journal article·2023-01-10Open access

Concurrent Validity of the Inertial Measurement Unit Vmaxpro in Vertical Jump Estimation

Jose M. Jimenez-Olmedo, Basilio Pueo, Jose M. Mossi, Lamberto Villalon-Gasch

Applied Sciences· Volume 13· Issue 2

Abstract

The aim of this study was to evaluate if the inertial measurement unit (IMU) Vmaxpro is a valid device to estimate vertical jump height (VJH) when compared to a motion capture system (MoCAP). Thirteen highly trained female volleyball players participated in this study which consisted of three sessions. After a familiarization session, two sessions comprised a warm-up followed by ten countermovement jumps, resting two min between each attempt. Jump height was measured simultaneously by Vmaxpro using take-off velocity and MoCAP using center-of-mass vertical excursion. Results show significant differences in jump height between devices (10.52 cm; p < 0.001; ES = 0.9), a very strong Spearman’s correlation (rs = 0.84: p < 0.001), and a weak concordance correlation coefficient (CCC = 0.22; ρ = 0.861; Cb = 0.26). Regression analysis reveals very high correlations, high systematic error (8.46 cm), and a nonproportional random error (SEE = 1.67 cm). Bland–Altman plots show systematic error (10.6 cm) with 97.3 % of the data being within the LoA. In conclusion, Vmaxpro can be considered a valid device for the estimation of VJH, being a cheaper, portable, and manageable alternative to MoCAP. However, the magnitude of systematic error discourages its use where indistinguishable data from Vmaxpro and MoCAP are used unless the corresponding specific fitting equation is applied.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Sports Performance and Training · Sports injuries and prevention · Lower Extremity Biomechanics and Pathologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Research Group in Health, Physical Activity and Sports Technology (Health-Tech), Physical Education and Sport, University of Alicante, 03690 San Vicente del Raspeig, Spain

ITeam, Institute of Telecommunications and Multimedia Applications, Universitat Politècnica de València, 46022 Valencia, Spain

Funding

Generalitat Valenciana

References (62)

