Accuracy of Different Systems of Guided Implant Surgery and Methods for Quantification: A Systematic Review
Source abstract
Abstract
The aim of this systematic review was to assess the scientific literature on the accuracy of guided implant surgery and the methods used for its quantification. Two reviewers searched PubMed and the Cochrane Library to identify relevant articles published before 2023. Two methodological quality-assessment tools were used to assess the quality of the studies included. Inter-investigator reliability was verified using kappa statistics. Twenty-three clinical studies out of the 3299 articles initially identified met the inclusion criteria. The “radiographic matching method” and “digital registration method” were used to assess accuracy in guided surgery. The mean angular, coronal, and apical deviations of mucosa-supported guides ranged from 2.7° to 5.14°, 0.87 mm to 2.05 mm, and 1.08 mm to 2.28 mm, respectively. With bone-supported guides, these ranged from 2.49° to 5.08°, 0.71 mm to 1.60, and 0.77 mm to 1.65 mm, respectively. In tooth-supported guides, deviations were from 2.5° to 5.62°, 0.39 mm to 1.63 mm and 0.28 mm, and 1.84 mm, respectively. Regardless of the evaluation method, all systems exhibit some error. The minimum and maximum deviation ranges found between the planned and placed implants show that, although deviations occur, guided surgery is not far from accurate.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Dental Radiography and Imaging · Orthodontics and Dentofacial Orthopedics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Dental Clinical Specialties, School of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain
Surgical and Implant Therapies in the Oral Cavity Research Group, Complutense University of Madrid, 28040 Madrid, Spain
References (65)
Show source-provided references
1. The Impact of the Fabrication Method on the Three-Dimensional Accuracy of an Implant Surgery Template10.1016/j.jcms.2017.02.015 ↗
2. Digital Workflow for Computer-Guided Implant Surgery in Edentulous Patients: A Case Report10.1016/j.joms.2017.08.008 ↗
3. Accuracy of Computer-Guided Surgery for Dental Implant Placement in Fully Edentulous Patients: A Systematic Review10.4103/ejd.ejd_249_17 ↗
4. A Systematic Review on the Accuracy and the Clinical Outcome of Computer-Guided Template-Based Implant Dentistry10.1111/j.1600-0501.2009.01788.x ↗
5. In Vivo Tooth-Supported Implant Surgical Guides Fabricated With Desktop Stereolithographic Printers: Fully Guided Surgery Is More Accurate Than Partially Guided Surgery10.1016/j.joms.2018.02.010 ↗
6. Consensus Statements and Recommended Clinical Procedures Regarding Computer-Assisted Implant Dentistry
7. Healing of Peri-Implant Tissues after Flapless and Flapped Implant Installation: Healing of Peri-Implant Tissues after Implant Installation10.1111/j.1600-051X.2011.01735.x ↗
8. Accuracy of Guided Surgery via Stereolithographic Mucosa-Supported Surgical Guide in Implant Surgery for Edentulous Patient: A Systematic Review10.5037/jomr.2018.9101 ↗
9. Influence of Surgeon Experience on the Accuracy of Implant Placement via a Partially Computer-Guided Surgical Protocol10.11607/jomi.7480 ↗
10. Accuracy of a Guided Implant System with Milled Surgical Templates10.2334/josnusd.21-0361 ↗
11. How Does an Error in Positioning the Template Affect the Accuracy of Implants Inserted Using a Single Fixed Mucosa-Supported Stereolithographic Surgical Guide?10.1016/j.ijom.2013.06.012 ↗
12. The Influence of Guided Sleeve Height, Drilling Distance, and Drilling Key Length on the Accuracy of Static Computer-Assisted Implant Surgery10.1111/cid.12705 ↗
13. Accuracy of Dynamic Navigation for Dental Implant Placement-Model-Based Evaluation10.1563/aaid-joi-D-16-00025 ↗
14. Accuracy of Virtually Planned and Conventionally Placed Implants in Edentulous Cadaver Maxillae and Mandibles: A Preliminary Report10.1016/j.prosdent.2014.05.008 ↗
