Preprocessing for Lessening the Influence of Eye Artifacts in EEG Analysis
Source abstract
Abstract
We dealt with the problem of artifacts in EEG signals in relation to the usage of lengthy trials. Specifically, we considered eye artifacts found in EEG signals, their influence in the analysis of the data and alternatives to diminish their impact on later studies of brain activity on lengthy tasks. We proposed a scheme of partial rejection of independent signal components, provided a method to extract EEG signal components with diminished influence of eye artifacts, and assess the importance of using artifact free signal excerpts to extract signal components in order to analyze brain activity in a musical context.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: EEG and Brain-Computer Interfaces · Neural dynamics and brain function · Blind Source Separation Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
ATIC Research Group, E.T.S.I. Telecomunicación, Universidad de Málaga, Andalucía Tech, Campus Universitario de Teatinos s/n, 29071 Málaga, Spain
Funding
Ministerio de Economía, Industria y Competitividad, Gobierno de España · Danish National Research Foundation
References (25)
Show source-provided references
1. Luck, S.J. (2014). An Introduction to the Event-Related Potential Technique, MIT Press.
2. A study of evoked potentials from ear-EEG10.1109/TBME.2013.2264956 ↗
3. Removal of ocular artifact from the EEG: A review10.1016/S0987-7053(00)00055-1 ↗
4. Analysis of blink rate patterns in normal subjects10.1002/mds.870120629 ↗
5. Correction of EOG Artifacts in Event-Related Potentials of the EEG: Aspects of Reliability and Validity10.1111/j.1469-8986.1982.tb02509.x ↗
6. The removal of the eye-movement artifact from the EEG by regression analysis in the frequency domain10.1016/0301-0511(83)90059-5 ↗
7. Adaptive AR modeling of nonstationary time series by means of Kalman filtering10.1109/10.668741 ↗
8. SVD based technique for noise reduction in electroencephalographic signals10.1016/S0165-1684(96)00129-6 ↗
9. Removing electroencephalographic artifacts by blind source separation10.1111/1469-8986.3720163 ↗
10. Dipole modelling of eye activity and its application to the removal of eye artefacts from the EEG and MEG10.1088/0143-0815/12/A/010 ↗
11. Blind noise reduction for multisensory signals using ICA and subspace filtering, with application to EEG analysis10.1007/s00422-001-0298-6 ↗
12. Zhou, W. (2002, January 23–26). Removal of ECG artifacts from EEG using ICA. Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society, Houston, TX, USA.
13. Automatic removal of the eye blink artifact from EEG using an ICA-based template matching approach10.1088/0967-3334/27/4/008 ↗
14. Automatic removal of eye movement and blink artifacts from EEG data using blind component separation10.1111/j.1469-8986.2003.00141.x ↗
15. Automated EEG artifact elimination by applying machine learning algorithms to ICA-based features10.1088/1741-2552/aa69d1 ↗
16. Croce, P., Zappasodi, F., Marzetti, L., Merla, A., Pizzella, V., and Chiarelli, A.M. (2018). Deep Convolutional Neural Networks for feature-less automatic classification of Independent Components in multi-channel electrophysiological brain recordings. IEEE Trans. Biomed. Eng.10.1109/TBME.2018.2889512 ↗
17. Event-related brain responses while listening to entire pieces of music10.1016/j.neuroscience.2015.10.061 ↗
18. The ten-twenty electrode system of the International Federation
19. (2018). MATLAB, The MathWorks Inc.. Version: 9.5.0.1033004 Update 2.
20. FieldTrip: open source software for advanced analysis of MEG, EEG, and invasive electrophysiological data10.1155/2011/156869 ↗
21. An algorithm separating saccadic from nonsaccadic eye movements automatically by use of the acceleration signal10.1016/0042-6989(92)90031-D ↗
22. Artifacts removing from EEG signals by ICA algorithms10.9790/1676-0241116 ↗
23. Functionally independent components of the late positive event-related potential during visual spatial attention10.1523/JNEUROSCI.19-07-02665.1999 ↗
24. An improved P300-based brain-computer interface10.1109/TNSRE.2004.841878 ↗
25. Signal-to-noise ratio of the MEG signal after preprocessing10.1016/j.jneumeth.2013.10.019 ↗