The Interplay between Air Quality and Energy Efficiency in Museums, a Review
Source abstract
Abstract
Energy efficiency in museums and buildings that house works of art or cultural heritage appears to be a difficult achievement if indoor air quality has to be kept at appropriate levels for artefacts’ long-term sustainability. There is a gap in our scientific literature on the relationship between indoor air quality and energy efficiency, meaning that there are no numerical data that examine both of them simultaneously, although this is a theme that is broadly discussed by museum managers, curators, and scientists. It is certain that the two parameters, indoor air quality (IAQ) and energy efficiency (EEF) are conflicting and difficult to reconcile. Furthermore, IAQ is not only the determination of temperature, relative humidity, and CO2, as is usually presented. Using green or renewable energy does not make a building “energy efficient”. Hence, in the manuscript we review the literature on IAQ of museums and exhibition buildings, in conjunction with the consideration of their EEF. Hopefully, reviewing the literature for this problem may lead to carefully designed monitoring experiments. The selection, application, and testing of appropriate technological measures can lead to a new balance between the two conflicting parameters. Not only must solutions be found, but these solutions are necessary in the mitigation battle against climate change.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Conservation Techniques and Studies · Building materials and conservation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Laboratory of Atmospheric Pollution and Pollution Control Engineering of Atmospheric Pollutants, Department of Environmental Engineering, Faculty of Engineering, Democritus University of Thrace, 67100 Xanthi, Greece
Unit of Environmental and Networking Technologies and Applications ATHENA-RIC, University Campus, Kimmeria, 67100 Xanthi, Greece
References (100+)
Show source-provided references
1. IPCC (2021). Climate Change 2021: The Physical Science Basis, Cambridge University Press.
2. Thomson, G. (1978). The Museum Environment, Butterworths.
3. Some aspects of the conservation of works of art in buildings of new concrete10.1179/sic.1975.20.2.010 ↗
4. Indoor air pollution: Effects on cultural and historic materials10.1016/0260-4779(85)90049-4 ↗
5. Relative humidity and the stress/strain response of canvas paintings: Uniaxial measurements of naturally aged samples10.1179/sic.1988.33.3.133 ↗
6. The composition of museum atmospheres10.1016/0957-1272(90)90003-D ↗
7. Numerical simulation of indoor air pollution levels in a church and in a museum in Greece10.1179/sic.2000.45.2.85 ↗
8. Environmental parameters in museums10.1016/S0360-1323(03)00113-6 ↗
9. Tétreault, J. (2003). Airborne Pollutants in Museums, Galleries and Archives: Risk Assessment, Control Strategies and Preservation Management, Canadian Conservation Institute.
10. Volatile organic compounds from wood and their influences on museum artifact materials I. Differences in wood species and analyses of causal substances of deterioration10.1007/s10086-004-0654-y ↗
11. Indoor microclimate, ozone and nitrogen oxides in two medieval churches in Cyprus10.1016/j.atmosenv.2006.07.015 ↗
12. Indoor air pollution in museums: Prediction models and control strategies10.1179/sic.2006.51.Supplement-1.27 ↗
13. Assessment of aerosol particles within the Rubens’ House Museum in Antwerp, Belgium
14. Air quality in archives housed in historic buildings: Assessment of concentration of indoor particles of outdoor origin10.1016/j.buildenv.2020.107024 ↗
15. “La Specola” Museum in Florence: Environmental Monitoring and Building Energy Simulation10.1016/j.prostr.2020.11.134 ↗
16. Assessment of indoor air quality for a better preventive conservation of some French museums and monuments10.1007/s11356-020-10257-6 ↗
17. Ilieș, D.C., Marcu, F., Caciora, T., Indrie, L., Ilieș, A., Albu, A., Costea, M., Burtă, L., Baias, Ș., and Ilieș, M. (2021). Investigations of Museum Indoor Microclimate and Air Quality. Case Study from Romania. Atmosphere, 12.10.3390/atmos12020286 ↗
18. Camuffo, D. (2019). Microclimate for Cultural Heritage: Measurement, Risk Assessment, Conservation, Restoration, and Maintenance of Indoor and Outdoor Monuments, Elsevier.