Show source-provided references
1. Current Methodologies and Implications of Phase Identification of the Vertical Jump: A Systematic Review and Meta-Analysis10.1007/s40279-015-0350-7 ↗
2. Accuracy of Jump-Mat Systems for Measuring Jump Height10.1123/ijspp.2016-0511 ↗
3. Soler-López, A., García-de-Alcaraz, A., Moreno-Villanueva, A., and Pino-Ortega, J. (2022). Concurrent Validity and Reliability of Devices to Measure Jump Height in Men’s Handball Players. Sensors, 22.10.3390/s22239070 ↗
4. Condello, G., Khemtong, C., Lee, Y.-H., Chen, C.-H., Mandorino, M., Santoro, E., Liu, C., and Tessitore, A. (2020). Validity and Reliability of a Photoelectric Cells System for the Evaluation of Change of Direction and Lateral Jumping Abilities in Collegiate Basketball Athletes. J. Funct. Morphol. Kinesiol., 5.10.3390/jfmk5030055 ↗
5. Maximum Velocity during Loaded Countermovement Jumps Obtained with an Accelerometer, Linear Encoder and Force Platform: A Comparison of Technologies10.1016/j.jbiomech.2019.07.025 ↗
6. The Validity and Reliability of an IPhone App for Measuring Vertical Jump Performance10.1080/02640414.2014.996184 ↗
7. Common Vertical Jump and Reactive Strength Index Measuring Devices: A Validity and Reliability Analysis10.1519/JSC.0000000000003988 ↗
8. Validity and Test-Retest Reliability of the Jumpo App for Jump Performance Measurement
9. Watkins, C.M., Maunder, E., Tillaar, R.V.D., and Oranchuk, D.J. (2020). Concurrent Validity and Reliability of Three Ultra-Portable Vertical Jump Assessment Technologies. Sensors, 20.10.3390/s20247240 ↗
10. Comparison of Two Methods in the Estimation of Vertical Jump Height10.14198/jhse.2020.153.12 ↗
11. Comparison between Gyko Inertial Sensor and Chronojump Contact Mat for the Assessment of Squat Jump, Countermovement Jump and Abalakov Jump in Amateur Male Volleyball Players, Amateur Male Rugby Players and in High School Students
12. A Proposed Method for Evaluating Drop Jump Performance with One Force Platform10.3390/biomechanics1020015 ↗
13. Comparisons of Laboratory-Based Methods to Calculate Jump Height and Improvements to the Field-Based Flight-Time Method10.1111/sms.13556 ↗
14. Concurrent Validity and Reliability of Proprietary and Open-Source Jump Mat Systems for the Assessment of Vertical Jumps in Sport Sciences
15. Validity of Vertical Jump Measurement Devices10.1080/02640414.2011.624539 ↗
16. Necessary Precautions in Measuring Correct Vertical Jumping Height by Means of Force Plate Measurements10.1080/00140130118100 ↗
17. Validity and Reliability of Methods for Testing Vertical Jumping Performance10.1123/jab.14.2.127 ↗
18. Inertial Sensors Are a Valid Tool to Detect and Consistently Quantify Jumping10.1055/s-0044-100793 ↗
19. Concurrent Validity and Reliability of Torso-Worn Inertial Measurement Unit for Jump Power and Height Estimation10.1080/02640414.2018.1426974 ↗
20. Held, S., Rappelt, L., Deutsch, J.-P., Donath, L., and Jimenez-Olmedo, M. (2021). Valid and Reliable Barbell Velocity Estimation Using an Inertial Measurement Unit. Int. J. Environ. Res. Public Health, 18.10.3390/ijerph18179170 ↗
21. Validation of Velocity Measuring Devices in Velocity Based Strength Training10.2478/ijcss-2021-0007 ↗
22. Fritschi, R., Seiler, J., and Gross, M. (2021). Validity and Effects of Placement of Velocity-Based Training Devices. Sports, 9.10.3390/sports9090123 ↗
23. Olovsson Stahl, E., and Öhrner, P. (2020). Concurrent Validity of an Inertial Sensor for Measuring Muscle Mechanical Properties, Umea Universitet.
24. Linnecke, T. (2022, September 19). How to Perform Jump Tests with Vmaxpro. Available online: https://vmaxpro.de/how-to-perform-jump-tests-with-vmaxpro/.
25. Defining Training and Performance Caliber: A Participant Classification Framework10.1123/ijspp.2021-0451 ↗
26. The Validity and Reliability of Counter Movement Jump Height Measured with the Polar Vantage V2 Sports Watch10.3389/fspor.2022.1013360 ↗
27. Simultaneous Measurement of Body Center of Pressure and Center of Gravity during Upright Stance. Part I: Methods10.1016/0966-6362(95)01030-0 ↗
28. García-Orea, G.P., Juan, R.H.E., Dalla-Vecchia, A.A., Pérez-Caballero, C., and Campillos, J.A. (2017). Vertical Jump Performance Measurement Devices and Techniques: What Options Do We Have?. Int. J. Phys. Exerc. Health Sci., 1.
29. Jump Height from Inertial Recordings: A Tutorial for a Sports Scientist10.1111/sms.13546 ↗
30. Read, M.M. (1997). The Effects of Varied Rest Interval Lengths on Depth Jump Performance, San Jose State University.
31. Effects of Countermovement Depth on Kinematic and Kinetic Patterns of Maximum Vertical Jumps10.1016/j.jelekin.2014.11.001 ↗
