journal article·2021-10-23Open access

Electrochemically Activated Screen-Printed Carbon Electrode for Determination of Ibuprofen

Katarzyna Tyszczuk-Rotko, Jędrzej Kozak, Anna Węzińska

Applied Sciences· Volume 11· Issue 21

Abstract

In this study, we present a simple, sensitive and selective analytical procedure for the ibuprofen (IBP) analysis using the commercially available screen-printed carbon electrode electrochemically activated (aSPCE) by cyclic voltammetry in 0.1 M NaOH. The quantitative determinations of IBP were carried out in 0.25 M acetate buffer solution of pH 4.5 ± 0.1 using the differential-pulse voltammetry (DPV). Different experimental parameters for DPV analysis were optimized, including pH and concentration of supporting electrolyte, amplitude (ΔEA), scan rate (ν) and modulation time (tm). The linear ranges of calibration curve were from 0.50–20.0 and 20.0–500.0 µM. The detection and quantification limits were estimated to be 0.059 and 0.20 µM. The aSPCE displayed satisfactory repeatability, reproducibility, and selectivity. Furthermore, the DPV procedure with the use of aSPCE was used to determination of IBP in pharmaceutical formulations. The results achieved by DPV show satisfactory agreement with those obtained by manufacturers (the relative errors are in the range of 3.1–4.7%).
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Analytical Methods in Pharmaceuticals · Pharmacological Effects and Assays

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University, 20-031 Lublin, Poland

References (17)

Show source-provided references
1. Determination of ibuprofen in human plasma and urine by gas chromatography/mass spectrometry10.5740/jaoacint.11-414 ↗
2. Simultaneous determination of ibuprofen and caffeine in urine samples by combining MCR-ALS and excitation-emission data
3. Development of a nano-SiO2 based enzyme-linked ligand binding assay for the determination of ibuprofen in human urine10.1016/j.talanta.2017.03.011 ↗
4. An overview of clinical pharmacology of ibuprofen10.5001/omj.2010.49 ↗
5. Development and validation of a liquid chromatography-tandem mass spectrometry method for determination of ibuprofen in human plasma10.1016/j.clinms.2019.10.002 ↗
6. Determination of ibuprofen and paraben in pharmaceutical formulations using flow-injection and derivative spectrophotometry10.1134/S1061934815010141 ↗
7. Development and Validation of an HPLC Method for Simultaneous Determination of Ibuprofen and 17 Related Compounds10.1007/s10337-017-3358-3 ↗
8. A rapid and sensitive reversed phase-HPLC method for simultaneous determination of ibuprofen and paracetamol in drug samples and their behaviors in simulated gastric conditions10.1002/jssc.201801002 ↗
9. Application of capillary zone electrophoresis coupled with a diode array detector (CZE-DAD) for simultaneous analysis of ibuprofen and phenylephrine10.5740/jaoacint.18-0134 ↗
10. An advanced approach for electrochemical sensing of ibuprofen in pharmaceuticals and human urine samples using a bare boron-doped diamond electrode10.1016/j.jelechem.2018.05.026 ↗
11. Electrocatalytic effect of Al2O3 supported on clay in oxidizing of ibuprofen at graphite electrode10.17721/moca.2021.81-87 ↗
12. Determination of ibuprofen based on screen-printed electrodes modified with carbon nanofibers
13. Commercial screen-printed electrodes based on carbon nanomaterials for a fast and cost-effective voltammetric determination of paracetamol, ibuprofen and caffeine in water samples10.3390/s19184039 ↗
14. Disposable screen printed graphite electrode for the directelectrochemical determination of ibuprofen in surface water
15. Kozak, J., Tyszczuk-Rotko, K., Wójciak, M., Sowa, I., and Rotko, M. (2021). First screen-printed sensor (electrochemically activated screen-printed boron-doped diamond electrode) for quantitative determination of rifampicin by adsorptive stripping voltammetry. Materials, 14.10.3390/ma14154231 ↗
16. Methodological approach to determine carlina oxide—A main volatile constituent of Carlina acaulis L. essential oil10.1016/j.talanta.2018.09.005 ↗
17. A statistical overview of standard (IUPAC and ACS) and new procedures for determining the limits of detection and quantification: Application to voltammetric and stripping techniques10.1351/pac199769020297 ↗