19. Energy consumption, thermal comfort, and indoor air quality in mosques: Impact of Covid-19 measures10.1016/j.jclepro.2022.131726 ↗
20. Interactions of climate change, air pollution, and human health10.1007/s40572-018-0188-x ↗
21. Exploring the consequences of climate change for indoor air quality10.1088/1748-9326/8/1/015022 ↗
22. A holistic modeling framework for estimating the influence of climate change on indoor air quality10.1111/ina.13039 ↗
23. Modeling global residential sector energy demand for heating and air conditioning in the context of climate change10.1016/j.enpol.2008.09.051 ↗
24. Energy efficiency—Indoor air quality dilemma in public buildings10.1016/j.egypro.2018.07.115 ↗
25. Kakoulli, C., Kyriacou, A., and Michaelides, M.P. (2022). A Review of Field Measurement Studies on Thermal Comfort, Indoor Air Quality and Virus Risk. Atmosphere, 13.10.3390/atmos13020191 ↗
26. UNESCO (2020). Museums around the World, De Gruyter Saur. [26th ed.].
27. Climate for Culture: Assessing the impact of climate change on the future indoor climate in historic buildings using simulations10.1186/s40494-015-0067-9 ↗
28. Indoor particulate matter in four Belgian heritage sites: Case studies on the deposition of dark-colored and hygroscopic particles10.1016/j.scitotenv.2014.11.018 ↗
29. Preventive conservation strategies for sustainable urban pollution control in museums10.1179/sic.2000.45.Supplement-1.24 ↗
30. Corrosive effects from the deposition of gaseous pollutants on surfaces of cultural and artistic value inside museums10.1016/S0304-3894(98)00241-6 ↗
31. Tétreault, J. (2021). Control of Pollutants in Museums and Archives–Technical Bulletin 37.
32. Cassar, M., Blades, N., and Oreszczyn, T. (September, January 29). Air pollutant levels in air-conditioned and naturally ventilated museums: A pilot study. Proceedings of the International Council of Museum (ICOM) 12th Triennial Meeting, Lyon, France. Available online: https://discovery.ucl.ac.uk/id/eprint/2274/.
33. Blades, N., Oreszczyn, T., Bordass, B., and Cassar, M. (2000). Guidelines on Pollution Control in Heritage Buildings, UCL. Technical Report.
34. Brophy, S.S., and Wylie, E. (2013). The Green Museum: A Primer on Environmental Practice, Altamira Press.
35. Green building education in the green museum: Design strategies in eight case study museums10.1080/21548455.2020.1723182 ↗
36. Evolving climate change policy and museums10.1080/09647775.2020.1844589 ↗
37. Theoretical model for relating indoor pollutant concentrations to those outside10.1021/es60090a006 ↗
38. Mathematical modeling of chemically reactive pollutants in indoor air10.1021/es00151a012 ↗
39. Review of relationship between indoor and outdoor particles: I/O ratio, infiltration factor and penetration factor10.1016/j.atmosenv.2010.09.048 ↗
40. The atmospheric chemistry of indoor environments10.1039/C9EM00386J ↗
41. Determining the infiltration of outdoor particles in the indoor environment using a dynamic model10.1016/j.jaerosci.2005.05.020 ↗
42. Time-Resolved Measurements of Indoor Chemical Emissions, Deposition, and Reactions in a University Art Museum10.1021/acs.est.9b00276 ↗
43. Control strategies for sub-micrometer particles indoors: Model study of air filtration and ventilation10.1034/j.1600-0668.2003.00184.x ↗
44. Estimating the concentration of indoor particles of outdoor origin: A review10.1080/10962247.2013.791649 ↗
45. Emmerich, S.J., and Persily, A.K. (2003). State-of-the-Art Review of CO2 Demand Controlled Ventilation Technology and Application, Diane Publishing Co.
