Development and Application of a Motion Analysis Protocol for the Kinematic Evaluation of Basic and Functional Hand and Finger Movements Using Motion Capture in a Clinical Setting—A Repeatability Study
Source abstract
Abstract
The purpose of this study was to develop a motion analysis protocol that allows the simultaneous assessment of all hand and finger joint movements. The objective was to demonstrate repeatability for future clinical applications in functional assessments. This study includes selection of marker positions, movement tasks, kinematic approaches and a comparison of the two most commonly used finger marker sets. By using a test–retest measurement of the range of motion in twenty healthy volunteers, the repeatability of the developed protocol was validated. Estimated errors of the presented method ranged from 1.2° to 6.4°. Finger joint angles derived from the marker set with two markers per segment showed better repeatability (3.7°) than with markers located on the joints (5.1°). Given the high repeatability found, the presented method appears to be suitable for clinical applications. For the fingers, measurement repeatability can be improved by using at least two markers per segment. Within this study, advanced kinematic approaches, such as functional determination of joint centers and axes, are applied to the analysis of hand movements. The provided standard values and estimate of the minimal detectable differences provide a valuable basis for meaningful data interpretation and may be used for future comparison with other protocols.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Shoulder Injury and Treatment · Orthopedic Surgery and Rehabilitation · Nerve Injury and Rehabilitation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Division of Plastic Surgery and Hand Surgery, University Hospital Zurich, University of Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
Institute for Biomechanics, ETH Zurich, Leopold-Ruzicka-Weg 4, 8093 Zürich, Switzerland
Biomechanics Research Laboratory, University of Wollongong, Northfields Avenue, Wollongong, NSW 2522, Australia
Human Performance Lab, Schulthess Clinic, Zurich, Lengghalde 2, 8008 Zürich, Switzerland
References (32)
Show source-provided references
1. Movement biomechanics goes upwards: From the leg to the arm10.1016/S0021-9290(00)00062-2 ↗
2. Marker placement to describe the wrist movement during activities of daily living in cyclical tasks10.1016/j.clinbiomech.2003.11.012 ↗
3. A framework for the definition of standardized protocols for measuring upper-extremity kinematics10.1016/j.clinbiomech.2008.12.009 ↗
4. Comparison of three local frame definitions for the kinematic analysis of the fingers and the wrist10.1016/j.jbiomech.2014.05.025 ↗
5. Assessment of hand function during activities of daily living using motion tracking cameras: A systematic review10.1177/0954411919851302 ↗
6. Finger kinematic modeling and real-time hand motion estimation10.1007/s10439-007-9364-0 ↗
7. Review of arm motion analyses10.1243/0954411001535570 ↗
8. Validation and application of a computational model for wrist and hand movements using surface markers10.1109/TBME.2007.908087 ↗
9. A novel method for in-vivo evaluation of finger kinematics including definition of healthy motion patterns10.1016/j.clinbiomech.2015.10.002 ↗
10. Quantitative comparison of marker attachment methods for hand motion analysis10.1080/10803548.2015.1017960 ↗
11. Experimental protocol for the kinematic analysis of the hand: Definition and repeatability10.1016/j.gaitpost.2005.05.001 ↗
12. A demonstration of the validity of a 3-D video motion analysis method for measuring finger flexion and extension10.1016/S0021-9290(99)00140-2 ↗
13. Validity of a simple videogrammetric method to measure the movement of all hand segments for clinical purposes10.1177/0954411914522023 ↗
14. Three-dimensional rotations of human three-joint fingers: An optoelectronic measurement. Preliminary results10.1007/s00276-004-0277-4 ↗
15. A technique for motion capture of the finger using functional joint centres and the effect of calibration range of motion on its accuracy10.1177/0954411912442133 ↗
16. Murphy, M., Sunnerhagen, K., Johnels, B., and Willén, C. (2006). Three-dimensional kinematic motion analysis of a daily activity drinking from a glass: A pilot study. J. Neuro Eng. Rehabil., 3.10.1186/1743-0003-3-18 ↗
17. Gander, W., and Hrebicek, J. (1997). Least squares fit of point clouds. Solving Problems in Scientific Computing Using Maple and MATLAB®, Springer. [3rd ed.].10.1007/978-3-642-97953-8 ↗
18. Modified kinematic technique for measuring pathological hyperextension and hypermobility of the interphalangeal joints10.1109/TBME.2011.2106126 ↗
19. A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee10.1115/1.3138397 ↗
20. ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion—Part II: Shoulder, elbow, wrist and hand10.1016/j.jbiomech.2004.05.042 ↗
21. Kinematics of the trunk and the lower extremities during restricted and unrestricted squats10.1519/JSC.0b013e3182736034 ↗
22. 3-D attitude representation of human joints: A standardization proposal10.1016/0021-9290(94)90191-0 ↗
23. When to use agreement versus reliability measures10.1016/j.jclinepi.2005.10.015 ↗
24. Use of the standard error as a reliability index of interest: An applied example using elbow flexor strength data10.1093/ptj/77.7.745 ↗
25. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM
26. The reliability of three-dimensional kinematic gait measurements: A systematic review10.1016/j.gaitpost.2008.09.003 ↗
27. Analysis of skin movement with respect to flexional bone motion using MR images of a hand10.1016/j.jbiomech.2005.02.001 ↗
28. Quantifying soft tissue artefacts and imaging variability in motion capture of the fingers10.1007/s10439-020-02476-2 ↗
29. Impact of simulated proximal interphalangeal arthrodeses of all fingers on hand function10.1016/j.jhsa.2006.03.008 ↗
30. A normative database of thumb circumduction in vivo: Center of rotation and range of motion10.1518/001872005774860069 ↗
31. Three-dimensional metacarpophalangeal joint kinematics using two markers on the phalanx10.1243/0954411011535993 ↗
32. Minimal detectable difference of the finger and wrist range of motion: Comparison of goniometry and 3D motion analysis10.1186/s13018-019-1177-y ↗