journal article·2024-03-31Open access

Influence of Printing Angulation on the Accuracy (Trueness and Precision) of the Position of Implant Analogs in 3D Models: An In Vitro Pilot Study

Noelia García, Miguel Gómez-Polo, Miriam Fernández, José Luis Antonaya-Martín, Rocío Ortega, Cristina Gómez-Polo, Marta Revilla-León, Rocío Cascos

Applied Sciences· Volume 14· Issue 7

Abstract

Background: With CAD-CAM, dental models are often fabricated by additive manufacturing (AM) methods. Dental models for implant prostheses involve the manual placement of analogs, which could affect their final fit. Therefore, in this experimental in vitro study, the accuracy of the analogs’ position in models printed using AM methods was examined by comparing three different printing orientations. Methods: An STL file was obtained by scanning a master model with an implant placed in the maxillary left central incisor position. Three study groups (n = 10) with varying printing orientation parameters were obtained (0, 45, and 90 degrees). They were digitalized with a laboratory scanner and evaluated with an analysis metrology program. Differences between 3D datasets were measured using the RMS for trueness and SD RMS for precision. The data were statistically analyzed using the ANOVA test at a significance level of p < 0.05, followed by the Bonferroni post hoc test. Results: The 45-degrees group showed the best results. Regarding trueness, statistically significant differences were found between the 45- and 90-degrees groups (p < 0.005). In terms of precision, statistically significant differences appeared between the 45- and 0-degrees groups (p < 0.011) and between the 45- and 90-degrees groups (0.003). Conclusions: The printing angulation parameter affects the accuracy of 3D-printed models. Implant models manufactured at 45 degrees of printing angulation are more accurate than those printed at 0 or 90 degrees.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Anatomy and Medical Technology · Dental Implant Techniques and Outcomes · Surgical Simulation and Training

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Nursing and Estomatology, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, Spain

Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain

Dental Clinic Department, Faculty of Biomedical Sciences, European University of Madrid, 28670 Madrid, Spain

Department of Surgery, Faculty of Medicine, University of Salamanca, 37007 Salamanca, Spain

Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA 98195, USA

Kois Center, Seattle, WA 98109, USA

Department of Prosthodontics, School of Dental Medicine, Tufts University, Medford, MA 02155, USA

References (49)

