Since the setting characterization of a root canal sealer has an impact on its biological behavior of final obturation, this study evaluated the setting characterization of mineral trioxide aggregate MTA-Fillapex versus MTA-Bioseal compared with epoxy resin (Adseal) root canal sealers. Freshly mixed sealer was inserted into the mold (n = 10). The initial and final setting times were evaluated using a Vicat needle and were then statistically analyzed by one-way ANOVA at p < 0.05. The raw pastes and the stages of the setting reaction were analyzed using Fourier Transform Infrared (FTIR) Spectroscopy. The phase compositions were evaluated using X-ray diffraction (XRD). A significant and fast setting time was recorded by Adseal (4.7 ± 0.46 h) followed by MTA-Bioseal (11.4 ± 1.34 h) at p < 0.001. The MTA-Fillapex did not set completely in three months. The FTIR and XRD of both MTA-Bioseal and Adseal detected bands of the polymerized phases, while those of MTA-Fillapex detected partial polymerization with a low percentage of polymerized silica. MTA-Bioseal and Adseal met the ISO standards for setting times. However, MTA-Fillapex did not fulfill the ideal requirement for the sealer. Although the raw pastes of both MTA-sealers had nearly similar compositions, they behaved differently during the hydration reaction. MTA-Bioseal set completely, while MTA-Fillapex was not completely set.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Endodontics and Root Canal Treatments · Dental materials and restorations · Dental Radiography and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Endodontic Department, Faculty of Dentistry, King Abdulaziz University, Jeddah 21589, Saudi Arabia

Endodontic Department, Faculty of Dentistry, Cairo University, Giza 12613, Egypt

References (54)