15. Accuracy of a Newly Developed Cone-Beam Computerized Tomography-Aided Surgical Guidance System for Dental Implant Placement: An Ex Vivo Study10.1563/AAID-JOI-D-11-00062 ↗
16. Accuracy of CAD/CAM-Guided Surgical Template Implant Surgery on Human Cadavers: Part I10.1016/S0022-3913(10)60072-8 ↗
17. Virtual Variation Simulation of CAD/CAM Template-Guided Surgeries Performed on Human Cadavers: Part II10.1016/S0022-3913(10)60089-3 ↗
18. Accuracy Assessment of Computer-Assisted Flapless Implant Placement in Partial Edentulism10.1111/j.1600-051X.2010.01535.x ↗
19. The Cochrane Collaboration’s Tool for Assessing Risk of Bias in Randomised Trials10.1136/bmj.d5928 ↗
20. Efficacy of Standard (SLA) and Modified Sandblasted and Acid-etched (SLA Ctive) Dental Implants in Promoting Immediate and/or Early Occlusal Loading Protocols: A Systematic Review of Prospective Studies10.1111/clr.12347 ↗
21. Accuracy Comparison of Guided Surgery for Dental Implants According to the Tissue of Support: A Systematic Review and Meta-Analysis10.1111/clr.12841 ↗
22. Clinical Factors Affecting the Accuracy of Guided Implant Surgery—A Systematic Review and Meta-Analysis10.1016/j.jebdp.2017.07.007 ↗
23. A Randomized Clinical Trial Comparing Guided Implant Surgery (Bone- or Mucosa-supported) with Mental Navigation or the Use of a Pilot-drill Template10.1111/jcpe.12231 ↗
24. Accuracy and Patient-Centered Outcome Variables in Guided Implant Surgery: A RCT Comparing Immediate with Delayed Loading10.1111/clr.12583 ↗
25. The Accuracy of Single-tooth Implants Placed Using Fully Digital-guided Surgery and Freehand Implant Surgery10.1111/jcpe.13160 ↗
26. A Randomized Controlled Study on the Accuracy of Free-handed, Pilot-drill Guided and Fully Guided Implant Surgery in Partially Edentulous Patients10.1111/jcpe.12897 ↗
27. Accuracy Evaluation of Partially Guided and Fully Guided Templates Applied to Implant Surgery of Anterior Teeth: A Randomized Controlled Trial10.1111/cid.12980 ↗
28. Deviations between Placed and Planned Implant Positions: An Accuracy Pilot Study of Skeletally Supported Stereolithographic Surgical Templates: Accuracy of Placed and Planned Implant Positions10.1111/cid.12019 ↗
29. Factors Affecting Accuracy of Implant Placement with Mucosa-Supported Stereolithographic Surgical Guides in Edentulous Mandibles10.1016/j.compbiomed.2013.07.029 ↗
30. Accuracy of Dental Implant Placement Using CBCT-Derived Mucosa-Supported Stereolithographic Template10.1111/cid.12189 ↗
31. A Clinically Relevant Accuracy Study of Computer-Planned Implant Placement in the Edentulous Maxilla Using Mucosa-Supported Surgical Templates10.1111/cid.12112 ↗
32. An Accuracy Study of Computer-Planned Implant Placement in the Augmented Maxilla Using Mucosa-Supported Surgical Templates10.1111/cid.12230 ↗
33. Accuracy of Computer-Guided Implant Surgery by a CAD/CAM and Laser Scanning Technique
34. Evaluation of Accuracy and Precision of a New Guided Surgery System: A Multicenter Clinical Study
35. Accuracy Evaluation of Computer-Designed Surgical Guide Template in Oral Implantology10.1016/j.jcms.2015.10.022 ↗
36. The Accuracy of Guided Surgery via Mucosa-Supported Stereolithographic Surgical Templates in the Hands of Surgeons with Little Experience10.1111/clr.12494 ↗
37. An Accuracy Study of Computer-Planned Implant Placement in the Augmented Maxilla Using Osteosynthesis Screws10.1016/j.ijom.2016.10.013 ↗
38. The Accuracy of Computer-guided Implant Surgery with Tooth-supported, Digitally Designed Drill Guides Based on CBCT and Intraoral Scanning. A Prospective Cohort Study10.1111/clr.13514 ↗
39. Accuracy of Static Fully Guided Implant Placement in the Posterior Area of Partially Edentulous Jaws: A Cohort Prospective Study10.1007/s00784-021-04254-3 ↗
40. Accuracy Evaluation of the Computer-Designed Selective Laser Sintering Surgical Guide for Flapless Immediate Loading Dental Implants Surgery in Edentulous Jaws10.1563/aaid-joi-D-20-00071 ↗
