journal article·2023-04-24Open access

Finite Element Analysis (FEA) for a Different Type of Cono-in Dental Implant

Caterina Callea, Mario Ceddia, Adriano Piattelli, Alessandro Specchiulli, Bartolomeo Trentadue

Applied Sciences· Volume 13· Issue 9

Abstract

The aim of biomechanics applied to implantology is to determine the deformative and tensional states by solving the equilibrium equations within the mandibular bone and the osseointegrated implant to ensure its stability and improve the success rate. The finite element method is a powerful numerical technique that uses computing power to derive approximate solutions for the analysis of components with very complex geometry, loads, materials, and especially the biomechanical problems analysis, which is challenging to find in vivo or in vitro. This study performs a complete FEA survey on 3 implants Cono-in with 3 different diameters 3.4 mm, 4.5 mm, and 5.2 mm with abutments inclined to 15° and evaluates the tensions that are generated in the system as a result of the application of chewing loads. In this study, the extent of the stresses developed in the peri-crestal zone of the implants with the variation of the occlusal overstress acting on them was also evaluated. Autodesk Inventor Nastran Software was used to perform this type of localized finite element analysis; With this type of analysis, it was possible to analyze the peri-crestal area of the implant more precisely through a more accurate reconstruction of the mesh element, which allowed us to solve the FEA solution mathematically. The results showed how the application of the inclined load with respect to the vertical load on a larger diameter system leads to an increase in stress.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Dental Radiography and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Mechanics, Mathematics and Management, Politecnico di Bari, 70125 Bari, Italy

School of Dentistry, Saint Camillus International University for Health and Medical Sciences (Unicamillus), 00131 Rome, Italy

Facultad de Medicina, UCAM, Universidad Catolica San Antonio de Murcia, 30107 Murcia, Spain

Dental School, University of Belgrade, 11000 Beograd, Serbia

Department of Medical, Dental and Biotechnological Sciences, University of Chieti-Pescara, Via dei Vestini 31, 66100 Chieti, Italy

Department of Engineering, Illinois Institute of Technology, 10 W 35th St., Chicago, IL 60616, USA

Department of Engineering, Northern University of Illinois, Northeast Illinois, 1425 W Lincoln Hwy, DeKalb, IL 60115, USA

References (43)