32. Vertical Jump Performance Is Affected by the Velocity and Depth of the Countermovement
33. Relevance of the Technique of Immobilizing Arms for the Kinetic Variables in the Countermovement Jump Test10.12800/ccd.v7i21.82 ↗
34. Statistical Methods in Assessing Agreement: Models, Issues, and Tools10.1198/016214502753479392 ↗
35. A Proposal for Strength-of-Agreement Criteria for Lin’s Concordance Correlation Coefficient
36. Correlation Coefficients10.1213/ANE.0000000000002864 ↗
37. Lake, J., Augustus, S., Austin, K., Mundy, P., McMahon, J., Comfort, P., and Haff, G. (2018). The Validity of the Push Band 2.0 during Vertical Jump Performance. Sports, 6.10.3390/sports6040140 ↗
38. Rago, V., Brito, J., Figueiredo, P., Carvalho, T., Fernandes, T., Fonseca, P., and Rebelo, A. (2018). Countermovement Jump Analysis Using Different Portable Devices: Implications for Field Testing. Sports, 6.10.3390/sports6030091 ↗
39. Comparison of Several Regression Procedures for Method Comparison Studies and Determination of Sample Sizes Application of Linear Regression Procedures for Method Comparison Studies in Clinical Chemistry, Part II
40. Progressive Statistics for Studies in Sports Medicine and Exercise Science10.1249/MSS.0b013e31818cb278 ↗
41. Strategies to Set Global Analytical Quality Specifications in Laboratory Medicine: 10 Years on from the Stockholm Consensus Conference10.1007/s00769-009-0630-8 ↗
42. Interpreting Method Comparison Studies by Use of the Bland-Altman Plot: Reflecting the Importance of Sample Size by Incorporating Confidence Limits and Predefined Error Limits in the Graphic10.1373/clinchem.2004.036095 ↗
43. Statistical Methods for Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine10.2165/00007256-199826040-00002 ↗
44. Reliability, Repeatability and Reproducibility: Analysis of Measurement Errors in Continuous Variables10.1002/uog.5256 ↗
45. Determining the Magnitude of Treatment Effects in Strength Training Research Through the Use of the Effect Size
46. Validity and Reliability of the WIMU Inertial Device for the Assessment of the Vertical Jump10.7717/peerj.4709 ↗
47. Novel Technologies Found to Be Valid and Reliable for the Measurement of Vertical Jump Height With Jump-and-Reach Testing10.1519/JSC.0000000000002790 ↗
48. Development and Evaluation of an Inertial Measurement Unit (IMU) System for Jump Detection and Jump Height Estimation in Beach Volleyball10.1007/s12662-022-00822-1 ↗
49. Measures of Reliability in Sports Medicine and Science10.2165/00007256-200030010-00001 ↗
50. Reliability and Validity of the Polar V800 Sports Watch for Estimating Vertical Jump Height
51. Validity and Reliability of the Output Sport Device for Assessing Drop Jump Performance
52. Validation of an Inertial Measurement Unit to Determine Countermovement Jump Height
53. Potential of IMU-Based Systems in Measuring Single Rapid Movement Variables in Females with Different Training Backgrounds and Specialization
54. Validity and Reliability of Portable Gym Devices and an IPhone App to Measure Vertical Jump Performance
55. Orser, K., Agar-Newman, D.J., Tsai, M.-C., and Klimstra, M. (2020). The Validity of the Push Band 2.0 to Determine Speed and Power during Progressively Loaded Squat Jumps. Sports Biomech., 1–9.10.1080/14763141.2020.1829691 ↗
56. Ripley, N., and Mcmahon, J.J. (2016, January 22). Validity and Reliability of the PUSH Wearable Device to Measure Velocity and Power During Loaded Countermovement Jumps. Proceedings of the NSCA 2016 Congress, New Orleans, LA, USA.
57. Validity and Reliability of Inertial Measurement Units for Jump Height Estimations: A Systematic Review10.5114/hm.2023.111548 ↗
58. Validation of an Inertial Measurement Unit for the Measurement of Jump Count and Height10.1016/j.ptsp.2016.12.001 ↗
59. The Reliability and Validity of the Bar-Mounted PUSH Band TM 2.0 during Bench Press with Moderate and Heavy Loads10.1080/02640414.2019.1656703 ↗
60. Understanding the Key Phases of the Countermovement Jump Force-Time Curve10.1519/SSC.0000000000000375 ↗
61. Weenk, D., Stevens, A.G., Koning, B.H., van Beijnum, B.J., Hermens, H.J., and Veltink, P.H. (2013, January 24–25). A Feasibility Study in Measuring Soft Tissue Artifacts on the Upper Leg Using Inertial and Magnetic Sensors. Proceedings of the 4th Dutch Bio-Medical Engineering Conference Sensors; BME, Egmond aan Zee, The Netherlands.
62. Miranda-Oliveira, P., Branco, M., and Fernandes, O. (2022). Accuracy of Inertial Measurement Units When Applied to the Countermovement Jump of Track and Field Athletes. Sensors, 22.10.3390/s22197186 ↗