2. Yi, Y., Heo, S.-J., Koak, J.-Y., and Kim, S.-K. (2021). Mechanical complications of implant-supported restorations with internal conical connection implants: A 14-year retrospective study. J. Prosthet. Dent., ahead-of-print.
10.1016/j.prosdent.2021.06.053 ↗3. Finite element analysis on dental implant-supported prostheses without passive fit
4. Bathe, K.J. (1996). Finite Element Procedures, Prentice-Hall. Chapter 4.
5. Gultekin, B.A., Gultekin, P., and Yalcin, S. (2012). Finite Element Analysis—New Trends and Developments, IntechOpen. [1st ed.].
6. Ebrahimi, F. (2012). Finite Element Analysis-New Trends and Developments, IntechOpen Ltd.
10.5772/3352 ↗8. Three-Dimensional Finite Element Analysis on stress distribution of internal Implant-Abutment engagement features
10.11607/jomi.5789 ↗9. A three-dimensional Finite Element Analysis of short Dental Implants in the posterior maxilla
10.11607/jomi.3210 ↗10. Comparative Evaluation of three abutment-implant interfeces on stress distribution in and around different implant systems: A Finite Element Analysis
10.4103/ccd.ccd_739_18 ↗11. Influence of Implant Connection Type on the Biomechanical Environment of Immediately Placed Implants—CT-Based Nonlinear, Three-Dimensional Finite Element Analysis
10.1111/j.1708-8208.2009.00155.x ↗12. Three-Dimensional Finite element analysis of the effect of endosteal implants with different maco designs on stress distribution in different bone qualities
10.11607/jomi.7058 ↗13. Influence of Abutment design on stress distribution in narrow implants with marginal bone loss: A Finite Element Analysis
10.11607/jomi.8554 ↗14. Three-Dimensional Finite Element Analysis of Different implant configurations in Enlarged first molar areas
10.11607/jomi.8143 ↗15. Comparative Finite Element Analysis of short implants with different treatment approaches in the atrophic mandible
10.11607/jomi.8122 ↗16. Static and Dynamic Stress Analysis of Standard- and Narrow-Diameter Implants: A 3D Finite Element Analysis
10.11607/jomi.8037 ↗17. Finite Element Method and Von Mises Investigation on Bone Response to Dynamic Stress with a Novel Conical Dental Implant Connection
18. Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant, A nonlinear finite element stress analysis
10.1034/j.1600-0501.2003.00828.x ↗19. Evaluation Using FEM on the Stress Distribution on the Implant, Prosthetic Components and Crown, with Cone Morse, External and Internal Hexagon Connections
20. Three-Dimensional Finite Element Analysis of the stress distribution at the internal Implant-Abutment connection
10.11607/prd.2351 ↗21. Maslucan, R.A., and Dominguez, J.A. (2022). A Finite Element Stress Analysis of a Conical Triangular Connection in Implants: A New Proposal. Materials, 15.
10.3390/ma15103680 ↗22. Three-dimensional Finite Element Analysis of varying diameter and connection type in implants with high crown-implant ratio
10.1590/0103-6440201801746 ↗23. Influence of tapered and external hexagon connections on bone stresses around tilted dental implants: Three-dimensional finite element method with statistical analysis
10.1902/jop.2013.120713 ↗25. Mechanics of the implant-abutment connection: An 8-degree taper compared to a butt joint connection
28. The effect of micromotion on the tissue response Influence of Implant-Abutment Connection on the Biomechanical Behavior of Implants 233 around immediately loaded roughened titanium implants in the rabbit
10.1111/j.1600-0722.2007.00416.x ↗30. The long-term efficacy of currently used dental implants: A review and proposed criteria of success
31. Biomechanics and Peri-implantisis: The effect of a subcrestal wing-thread to decrease alveolar crestal bone strain. Theory, Finite Element Analysis, and Clinical Application
10.11607/jomi.te63 ↗32. Selection of optimal dental implant diameter and length in type IV bone: A three-dimensional finite element analysis
10.1016/j.ijom.2009.07.001 ↗33. Laboratory ofLaboratory of Experimental Biology, Department of Anatomy, University of Gothenburg and the Department of Plastic Surgery, Sahlgrenska Sjukhuset, Gothenburg, Sweden Intra-osseous anchorage of dental prostheses. I. Experimental studies
34. Tissue reaction to an implant of a titanium hollow cylinder with a titanium surface spray layer
35. FEM and Von Mises Analysis of OSSTEM Dental Implant Structural Comoonents: Evalutation of Different Direction Dynamic Loads
10.2174/1874210601812010219 ↗37. Biology of biomechanics: Finite element analysis of a statically determinate system to rotate the occlusal plane for correction of a skeletal Class III open-bite malocclusion
10.1016/j.ajodo.2015.10.002 ↗38. Minimization of dental implant diameter and length according to bone quality determined by finite element analysis and optimized calculation
39. Stress Analysis Around Reduced-Diameter Zirconia and Titanium One-Piece Implants with and without microthreads in the neck: Experimental and Finite Element Analysis
10.11607/jomi.7419 ↗42. The Effect of Tapered and Cylindrical Implants on Stress Distribution In Different Bone Qualities: A Finite Element Analysis