41. Accuracy of a Computer-Aided Implant Surgical Technique10.11607/prd.1019 ↗
42. Accuracy of Positioning of Implants Inserted Using a Mucosa-Supported Stereolithographic Surgical Guide in the Edentulous Maxilla and Mandible10.11607/jomi.3329 ↗
43. Accuracy of Computer-Guided Flapless Implant Surgery in Fully Edentulous Arches and in Edentulous Arches With Fresh Extraction Sockets10.1097/ID.0000000000000878 ↗
44. 3D Accuracy of Implant Positions in Template-Guided Implant Placement as a Function of the Remaining Teeth and the Surgical Procedure: A Retrospective Study10.1007/s00784-018-2339-8 ↗
45. Flapless Implant Surgery in the Edentulous Jaw Based on Three Fixed Intraoral Reference Points and Image-Guided Surgical Templates: Accuracy in Human Cadavers10.1111/j.1600-0501.2009.01884.x ↗
46. Computer Technology Applications in Surgical Implant Dentistry: A Systematic Review
47. Accuracy of Computer-aided Implant Placement10.1111/j.1600-0501.2012.02552.x ↗
48. Comparison of the Tensile Modulus of Three 3D-Printable Materials Used in Dentistry10.17219/dmp/166070 ↗
49. Jacobs, R., Salmon, B., Codari, M., Hassan, B., and Bornstein, M.M. (2018). Cone Beam Computed Tomography in Implant Dentistry: Recommendations for Clinical Use. BMC Oral Health, 18.10.1186/s12903-018-0523-5 ↗
50. Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol10.1155/2017/4292081 ↗
51. Yi, C., Li, S., Wen, A., Wang, Y., Zhao, Y., and Zhang, Y. (2022). Digital versus Radiographic Accuracy Evaluation of Guided Implant Surgery: An in Vitro Study. BMC Oral Health, 22.10.1186/s12903-022-02585-5 ↗
52. Comparative Study of the Accuracy of CBCT Implant Site Measurements Using Different Software Programs10.1016/j.sdentj.2020.07.003 ↗
53. Is It Possible to Improve the Accuracy of Implants Inserted with a Stereolithographic Surgical Guide by Reducing the Tolerance between Mechanical Components?10.1016/j.ijom.2013.01.011 ↗
54. The Influence of the Tolerance between Mechanical Components on the Accuracy of Implants Inserted with a Stereolithographic Surgical Guide: A Retrospective Clinical Study10.1111/cid.12120 ↗
55. The Intrinsic Error of a Stereolithographic Surgical Template in Implant Guided Surgery10.1016/j.ijom.2012.06.010 ↗
56. Clinical Accuracy of Flapless Computer-Guided Surgery for Implant Placement in Edentulous Arches10.11607/jomi.3156 ↗
57. Depth and Lateral Deviations in Guided Implant Surgery: An RCT Comparing Guided Surgery with Mental Navigation or the Use of a Pilot-Drill Template10.1111/clr.12460 ↗
58. Accuracy of a Dedicated Bone-Supported Surgical Template for Dental Implant Placement with Direct Visual Control10.1260/2040-2295.6.4.779 ↗
59. How Much Does Experience in Guided Implant Surgery Play a Role in Accuracy? A Randomized Controlled Pilot Study10.1016/j.ijom.2017.03.010 ↗
60. A Randomized Controlled Clinical Trial Comparing Conventional and Computer-Assisted Implant Planning and Placement in Partially Edentulous Patients. Part 4: Accuracy of Implant Placement10.11607/prd.4147 ↗
61. Analysis of Linear and Angular Deviations of Implants Installed With a Tomographic-Guided Surgery Technique: A Prospective Cohort Study10.1563/aaid-joi-D-18-00265 ↗
62. Vinci, R., Manacorda, M., Abundo, R., Lucchina, A.G., Scarano, A., Crocetta, C., Lo Muzio, L., Gherlone, E.F., and Mastrangelo, F. (2020). Accuracy of Edentulous Computer-Aided Implant Surgery as Compared to Virtual Planning: A Retrospective Multicenter Study. JCM., 9.10.3390/jcm9030774 ↗
63. Accuracy of Half-Way Mucosa-Supported Implant Guides for Edentulous Jaws: A Retrospective Study with a Median Follow-up of 2 Years10.1177/0300060521999739 ↗
64. Accuracy Evaluation of Computer-Guided Implant Surgery Associated with Prototyped Surgical Guides10.1016/j.prosdent.2019.07.010 ↗
65. Accuracy of Digital Surgical Guides for Dental Implants10.1186/s40902-022-00364-4 ↗