46. Indoor/outdoor PM2.5 elemental composition and organic fraction medications, in a Greek hospital10.1016/j.scitotenv.2016.01.070 ↗
47. Organic compounds as indicators of air pollution10.1034/j.1600-0668.13.s.6.2.x ↗
48. Dabanlis, G., Loupa, G., Liakos, D., and Rapsomanikis, S. (2022). The Effect of Students, Computers, and Air Purifiers on Classroom Air Quality. Appl. Sci., 12.10.3390/app122311911 ↗
49. Fragrances and Aerosol during Office Cleaning10.4209/aaqr.2017.08.0270 ↗
50. Chemicals in European residences—Part I: A review of emissions, concentrations and health effects of volatile organic compounds (VOCs)10.1016/j.scitotenv.2022.156201 ↗
51. Chiantore, O., and Poli, T. (2021). Indoor Air Quality in Museum Display Cases: Volatile Emissions, Materials Contributions, Impacts. Atmosphere, 12.10.3390/atmos12030364 ↗
52. Potential effects of particulate matter from combustion during services on human health and on works of art in medieval churches in Cyprus10.1016/j.envpol.2010.06.005 ↗
53. Indoor environmental quality index for conservation environments: The importance of including particulate matter10.1016/j.buildenv.2017.09.022 ↗
54. Indoor air quality in sustainable, energy efficient buildings10.1080/10789669.2011.592106 ↗
55. Perspectives of naturally ventilated buildings: A review10.1016/j.rser.2020.109933 ↗
56. Lighting in museums: Lighting interventions during the European demonstration project ‘Energy efficiency and sustainability in retrofitted and new museum buildings’(NNES-1999-20)10.1080/14786450600921546 ↗
57. Grzywacz, C.M. (2006). Monitoring for Gaseous Pollutants in Museum Environments, Getty Publications.
58. Cass, G.R., Druzik, J.R., Grosjean, D., Nazaroff, W.W., Whitmore, P.M., and Wittman, C.L. (1989). Protection of Works of Art from Atmospheric Ozone, Getty Publications.
59. PM2.5 and associated ionic component concentrations inside the archaeological museum of Thessaloniki, N. Greece10.1016/j.atmosenv.2004.04.034 ↗
60. Nazaroff, W.W. (1993). Airborne Particles in Museums, Getty Publications.
61. Wold Health Organization (2021). WHO Global Air Quality Guidelines: Particulate Matter (PM2.5 and PM10), Ozone, Nitrogen Dioxide, Sulfur Dioxide and Carbon Monoxide, WHO.
62. The indoor environment of a modern museum building, the Sainsbury Centre for Visual Arts, Norwich, UK10.1111/j.1600-0668.1999.t01-1-00002.x ↗
63. Indoor air quality at the Correr Museum, Venice, Italy10.1016/S0048-9697(99)00262-4 ↗
64. Sulfur dioxide, hydrogen sulfide, total reduced sulfur, chlorinated hydrocarbons and photochemical oxidants in southern California museums10.1016/0960-1686(91)90009-V ↗
65. Indoor Ozone and Nitrogen Dioxide Concentration in Two Museums of the São Paulo Megacity–Brazil
66. Particulate matter in the indoor environment of museums in the megacity of São Paulo
67. Determination of some atmospheric pollutants inside a museum: Relationship with the concentration outside10.1016/0048-9697(92)90504-L ↗
68. Characteristics of fine particulate matter (PM(2.5)) at Jinsha Site Museum, Chengdu, China10.1007/s11356-021-15743-z ↗
69. Indoor air quality at five site museums of Yangtze River civilization10.1016/j.atmosenv.2015.10.022 ↗
70. Assessment of the air quality (NO2, SO2, O3 and particulate matter) in the Plantin-Moretus Museum/Print Room in Antwerp, Belgium, in different seasons of the year10.1016/j.microc.2011.11.008 ↗
71. Studying the indoor air quality in three non-residential environments of different use: A museum, a printery industry and an office10.1016/j.buildenv.2011.05.013 ↗
72. Saridaki, A., Glytsos, T., Raisi, L., Katsivela, E., Tsiamis, G., Kalogerakis, N., and Lazaridis, M. (2022). Airborne particles, bacterial and fungal communities insights of two museum exhibition halls with diverse air quality characteristics. Aerobiologia.10.1007/s10453-022-09775-2 ↗
73. Measurement of particulate matter in a heritage building using optical counters: Long-term and spatial analyses10.1016/j.scitotenv.2022.160747 ↗
74. Indoor air quality evaluation of two museums in a subtropical climate conditions10.1016/j.scs.2015.10.002 ↗
75. Watt, J., Tidblad, J., Kucera, V., and Hamilton, R. (2009). The Effects of Air Pollution on Cultural Heritage, Springer.
