039 ↗
17. Reversible radiochromic plate based on polyvinyl alcohol-iodide complex containing silica nanoparticles10.1007/s10967-015-4465-y ↗
18. Mijnheer, B. (2017). Radiochromic 3D Detectors. Clinical 3D Dosimetry in Modern Radiation Therapy, CRC Press. [1st ed.].10.1201/9781315118826-1 ↗
19. PRESAGE® as a solid 3D dosimeter: A review article10.1016/j.radphyschem.2017.06.002 ↗
20. Development of the gel indicator using PVA and KI
21. Novel GTA-PVA Fricke gels for three-dimensional dose mapping in radiotherapy10.1016/j.radmeas.2017.07.003 ↗
22. Fricke gel dosimeters with low-diffusion and high-sensitivity based on a chemically cross-linked PVA matrix10.1016/j.radmeas.2017.02.012 ↗
23. Fricke-gel dosimeter: Overview of Xylenol Orange chemical behavior10.1016/j.radphyschem.2017.01.012 ↗
24. Characterisation of two new radiochromic gel dosimeters TruViewTM and ClearViewTM in combination with the vistaTM optical CT scanner: A feasibility study10.1016/j.ejmp.2018.07.002 ↗
25. Leuco crystal violet-Pluronic F-127 3D radiochromic gel dosimeter10.1088/1361-6560/ab2f5d ↗
26. Novel radiochromic gel dosimeter based on a polyvinyl alcohol—Iodide complex10.1016/j.radmeas.2019.106226 ↗
27. Influence of the components of a radiochromic PVA-Iodide gel dosimeter on the thermal and spatial stability10.1016/j.radmeas.2020.106338 ↗
28. Dhakal, R., Yosofvand, M., and Moussa, H. (2021). Development and application of MAGIC-f gel in cancer research and medical imaging. Appl. Sci., 11.10.3390/app11177783 ↗
29. Annealing properties of the PVA-GTA-I gel dosimeter10.1016/j.radmeas.2021.106674 ↗
30. Newton, J.R., Recht, M., Hauger, J.A., Segarra, G., Inglett, C., Romo, P.A., and Adamovics, J. (2021). Feasibility of a reusable radiochromic dosimeter. Appl. Sci., 11.10.3390/app11219906 ↗
31. Capture of charge carriers at the silica nanoparticle-water interface10.1021/jp992269e ↗
32. Particle dispersion in silica-poly(vinyl alcohol) coatings: Role of particle-polymer interaction10.15376/biores.13.2.3195-3207 ↗
33. Rasband, W.S. (2022, February 09). ImageJ, Available online: https://imagej.nih.gov/ij/.
34. Review of Fricke gel dosimeters10.1088/1742-6596/3/1/003 ↗
35. Polyvinyl alcohol as a useful Iindicator on iodometry: Volumetric and spectrophotometric studies on iodine-PVA and iodine-starch complexes10.2116/analsci.17.333 ↗
36. Effects of PVA-GTA-I radiochromic gel dosimeter components on optical dose-response10.1088/1742-6596/2167/1/012014 ↗
37. Iodine-poly(vinyl alcohol) interactions, 5. Releasing mechanism of I− and I2 in the decomposition process of the blue complex10.1002/macp.1993.021940126 ↗
38. Radical Scavenging in the sonolysis of aqueous Solutions of I−, Br−, and N3−10.1021/j100168a061 ↗
39. Charge carrier transfer across the silica nanoparticle/water interface10.1021/jp982129p ↗
40. Molecular iodine/polymer complexes10.1515/polyeng-2012-0122 ↗
41. Critical review of rate constants for reactions of hydrated electrons, hydrogen atoms and hydroxyl radicals (•OH/•O∑) in aqueous solution10.1063/1.555805 ↗
42. Papirer, E. (2000). Adsorption on Silica Surfaces, Marcel Dekker Inc.10.1201/9781482269703 ↗
43. Path to achieving molecular dispersion in a dense reactive mixture10.1002/polb.23789 ↗
44. Characterization of the crosslinking reaction in high performance adhesives10.1016/j.ijadhadh.2017.08.006 ↗