Show source-provided references
1. The use of CAD/CAM in dentistry10.1016/j.cden.2011.02.011 ↗
2. Tensile properties and microstructures of laser-formed Ti-6Al-4V10.1007/s11665-010-9670-9 ↗
3. (2009). 2009 Standard Terminology for Additive Manufacturing—General Principles and Terminology. Committee F42 on Additive Manufacturing Technologies (Standard No. ISO/ASTM52900-15).
4. Accuracy of 3-dimensional computer-aided manufactured single-tooth implant definitive casts10.1016/j.prosdent.2018.02.011 ↗
5. CAD/CAM dental technology
6. Digital Dentistry—3D Printing Applications10.1515/jim-2017-0032 ↗
7. 3D printing in dentistry-state of the art10.2341/18-229-L ↗
8. Contemporary Evidence of CAD-CAM in Dentistry: A Systematic Review
9. Digital versus plaster study models: How accurate and reproducible are they?10.1179/1465312512Z.00000000023 ↗
10. Rosenstiel, S.F., Land, M.F., and Fujimoto, J. (2001). Contemporary Fixed Prosthodontics, Mosby. [3rd ed.].
11. A review of 3D printed in dentistry: Technologies, affecting factors and applications10.1155/2021/9950131 ↗
12. Intra-arch dimensional measurement validity of laser-scanned digital dental models compared with the original plaster models: A systematic review10.1111/ocr.12068 ↗
13. Position Accuracy of Implant Analogs on 3D Printed Polymer versus Conventional Dental Stone Casts Measured Using a Coordinate Measuring Machine
14. 3-Printing: The new industrial revolution10.1016/j.bushor.2011.11.003 ↗
15. The evolution of rapid prototyping in dentistry: A review10.1108/13552540910961946 ↗
16. 3D printing in dentistry10.1038/sj.bdj.2015.914 ↗
17. Current and Emerging Applications of 3D Printing in Restorative Dentistry10.1007/s40496-018-0181-3 ↗
18. Die spacer thickness reproduction for central incisor crown fabrication with combined computer-aided desing and 3D printing technologi¡y: An in vitro study10.1016/j.prosdent.2014.11.004 ↗
19. Advanced smile diagnostics using CAD/ CAM mock-ups
20. The future of dental devices is digital10.1016/j.dental.2011.10.014 ↗
21. In-process 3D geometry reconstruction of objects produced by direct light projection10.1007/s00170-013-4778-3 ↗
22. Development of a 3D printer using scanning projection stereolithography10.1038/srep09875 ↗
23. Influence of scan body design and digital implant analogs on implant replica position in additively manufactured casts10.1016/j.prosdent.2019.07.011 ↗
24. Revilla-León, M., Cascos-Sánchez, R., Zeitler, J.M., Barmak, A.B., Kois, J.C., and Gómez-Polo, M. (2023). Influence of print orientation and wet-dry storage time on the intaglio accuracy of additively manufactured occlusal devices. J. Prost. Dent.10.1016/j.prosdent.2022.12.005 ↗
25. Effect of build angle and layer height on the accuracy of 3-dimensional printed dental models10.1016/j.ajodo.2020.11.039 ↗
26. Fracture load of 3D-printed fixed dental prostheses compared with milled and conventionally fabricated ones: The impact of resin material, build direction, post-curing, and artificial aging-an in vitro study10.1007/s00784-019-02952-7 ↗
27. Accuracy of 3D printed models and implant-analog positions according to the implant-analog-holder offset, inner structure, and printing layer thickness: An in-vitro study10.1016/j.jdent.2022.104268 ↗
28. Influence of digital implant analog design on the positional trueness of an analog in additively manufactured models: An in-vitro study10.1111/cid.13137 ↗
29. Accuracy of Implant Analogs in 3D Printed Resin Models10.1111/jopr.13217 ↗
30. Influences of build angle on the accuracy, printing time, and material consumption of additively manufactured surgical templates10.1016/j.prosdent.2020.09.012 ↗
31. Unkovskiy, A., Schmidt, F., Beuer, F., Li, P., Spintzyk, S., and Kraemer Fernandez, P. (2021). Stereolithography vs. Direct Light Processing for Rapid Manufacturing of Complete Denture Bases: An In Vitro Accuracy Analysis. J. Clin. Med., 10.10.3390/jcm10051070 ↗
32. Light cursing strategies for lithography-based additive manufacturing of customized ceramics
33. Digital material fabrication using mask-image-projection-based stereolithography10.1108/13552541311312148 ↗
34. Effect of additive manufacturing process and storage condition on the dimensional accuracy and stability of 3D-printed dental casts10.1016/j.prosdent.2021.02.028 ↗
35. Alshaibani, R.M., Fan, Y., and Giordano, R. (2024). Effect of different storage conditions on dimensional accuracy of 3D-printed dental models. J. Prost.10.1111/jopr.13834 ↗
36. Joda, T., Matthisson, L., and Zitzmann, N.U. (2020). Impact of Aging on the Accuracy of 3D-Printed Dental Models: An In Vitro Investigation. J. Clin. Med., 9.10.3390/jcm9051436 ↗
37. Effects of post-curing conditions on mechanical properties of 3D printed clear dental aligners10.1108/RPJ-04-2019-0118 ↗
38. A study on the comparison mechanical properties of 3D printing prototypes with laminating direction
39. Passive Fit in Screw Retained Multi-unit Implant Prosthesis Understanding and Achieving: A Review of the Literature
40. Effects on build orientation on the mechanical properties of 3D-printed complete coverage interim dental restorations10.1016/j.prosdent.2015.12.002 ↗
41. Trueness and fitting accuracy of maxillary 3D printed complete dentures
42. Build Angle: Does It Influence the Accuracy of 3D-Printed Dental Restorations Using Digital Light-Processing Technology?10.11607/ijp.5117 ↗
43. Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing10.1016/j.prosdent.2020.04.028 ↗
44. Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models10.1016/j.ajodo.2017.06.012 ↗
45. Effect of print orientation and duration of ultraviolet curing on the dimensional accuracy of a 3-dimensionally printed orthodontic clear aligner design10.1016/j.ajodo.2020.03.023 ↗
46. Accuracy of Dental Replica Models Using Photopolymer Materials in Additive Manufacturing: In Vitro Three-Dimensional Evaluation
47. Accuracy and precision of polyurethane dental arch models fabricated using a threedimensional subtractive rapid prototyping method with an intraoral scanning technique10.4041/kjod.2014.44.2.69 ↗
48. New approach to accuracy verification of 3D surface models: An analysis of point cloud coordinates10.1016/j.jpor.2015.10.002 ↗
49. Czajkowska, M., Walejewska, E., Zadrożny, Ł., Wieczorek, M., Święszkowski, W., Wagner, L., Mijiritsky, E., and Markowski, J. (2020). Comparison of Dental Stone Models and Their 3D Printed Acrylic Replicas for the Accuracy and Mechanical Properties. Materials, 13.10.3390/ma13184066 ↗