Development of a Generic Numerical Transtibial Model for Limb–Prosthesis System Evaluation
Source abstract
Abstract
The well-established finite element method (FEM) has been used successfully to evaluate and develop medical devices for lower-limb prosthetics over recent decades. Most numerical models are based on a specific 3D geometry, which, although allowing for an accurate analysis of a specific case, may differ significantly from the target group that is often geometrically closer to the average residual limb. In order to address this issue, a generic numerical transtibial model was developed with the corresponding definitive socket and silicone liner. Three load cases were performed to analyse the applicability of the model: donning, single-leg stance, and the static P5 test according to ISO 10328. While the first two cases were used commonly in previous studies, the ISO test was only used in physical tests and not in a numerical environment. The results of the simulations in terms of contact pressure, as well as the relative deformation of the socket, fit into the range reported in the literature for similar boundary conditions, thus verifying the model in biomechanical terms. The generic transtibial model serves as a numerical tool for the relative comparison of different socket-liner designs prior to the fabrication, providing insights into results that are otherwise difficult to obtain.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Prosthetics and Rehabilitation Robotics · Muscle activation and electromyography studies · Soft Robotics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Laboratory for Intelligent CAD Systems, Faculty of Mechanical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia
Funding
Slovenian Research Agency
References (42)
Show source-provided references
1. Lower Limb Major Amputation Data as a Signal of an East/West Health Divide Across Europe10.1016/j.ejvs.2020.07.051 ↗
2. Sockets for Limb Prostheses: A Review of Existing Technologies and Open Challenges10.1109/TBME.2017.2775100 ↗
3. Krajbich, J.I., Pinzur, M.S., Potter, B.K., and Stevens, P.M. (2016). Atlas of Amputations and Limb Deficiencies: Surgical, Prosthetic, and Rehabilitation Principles, Lippincott Williams & Wilkins. [4th ed.].
4. Use and satisfaction with prosthetic limb devices and related services10.1016/j.apmr.2003.06.002 ↗
5. Cagle, J. (2016). A Computational Tool to Enhance Clinical Selection of Prosthetic Liners for People with Lower Limb Amputation. [Ph.D. Thesis, University of Washington].
6. 3D interactive environment for the design of medical devices10.1007/s12008-018-0458-8 ↗
7. Analysis of compression/release stabilized transfemoral prosthetic socket by finite element modelling method10.1016/j.medengphy.2020.05.007 ↗
8. Predictive prosthetic socket design: Part 1—Population-based evaluation of transtibial prosthetic sockets by FEA-driven surrogate modelling10.1007/s10237-019-01195-5 ↗
9. Moerman, K., Sengeh, D., and Herr, H. (2016). Automated and Data-driven Computational Design of Patient-Specific Biomechanical Interfaces. Germany, Europe. engrXiv.10.31224/osf.io/g8h9n ↗
10. Finite element analysis of the amputated lower limb: A systematic review and recommendations10.1016/j.medengphy.2017.02.008 ↗
11. Silver-Thorn, M.B. (1991). Prediction and Experimental Verification of Residual Limb/Prosthetic Socket Interface Pressures for Below-Knee Amputees. [Ph.D. Thesis, Northwestern University].
12. Predicting Knee Joint Instability Using a Tibio-Femoral Statistical Shape Model10.3389/fbioe.2020.00253 ↗
13. Three-dimensional Morphology of the Knee Reveals Ethnic Differences10.1007/s11999-011-2089-2 ↗
14. Generic, geometric finite element analysis of the transtibial residual limb and prosthetic socket
15. Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation
16. Identification of pressure distribution at the socket interface of an above-knee prosthesis10.1016/S0965-9978(96)00048-8 ↗
17. Nonlinear Elastic Material Property Estimation of Lower Extremity Residual Limb Tissues10.1109/TNSRE.2003.810436 ↗
18. Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: A new tool for prosthetic fitting10.1007/s10439-006-9208-3 ↗
19. Development of a preliminary finite element model to assess the effects of friction on the residual limb of a transfemoral amputee10.1016/j.matpr.2020.05.199 ↗
20. Predictive prosthetic socket design: Part 2—Generating person-specific candidate designs using multi-objective genetic algorithms10.1007/s10237-019-01258-7 ↗
21. Characterising Residual Limb Morphology and Prosthetic Socket Design Based on Expert Clinician Practice10.3390/prosthesis3040027 ↗
22. TLEM 2.0–A comprehensive musculoskeletal geometry dataset for subject-specific modeling of lower extremity10.1016/j.jbiomech.2014.12.034 ↗
23. Anthropometric reference data for children and adults: United States, 2003
24. Kapandji, I.A. (1987). The Physiology of the Joints: Lower Limb, Churchill Livingstone.
25. Characterization of prosthetic liner products for people with transtibial amputation10.1097/JPO.0000000000000205 ↗
26. Silver-Thorn, M.B., Tonuk, E., and Kemp, J. (1999, January 13–16). In vivo indentation of lower extremity limb soft tissues. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology, Atlanta, GA, USA.
27. Kallin, S., Rashid, A., Salomonsson, K., and Hansbo, P. (2019). Comparison of mechanical conditions in a lower leg model with 5 or 6 tissue types while exposed to prosthetic sockets applying finite element analysis. arXiv.
28. A finite element model to assess transtibial prosthetic sockets with elastomeric liners10.1007/s11517-017-1758-z ↗
29. Mechanical testing of laminated composite materials for prosthetic sockets
30. Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket10.1016/j.medengphy.2004.04.010 ↗
31. (2016). Standard No. EN ISO 10328:2016 E.
32. Comparison of computational analysis with clinical measurement of stresses on below-knee residual limb in a prosthetic socket10.1016/S1350-4533(00)00079-5 ↗
33. Finite element estimates of interface stress in the trans-tibial prosthesis using gap elements are different from those using automated contact10.1016/S0021-9290(00)00022-1 ↗
34. A proposal for the pre-evaluation protocol of below-knee socket design—Integration pain tolerance with finite element analysis10.1080/02533839.2003.9670840 ↗
35. Load transfer mechanics between trans-tibial prosthetic socket and residual limb—Dynamic effects10.1016/j.jbiomech.2003.12.024 ↗
36. Dynamic interface pressure distributions of two transtibial prosthetic socket concepts10.1682/JRRD.2008.01.0015 ↗
37. Prosthetic limb sockets from plant-based composite materials10.1177/0309364611434568 ↗
38. Structural integrity of polypropylene prosthetic sockets manufactured using the polymer deposition technique10.1243/095441102321032157 ↗
39. Pioneering low-cost 3D-printed transtibial prosthetics to serve a rural population in Sierra Leone—An observational cohort study
40. Vitali, A., Regazzoni, D., Rizzi, C., and Colombo, G. (2017, January 3–9). Design and Additive Manufacturing of Lower Limb Prosthetic Socket. Proceedings of the ASME International Mechanical Engineering Congress and Exposition, Tampa, FL, USA.10.1115/IMECE2017-71494 ↗
41. Principal structural testing of trans–tibial prosthetic assemblies: Specimen preparation10.1080/03093640008726554 ↗
42. Static structural testing of trans-tibial composite sockets10.3109/03093649909071622 ↗