76. Characterizing particulate pollutants in an enclosed museum in Shanghai, China10.4209/aaqr.2013.12.0360 ↗
77. Evaluation of indoor air quality in a museum (Bait Al Zubair) and residential homes10.1177/1420326X13508968 ↗
78. The measurement and model predictions of indoor ozone concentrations in museums10.1016/0960-1686(90)90513-M ↗
79. The regulations and reality of indoor environmental standards for objects and visitors in museums10.1016/j.rser.2021.111653 ↗
80. Viable Airborne and Deposited Microorganisms inside the Historical Museum of Crete10.4209/aaqr.200649 ↗
81. Assessment of the impact of particulate dry deposition on soiling of indoor cultural heritage objects found in churches and museums/libraries10.1016/j.culher.2019.02.017 ↗
82. Assessing the impact of vehicular particulate matter on cultural heritage by magnetic biomonitoring at Villa Farnesina in Rome, Italy10.1016/j.scitotenv.2022.153729 ↗
83. Emission rates and the personal cloud effect associated with particle release from the perihuman environment10.1111/ina.12365 ↗
84. Walking-induced particle resuspension in indoor environments10.1016/j.atmosenv.2014.02.035 ↗
85. Loupa, G., Karali, D., and Rapsomanikis, S. (2020). Aerosol filtering efficiency of respiratory face masks used during the COVID-19 pandemic. medRxiv.10.1101/2020.07.16.20155119 ↗
86. Human breath emissions of VOCS10.1080/10473289.1999.10463831 ↗
87. Indoor Secondary Pollutants from Household Product Emissions in the Presence of Ozone: A Bench-Scale Chamber Study10.1021/es052198z ↗
88. Impact of vacuum cleaning on indoor air quality10.1016/j.buildenv.2020.107059 ↗
89. The Evolution of Specifications for Limiting Pollutants in Museums and Archives
90. Indoor air quality of a museum in a subtropical climate: The Oscar Niemeyer museum in Curitiba, Brazil10.1016/j.scitotenv.2013.02.070 ↗
91. Air pollution in Southern California museums: Indoor and outdoor levels of nitrogen dioxide, peroxyacetyl nitrate, nitric acid, and chlorinated hydrocarbons10.1021/es00017a004 ↗
92. Chlorinated paraffins in the indoor and outdoor atmospheric particles from the Pearl River Delta: Characteristics, sources, and human exposure risks10.1016/j.scitotenv.2018.09.107 ↗
93. Comparative study of air-conditioned and non air-conditioned museums10.1179/sic.1994.39.Supplement-2.144 ↗
94. Heating Accounts For 70% of Museum’s Energy Savings
95. Environmental monitoring in four European museums10.1016/S1352-2310(01)00088-7 ↗
96. Indoor environment and conservation in the royal museum of fine arts, Antwerp, Belgium10.1016/j.culher.2004.02.002 ↗
97. Indoor environment quality in the museum building and its effect on heating and cooling demand10.1016/j.enbuild.2014.09.014 ↗
98. Bernardi, E., Carlucci, S., Cornaro, C., and Bohne, R.A. (2017). An analysis of the most adopted rating systems for assessing the environmental impact of buildings. Sustainability, 9.10.3390/su9071226 ↗
99. Indoor air quality investigation before and after relocation to WELL-certified office buildings10.1016/j.buildenv.2021.108182 ↗
100. Energy Efficiency in Heritage Buildings—Future Challenges and Research Needs10.1179/1756750514Z.00000000058 ↗