Show source-provided references
1. Materials used for root canal obturation: Technical, biological and clinical testing10.1111/j.1601-1546.2005.00197.x ↗
2. Grossman, L.I. (1988). Endodontic Practice, Lea & Febiger. [11th ed.].
3. Physical and chemical properties of a new root-end filling material10.1016/S0099-2399(06)80967-2 ↗
4. “MTA”—An hydraulic silicate cement: Review update and setting reaction10.1016/j.dental.2011.02.001 ↗
5. Mineral trioxide aggregate: A comprehensive literature review-part I: Chemical, physical, and antibacterial properties10.1016/j.joen.2009.09.006 ↗
6. The setting characteristics of MTA Plus in different environmental conditions10.1111/iej.12068 ↗
7. Factors affecting the periapical healing process of endodonti-cally treated teeth10.1590/1678-7757-2016-0464 ↗
8. In vitro cytotoxicity of a new epoxy resin root canal sealer10.1097/00004770-200008000-00008 ↗
9. Physical properties of root canal cements10.1016/S0099-2399(76)80059-3 ↗
10. Angulus Science and Technology (2021, August 22). MTA-Fillapex Endodontic Sealer, Scientific Profile. Available online: http://www.angelusdental.com/img/arquivos/mta_fillapex_technical_profile_download.pdf.
11. Benezra, M.K., Wismayer, P.S., and Camilleri, J. (2017). Influence of environment on testing of hydraulic sealers. Sci. Rep., 7.10.1038/s41598-017-17280-7 ↗
12. Setting properties and cytotoxicity evaluation of a premixed bioceramic root canal sealer10.1016/j.joen.2011.01.003 ↗
13. Lee, J.K., Kwak, S.W., Ha, J.-H., Lee, W., and Kim, H.-C. (2017). Physicochemical properties of epoxy resin-based and bioceramic-based root canal sealers. Bioinorg. Chem. Appl., 2017.10.1155/2017/2582849 ↗
14. ITENA Clinical Product (2021, August 20). MTA-Bioseal, White Paper—Dental Sky. Available online: https://www.dentalsky.com.
15. Physical properties of 5 root canal sealers10.1016/j.joen.2013.06.012 ↗
16. International Organization for Standardization (2001). ISO 6876: Dental Root Canal Sealing Materials, International Organization for Standardization.
17. American National Standards/American Dental Association (2000). ANSI/ADA Specification No. 57: Endodontic Sealing Material, American National Standards/American Dental Association.
18. Ahmadi, S.M., Behnamghader, A., Sharifipoor, S., and Farsadzadeh, B. (2012, January 12–14). Effect of nano flourhydroxyapatite (nFHA) addition on the acellular bioactivity of MTA cement: An invitro assessment. Proceedings of the 4th International Conference on Nanostructures (ICNS4), Kish Island, Iran.
19. Micro-FTIR study of the blend of humates with calcium hydroxide used to prepare smokeless fuel briquettes10.1016/S0924-2031(03)00089-4 ↗
20. Apatite-forming ability (bioactivity) of ProRoot MTA10.1111/j.1365-2591.2010.01768.x ↗
21. Okamura, T., Chen, L., Tsumano, N., Ikeda, C., Komasa, S., Tominaga, K., and Hashimoto, Y. (2020). Biocompatibility of a High-Plasticity, Calcium Silicate-Based, Ready-to-Use Material. Materials, 13.10.3390/ma13214770 ↗
22. Early hydration and setting of Portland cement monitored by IR, SEM and Vicat techniques10.1016/j.cemconres.2009.01.017 ↗
23. FT-IR imaging of native and tissue-engineered bone and cartilage10.1016/j.biomaterials.2006.11.043 ↗
24. Delgado, A.H., and Young, A.M. (2021). Modelling ATR-FTIR Spectra of Dental Bonding Systems to Investigate Composition and Polymerisation Kinetics. Materials, 14.10.3390/ma14040760 ↗
25. Enhancing mechanical properties of epoxy resin using waste lignin and salicylate alumoxane nanoparticles10.1007/s11814-017-0301-0 ↗
26. Hydration study of ordinary portland cement in the presence of zinc ions10.1590/S1516-14392007000400002 ↗
27. Hybrid composites of conductive polyaniline and nanocrystalline titanium oxide prepared via self-assembling and graft polymerization10.1016/j.polymer.2006.08.059 ↗
28. Morphological and chemical analysis of different precipitates on mineral trioxide aggregate immersed in different fluids10.4012/dmj.2009-133 ↗
29. Self setting bone cement formulations based on egg shell derived tetracalcium phosphate bioceramics
30. Modena, E. (2012). Spectroscopic Study of Bioceramics for Endodontics and Orthopaedics. [Ph.D Thesis, Alma Mater Studiorum—Università di Bologna].
31. Baseline studies of the clay minerals society source clays: Infrared methods10.1346/CCMN.2001.0490508 ↗
32. Vibrational investigation of calcium-silicate cements for endodontics in simulated body fluids10.1016/j.molstruc.2010.12.058 ↗
33. In-vitro bioactivity evaluation and physical properties of an epoxy-based dental sealer reinforced with synthesized fluorine-substituted hydroxyapatite, hydroxyapatite and bioactive glass nanofillers
34. FTIR and SEM analysis of polyester-and epoxy-based composites manufactured by VARTM process10.1002/app.27857 ↗
35. Study of the curing process of an epoxy resin by FTIR spectroscopy10.1081/PPT-100101414 ↗
36. Applications of FTIR on epoxy resins-identification, monitoring the curing process, phase separation and water uptake
37. FTIR study of bonding between a thermoplastic healing agent and a mendable epoxy resin10.1016/j.vibspec.2009.09.005 ↗
38. Influence of modification of SiO2 on the formation of calcium silicate hydrate
39. Curing FTIR study and mechanical characterization of glass bead filled trifunctional epoxy composites10.1016/j.compscitech.2006.10.006 ↗
40. Effect of selected accelerants on setting time and biocompatibility of mineral trioxide aggregate (MTA)10.1016/j.tripleo.2010.07.013 ↗
41. Properties of BioRoot RCS, a tricalcium silicate endodontic sealer modified with povidone and polycarboxylate10.1111/iej.12856 ↗
42. Physicochemical and mechanical properties of zirconium oxide and niobium oxide modified Portland cement-based experimental endodontic sealers10.1111/iej.12167 ↗
43. Physical properties of MTA Fillapex sealer10.1016/j.joen.2013.04.015 ↗
44. Physical properties and interfacial adaptation of three epoxy resin-based sealers10.1016/j.joen.2011.06.023 ↗
45. Setting time and expansion in different soaking media of experimental accelerated calcium-silicate cements and ProRoot MTA10.1016/j.tripleo.2009.07.039 ↗
46. In situ assessment of the setting of tricalcium silicate–based sealers using a dentin pressure model10.1016/j.joen.2014.09.015 ↗
47. Synthesis and characterization of a glycerol salicylate resin for bioactive root canal sealers10.1111/iej.12149 ↗
48. Physico-chemical investigation of endodontic sealers exposed to simulated intracanal heat application: Epoxy resins and zinc oxide–eugenols10.1111/iej.13267 ↗
49. Vibrational spectroscopy of selective dental restorative materials10.1080/05704928.2016.1244069 ↗
50. Microscopic analysis of the quality of obturation and physical properties of MTA F illapex10.1002/jemt.22432 ↗
51. Carbonation behavior of hydraulic and non-hydraulic calcium silicates: Potential of utilizing low-lime calcium silicates in cement-based materials10.1007/s10853-016-9909-4 ↗
52. Physicochemical analysis of MTA Angelus® and Biodentine® conducted with X ray difraction, dispersive energy spectrometry, X ray fluorescence, scanning electron microscope and infra red spectroscopy10.1016/j.rodmex.2016.02.023 ↗
53. Abu Zeid, S., Edrees, H.Y., Mokeem Saleh, A.A., and Alothmani, O.S. (2021). Physicochemical properties of two generations of MTA-based root canal sealers. Materials, 14.10.3390/ma14205911 ↗
54. DSC and FTIR analysis of the curing behaviors of epoxy/DICY/solvent open systems10.1016/S0040-6031(98)00356-6 ↗