journal article·2019-12

Recent Tomographic Imaging Developments at the PSICHE Beamline

A. King, N. Guignot, J.-P. Deslandes, M. Pelerin, I. Joosten, D. De Looff, J. Li, L. Bertrand, E. Rosenberg, A. Dewaele, E. Boulard, Y. Le Godec, J.-P. Perrillat, E. Giovenco, G. Morard, T. Weitkamp, M. Scheel, J. Perrin, H. Chevreau, J.-P. Itié

Publisher page

Abstract

PSICHE is a high-energy, multi-technique beamline at the SOLEIL synchrotron facility. It performs X-ray tomography for materials science and other applications and X-ray diffraction for samples at extreme conditions. The beamline has been in service for user experiments since 2013, but is in continual development to add new capabilities. In this article, we present a series of new developments which combine diffraction and tomography and which are of relevance to the study of materials and manufacturing. By combining these techniques, we can add quantitative structural information from diffraction to morphological information obtained by tomography. Recent developments in very fast tomography allow dynamic processes to be studied in situ and in 3D with a time (frequency) resolution of 2 Hz. We have developed in situ sample environments to enable fast tomography measurements at high temperature and pressure, which will allow future studies of industrial processes such as hot isostatic pressing (HIP).
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced X-ray Imaging Techniques · Nuclear Physics and Applications · X-ray Spectroscopy and Fluorescence Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. King A, Guignot N, Zerbino P, Boulard E, Desjardins K et al (2016) Tomography and imaging at the PSICHE beamline of the SOLEIL synchrotron. Rev Sci Instrum 87:093704. https://doi.org/10.1063/1.496136510.1063/1.4961365 ↗
2. Wang Y, Uchida T, Von Dreele R, Rivers ML, Nishiyama N, Funakoshi K, Nozawa A, Keneko H (2004) A new technique for angle-dispersive powder diffraction using an energy-dispersive setup and synchrotron radiation. J Appl Crystallogr 37:947–95610.1107/S0021889804022502 ↗
3. Li J, Guériau P, Bellato M, King A, Robbiola L, Thoury M, Baillon M, Fossé C, Cohen SX, Moulhérat C, Thomas A, Galtier P, Bertrand L (2019) Synchrotron-based phase mapping in corroded metals: insights from early copper-base artifacts. Anal Chem 91(3):1815–1825. https://doi.org/10.1021/acs.analchem.8b0274410.1021/acs.analchem.8b02744 ↗
4. Rivers M (2017) High-speed tomography using pink beam at GeoSoilEnviroCARS. In: Conference: SPIE optical engineering + applications, United States. https://doi.org/10.1117/12.223824010.1117/12.2238240 ↗
5. Nielsen SF, Wolf A, Poulsen HF, Ohler M, Lienert U, Owen RA (2000) A conical slit for three-dimensional XRD mapping. J Synchrotron Radiat 7:103–109. https://doi.org/10.1107/S090904950000062510.1107/S0909049500000625 ↗
6. Martins RV, Honkimäki V (2003) Depth resolved strain and phase mapping of dissimilar friction stir welds using high energy synchrotron radiation. Texture Microstruct 35:145–152. https://doi.org/10.1080/0730330031000162862510.1080/07303300310001628625 ↗
7. Bleuet P, Welcomme E, Dooryhée E, Susini J et al (2008) Probing the structure of heterogeneous diluted materials by diffraction tomography. Nat Mater 7:468–472. https://doi.org/10.1038/nmat216810.1038/nmat2168 ↗
8. Goldstein JI, Newbury DE, Michael JR, Ritchie NWM, Scott JHJ, Joy DC (2018) Scanning electron microscopy and X-ray microanalysis. Springer, New York. https://doi.org/10.1007/978-1-4939-6676-910.1007/978-1-4939-6676-9 ↗
9. Maire E, Withers PJ (2014) Quantitative X-ray tomography. Int Mater Rev 59(1):1–4310.1179/1743280413Y.0000000023 ↗
10. Rack A, Scheel M, Hardy L, Curfs C, Bonnin A, Reichart H (2014) Exploiting coherence for real-time studies by single bunch imaging. J Synchrotron Radiat 21:815–818. https://doi.org/10.1107/S160057751400585210.1107/S1600577514005852 ↗
11. pco.dimax HS4. PCO AG, Germany. https://www.pco.de/highspeed-cameras/pcodimax-hs4/ . Accessed 29 April 2019
12. Weitkamp T, Scheel M, Giorgetta JL, Joyet V, Le Roux V, Cauchon G, Moreno T, Polack F, Samama JP (2017) The tomography beamline ANATOMIX at Synchrotron SOLEIL. In: IOP conference series: journal of physics conference series, vol 849, p 012037. https://doi.org/10.1088/1742-6596/849/1/01203710.1088/1742-6596/849/1/012037 ↗
13. Cnudde V, Boone MN (2013) High-resolution X-ray computed tomography in geosciences: a review of the current technology and applications. Eath Sci Rev 123:1–17. https://doi.org/10.1016/j.earscirev.2013.04.00310.1016/j.earscirev.2013.04.003 ↗
14. Fusseis F, Xiao X, Schrank C, De Carlo F (2014) A brief guide to synchrotron radiation-based microtomography in (structural) geology and rock mechanics. J Struct Geol 65:1–16. https://doi.org/10.1016/j.jsg.2014.02.00510.1016/j.jsg.2014.02.005 ↗
15. Mao WL, Lin Y, Liu Y, Liu J (2019) Applications for nanoscale imaging at high pressure. Engineering. https://doi.org/10.1016/j.eng.2019.01.00610.1016/j.eng.2019.01.006 ↗
16. Lin Y, Zeng Q, Yang W, Mao WL (2013) Pressure-induced densification in GeO2 glass: a transmission x-ray microscopy study. Appl Phys Lett 103:261909. https://doi.org/10.1063/1.486099310.1063/1.4860993 ↗
17. Philippe J, Le Godec Y, Mezouar M, Berg M et al (2016) Rotating tomography Paris–Edinburgh cell: a novel portable press for micro-tomographic 4-D imaging at extreme pressure/temperature/stress conditions. High Press Res. https://doi.org/10.1080/08957959.2016.122195110.1080/08957959.2016.1221951 ↗
18. Wang Y, Uchida T, Westferro F, Rivers ML et al (2005) High-pressure X-ray tomography microscope: synchrotron computed microtomography at high pressure and temperature. Rev Sci Instrum 76:073709–1–073709–6. https://doi.org/10.1063/1.197947710.1063/1.1979477 ↗
19. Boulard E, King A, Guignot N, Deslandes J-P et al (2018) High-speed tomography under extreme conditions at the PSICHE beamline of the SOLEIL Synchrotron. J Synchrotron Radiat 25:818–825. https://doi.org/10.1107/S160057751800486110.1107/S1600577518004861 ↗
20. Urakawa S, Terasaki HP, Funakoshi K, Uesugi K, Yamamoto S (2010) Development of high pressure apparatus for X-ray microtomography at SPring-8. J Phys Conf Ser 215:012026. https://doi.org/10.1088/1742-6596/215/1/01202610.1088/1742-6596/215/1/012026 ↗
21. Kak AC, Slaney M (1988) Principles of computerized tomographic imaging. IEEE Press
22. Weitkamp T, Haas D, Wegrzynek D, Rack A (2011) ANKAphase: software for single-distance phase retrieval from inline X-ray phase-contrast radiographs. J Synchrotron Radiat 18:617–629. https://doi.org/10.1107/S090904951100289510.1107/S0909049511002895 ↗