Show source-provided references
1. A Finite Element Analysis of Two Different Dental Implants: Stress Distribution in the Prosthesis, Abutment, Implant, and Supporting Bone10.1563/1548-1336(2008)34[1:AFEAOT]2.0.CO;2 ↗
2. Yi, Y., Heo, S.-J., Koak, J.-Y., and Kim, S.-K. (2021). Mechanical complications of implant-supported restorations with internal conical connection implants: A 14-year retrospective study. J. Prosthet. Dent., ahead-of-print.10.1016/j.prosdent.2021.06.053 ↗
3. Finite element analysis on dental implant-supported prostheses without passive fit
4. Bathe, K.J. (1996). Finite Element Procedures, Prentice-Hall. Chapter 4.
5. Gultekin, B.A., Gultekin, P., and Yalcin, S. (2012). Finite Element Analysis—New Trends and Developments, IntechOpen. [1st ed.].
6. Ebrahimi, F. (2012). Finite Element Analysis-New Trends and Developments, IntechOpen Ltd.10.5772/3352 ↗
7. 3D finite element analysis to detect stress distribution: Spiral family implants10.1007/s12663-009-0081-0 ↗
8. Three-Dimensional Finite Element Analysis on stress distribution of internal Implant-Abutment engagement features10.11607/jomi.5789 ↗
9. A three-dimensional Finite Element Analysis of short Dental Implants in the posterior maxilla10.11607/jomi.3210 ↗
10. Comparative Evaluation of three abutment-implant interfeces on stress distribution in and around different implant systems: A Finite Element Analysis10.4103/ccd.ccd_739_18 ↗
11. Influence of Implant Connection Type on the Biomechanical Environment of Immediately Placed Implants—CT-Based Nonlinear, Three-Dimensional Finite Element Analysis10.1111/j.1708-8208.2009.00155.x ↗
12. Three-Dimensional Finite element analysis of the effect of endosteal implants with different maco designs on stress distribution in different bone qualities10.11607/jomi.7058 ↗
13. Influence of Abutment design on stress distribution in narrow implants with marginal bone loss: A Finite Element Analysis10.11607/jomi.8554 ↗
14. Three-Dimensional Finite Element Analysis of Different implant configurations in Enlarged first molar areas10.11607/jomi.8143 ↗
15. Comparative Finite Element Analysis of short implants with different treatment approaches in the atrophic mandible10.11607/jomi.8122 ↗
16. Static and Dynamic Stress Analysis of Standard- and Narrow-Diameter Implants: A 3D Finite Element Analysis10.11607/jomi.8037 ↗
17. Finite Element Method and Von Mises Investigation on Bone Response to Dynamic Stress with a Novel Conical Dental Implant Connection
18. Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant, A nonlinear finite element stress analysis10.1034/j.1600-0501.2003.00828.x ↗
19. Evaluation Using FEM on the Stress Distribution on the Implant, Prosthetic Components and Crown, with Cone Morse, External and Internal Hexagon Connections
20. Three-Dimensional Finite Element Analysis of the stress distribution at the internal Implant-Abutment connection10.11607/prd.2351 ↗
21. Maslucan, R.A., and Dominguez, J.A. (2022). A Finite Element Stress Analysis of a Conical Triangular Connection in Implants: A New Proposal. Materials, 15.10.3390/ma15103680 ↗
22. Three-dimensional Finite Element Analysis of varying diameter and connection type in implants with high crown-implant ratio10.1590/0103-6440201801746 ↗
23. Influence of tapered and external hexagon connections on bone stresses around tilted dental implants: Three-dimensional finite element method with statistical analysis10.1902/jop.2013.120713 ↗
24. Finite element analysis on influence of implant surface treatments, connection and bone types10.1016/j.msec.2016.02.061 ↗
25. Mechanics of the implant-abutment connection: An 8-degree taper compared to a butt joint connection
26. Biomechanical factors affecting the bone dental implant interface10.1016/0267-6605(92)90049-Y ↗
27. Numerical simulation of tissue differentiation around loaded titanium implants in a bone chamber10.1016/j.jbiomech.2003.09.026 ↗
28. The effect of micromotion on the tissue response Influence of Implant-Abutment Connection on the Biomechanical Behavior of Implants 233 around immediately loaded roughened titanium implants in the rabbit10.1111/j.1600-0722.2007.00416.x ↗
29. Biomechanical aspects of bone-level diameter shifting at implant-abutment interface10.1097/ID.0b013e318198ffd1 ↗
30. The long-term efficacy of currently used dental implants: A review and proposed criteria of success
31. Biomechanics and Peri-implantisis: The effect of a subcrestal wing-thread to decrease alveolar crestal bone strain. Theory, Finite Element Analysis, and Clinical Application10.11607/jomi.te63 ↗
32. Selection of optimal dental implant diameter and length in type IV bone: A three-dimensional finite element analysis10.1016/j.ijom.2009.07.001 ↗
33. Laboratory ofLaboratory of Experimental Biology, Department of Anatomy, University of Gothenburg and the Department of Plastic Surgery, Sahlgrenska Sjukhuset, Gothenburg, Sweden Intra-osseous anchorage of dental prostheses. I. Experimental studies
34. Tissue reaction to an implant of a titanium hollow cylinder with a titanium surface spray layer
35. FEM and Von Mises Analysis of OSSTEM Dental Implant Structural Comoonents: Evalutation of Different Direction Dynamic Loads10.2174/1874210601812010219 ↗
36. The effect of thread pattern upon implant osseointegration10.1111/j.1600-0501.2009.01800.x ↗
37. Biology of biomechanics: Finite element analysis of a statically determinate system to rotate the occlusal plane for correction of a skeletal Class III open-bite malocclusion10.1016/j.ajodo.2015.10.002 ↗
38. Minimization of dental implant diameter and length according to bone quality determined by finite element analysis and optimized calculation
39. Stress Analysis Around Reduced-Diameter Zirconia and Titanium One-Piece Implants with and without microthreads in the neck: Experimental and Finite Element Analysis10.11607/jomi.7419 ↗
40. The influence of static an dynamic loading on marginal bone reactions around osseointegrated implants: An animal experimental study10.1034/j.1600-0501.2001.012003207.x ↗
41. Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys10.1034/j.1600-0501.1996.070208.x ↗
42. The Effect of Tapered and Cylindrical Implants on Stress Distribution In Different Bone Qualities: A Finite Element Analysis
43. Osseous adaption to continuous loading of rigid endosseous implants10.1016/0002-9416(84)90301-4 ↗