Evaluation of Deviations between Computer-Planned Implant Position and In Vivo Placement through 3D-Printed Guide: A CBCT Scan Analysis on Implant Inserted in Esthetic Area
Source abstract
Abstract
Background: Implant rehabilitation in cases of monoedentulism in the esthetic area is a challenge for the clinician. The aim of our study was to test the diagnostic–therapeutic accuracy of computer-guided implant placement in the esthetic area. Methods: Postimplant surgery cone beam computed tomography (CBCT) scans were retrospectively analyzed to assess the accuracy of computer-guided implant placement compared to the preoperative computer-digital planned implant position. We selectively enrolled CBCT scans of patients who underwent immediate or delayed implant placement of a single maxillary incisor, treated with computer-guided implant surgery through a tooth-supported digitally designed 3D printed guide. Our analysis consisted of three digital measurements: the mean deviation of the implant axis, and the mean mesiodistal implant deviation measured both at the apex and at the head of the implant. Results: A total of 95 implants were placed in 95 patients (60 Males, 35 Females; age from 27 to 45-year-old). Congruence analysis showed a mean deviation of implant axis of 1.04° ± 0.56° in sagittal projection, a mean mesiodistal implant deviation between adjacent teeth of 0.14 mm ± 0.07 mm at implant head level and 0.8 mm ± 0.3 mm at the apex in axial projection. Conclusions: computer-guided implant placement through a tooth-supported guide was extremely accurate in the esthetic area because the deviations between the real implant position and the preoperative planning was not clinically relevant.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Dental Radiography and Imaging · Periodontal Regeneration and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Medicine, Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84084 Salerno, Italy
References (32)
Show source-provided references
1. A 5-Year Longitudinal Cohort Study on Crown to Implant Ratio Effect on Marginal Bone Level in Single Implants10.1111/cid.12757 ↗
2. Computed Tomography-Aided Descriptive Analysis of Maxillary and Mandibular Atrophies10.1016/j.jormas.2018.12.006 ↗
3. Which Is the Best Choice after Tooth Extraction, Immediate Implant Placement or Delayed Placement with Alveolar Ridge Preservation? A Systematic Review and Meta-Analysis10.1016/j.jcms.2019.08.004 ↗
4. Timing of Implant Placement after Tooth Extraction: Immediate, Immediate-Delayed or Delayed Implants? A Cochrane Systematic Review
5. Variations in Soft and Hard Tissues Following Immediate Implant Placement versus Delayed Implant Placement Following Socket Preservation in the Maxillary Esthetic Region: A Randomized Controlled Clinical Trial10.1155/2021/5641185 ↗
6. Ridge Alterations Post-Extraction in the Esthetic Zone: A 3D Analysis with CBCT10.1177/0022034513506713 ↗
7. Soft Tissue Alterations in Esthetic Postextraction Sites: A 3-Dimensional Analysis10.1177/0022034515592869 ↗
8. The Influence of Bone Thickness on Facial Marginal Bone Response: Stage 1 Placement through Stage 2 Uncovering10.1902/annals.2000.5.1.119 ↗
9. Biomechanical Factors Affecting the Bone-Dental Implant Interface10.1016/0267-6605(92)90049-Y ↗
10. Influence of Forces on Peri-Implant Bone10.1111/j.1600-0501.2006.01360.x ↗
11. Di Stefano, D.A., Arosio, P., Capparè, P., Barbon, S., and Gherlone, E.F. (2021). Stability of Dental Implants and Thickness of Cortical Bone: Clinical Research and Future Perspectives. A Systematic Review. Materials, 14.10.3390/ma14237183 ↗
12. Consensus Statements and Recommended Clinical Procedures Regarding Optimizing Esthetic Outcomes in Implant Dentistry10.11607/jomi.2013.g3 ↗
13. Consensus Statements and Clinical Recommendations for Implant Loading Protocols10.11607/jomi.2013.g4 ↗
14. Computed Tomography Evaluation of Jaw a Trophies before and after Surgical Bone Augmentation
15. Factors Influencing Ridge Alterations Following Immediate Implant Placement into Extraction Sockets10.1111/j.1600-0501.2009.01825.x ↗
16. Dimensional Ridge Alterations Following Tooth Extraction. An Experimental Study in the Dog10.1111/j.1600-051X.2005.00642.x ↗
17. Different Techniques of Static/Dynamic Guided Implant Surgery: Modalities and Indications10.1111/prd.12056 ↗
18. Guided Implant Surgery Risks and Their Prevention10.1111/prd.12292 ↗
19. Interventions for replacing missing teeth: Dental implants in fresh extraction sockets (immediate, immediate-delayed and delayed implants)
20. Immediate versus delayed loading of post-extraction implants in the aesthetic zone: A prospective longitudinal study with 4-year follow-up
21. Immediate, immediate-delayed (6 weeks) and delayed (4 months) post-extractive single implants: 1-year post-loading data from a randomised controlled trial
22. Influence of Surgeon Experience on the Accuracy of Implant Placement via a Partially Computer-Guided Surgical Protocol10.11607/jomi.7480 ↗
23. The Accuracy of Single-Tooth Implants Placed Using Fully Digital-Guided Surgery and Freehand Implant Surgery10.1111/jcpe.13160 ↗
24. Is Digital Guided Implant Surgery Accurate and Reliable?10.1016/j.cden.2019.02.006 ↗
25. Effect of Flapless Surgery on Pain Experienced in Implant Placement Using an Image-Guided System
26. Kernen, F., Kramer, J., Wanner, L., Wismeijer, D., Nelson, K., and Flügge, T. (2020). A review of virtual planning software for guided implant surgery—Data import and visualization, drill guide design and manufacturing. BMC Oral. Health, 20.10.1186/s12903-020-01208-1 ↗
27. Lo Giudice, A., Quinzi, V., Ronsivalle, V., Martina, S., Bennici, O., and Isola, G. (2020). Description of a Digital Work-Flow for CBCT-Guided Construction of Micro-Implant Supported Maxillary Skeletal Expander. Materials, 13.10.3390/ma13081815 ↗
28. Schmidt, A., Wöstmann, B., and Schlenz, M.A. (2022). Accuracy of digital implant impressions in clinical studies: A systematic review. Clin. Oral. Implant. Res.10.1111/clr.13951 ↗
29. Two-dimensional versus three-dimensional Frӓnkel Manoeuvre: A reproducibility study10.1093/ejo/cjz081 ↗
30. Fabrication of Customized dental guide by stereolithography method and evaluation of dimensional accuracy with artificial neural networks10.1016/j.jmbbm.2021.105071 ↗
31. How Does an Error in Positioning the Template Affect the Accuracy of Implants Inserted Using a Single Fixed Mucosa-Supported Stereolithographic Surgical Guide?10.1016/j.ijom.2013.06.012 ↗
32. Clinical Application of Stereolithographic Surgical Guides for Implant Placement: Preliminary Results10.1902/jop.2005.76.4.503 ↗