Impact of Dental Model Height on Thermoformed PET-G Aligner Thickness—An In Vitro Micro-CT Study
Source abstract
Abstract
The aim of the present study was to investigate whether base height of 3D-printed dental models has an impact on local thickness values from polyethylene terephthalate glycol (PET-G) aligners. A total of 20 aligners were thermoformed on dental models from the upper jaw exhibiting either a 5 mm high (H) or narrow (N), i.e., 0 mm, base height. The aligners were digitized using micro-CT, segmented, and local thickness values were computed utilizing a 3D-distance transform. The mean thickness values and standard deviations were assessed for both groups, and local thickness values at pre-defined reference points were also recorded. The statistical analysis was performed using R. Aligners in group H were significantly thinner and more homogenous compared to group N (p < 0.001). Significant differences in thickness values were observed among tooth types between both groups. Whereas thickness values were comparable at cusp tips and occlusal/incisal/cervical measurement locations, facial and palatal surfaces were significantly thicker in group N compared to group H (p < 0.01). Within the limits of the study, the base height of 3D-printed models impacts on local thickness values of thermoformed aligners. The clinician should consider potential implication on exerted forces at the different tooth types, and at facial as well as palatal surfaces.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Dental Radiography and Imaging · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Orthodontics, University of Düsseldorf, 40225 Düsseldorf, Germany
Private Practice, 31224 Peine, Germany
Department of Oral Surgery, University of Düsseldorf, 40225 Düsseldorf, Germany
References (43)
Show source-provided references
1. (2021, March 03). Q4 and 2018 Corporate Fact Sheet. Available online: http://www.aligntech.com/documents/Align%20Technology%20Corp%20Fact%20Sheet%202018%20Q4.pdf.
2. Effect of in vitro aging by water immersion and thermocycling on the mechanical properties of PETG aligner material10.1007/s00056-019-00192-8 ↗
3. Incidence of white spot lesions among patients treated with clear aligners and traditional braces10.2319/073118-553.1 ↗
4. Periodontal health during clear aligners treatment: A systematic review10.1093/ejo/cju083 ↗
5. Effect of clear aligners on oral health-related quality of life: A systematic review10.1111/ocr.12382 ↗
6. Ke, Y., Zhu, Y., and Zhu, M. (2019). A comparison of treatment effectiveness between clear aligner and fixed appliance therapies. BMC Oral Health, 19.10.1186/s12903-018-0695-z ↗
7. Effectiveness of clear aligner therapy for orthodontic treatment: A systematic review10.1111/ocr.12353 ↗
8. Accuracy of clear aligners: A retrospective study of patients who needed refinement10.1016/j.ajodo.2017.11.028 ↗
9. Moving towards precision orthodontics: An evolving paradigm shift in the planning and delivery of customized orthodontic therapy10.1111/ocr.12171 ↗
10. Root resorption in orthodontic treatment with clear aligners: A systematic review and meta-analysis10.1111/ocr.12337 ↗
11. Orthodontic aligners and root resorption: A systematic review
12. Force magnitude and dura-tion effects on amount of tooth movement and root resorption in the rat molar10.2319/052007-240.1 ↗
13. Association of orthodontic force system and root resorption: A systematic review10.1016/j.ajodo.2014.12.026 ↗
14. Forces and moments delivered by PET-G aligners to an upper central incisor for labial and palatal translation10.1007/s00056-015-0307-3 ↗
15. Forces and moments delivered by novel, thinner PET-G aligners during labiopalatal bodily movement of a maxillary central incisor: An in vitro study10.2319/011316-37R.1 ↗
16. Initial Forces and Moments Delivered by Removable Thermoplastic Appliances during Rotation of an Upper Central Incisor10.2319/033009-181.1 ↗
17. Effects of mechanical properties of thermoplastic materials on the initial force of thermoplastic appliances10.2319/052512-432.1 ↗
18. Influence of thermoplastic appliance thickness on the magnitude of force delivered to a maxillary central incisor during tipping10.1016/j.ajodo.2008.12.015 ↗
19. Forces and moments delivered by the PET-G aligner to a maxillary central incisor for palatal tipping and intrusion10.2319/090216-666.1 ↗
20. Mechanical and geometric properties of thermoformed and 3D printed clear dental aligners10.1016/j.ajodo.2019.05.012 ↗
21. A microtomographic system for the nondestructive evaluation of bone architecture10.1007/BF02509542 ↗
22. Micro computed tomography evaluation of Invisalign aligner thickness homogeneity10.2319/040820-265.1 ↗
23. Lombardo, L., Palone, M., Longo, M., Arveda, N., Nacucchi, M., De Pascalis, F., Spedicato, G.A., and Siciliani, G. (2020). MicroCT X-ray comparison of aligner gap and thickness of six brands of aligners: An in-vitro study. Prog. Orthod., 21.10.1186/s40510-020-00312-w ↗
24. Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures in-volving six commercial clear aligners: An in vitro study10.4041/kjod.2021.51.2.135 ↗
25. A new method for the model-independent assessment of thickness in three-dimensional images10.1046/j.1365-2818.1997.1340694.x ↗
26. R Core Team (2021). R: A Language and Environment for Statistical Computing, R Foundation for Statistical Computing.
27. Fitting linear mixed-effects models using lme410.18637/jss.v067.i01 ↗
28. Lenth, R.V., Buerkner, P., Herve, M., Love, J., Riebl, H., and Singmann, H. (2021, May 10). Estimated Marginal Means, aka Least-Squares Means. Available online: https://cran.r-project.org/web/packages/emmeans/emmeans.pdf.
29. Simon, M., Keilig, L., Schwarze, J., Jung, B.A., and Bourauel, C. (2014). Treatment outcome and efficacy of an aligner technique—Regarding incisor torque, premolar derotation and molar distalization. BMC Oral Health, 14.10.1186/1472-6831-14-68 ↗
30. Richard, H.A., and Sander, M. (2008). Technische Mechanik. Festigkeitslehre: Lehrbuch mit Praxisbeispielen, Klausuraufgaben und Lösungen, Vieweg+Teubner.
31. Clear aligners for maxillary anterior en masse retraction: A 3D finite element study
32. Rossini, G., Schiaffino, M., Parrini, S., Sedran, A., Deregibus, A., and Castroflorio, T. (2020). Upper Second Molar Distalization with Clear Aligners: A Finite Element Study. Appl. Sci., 10.10.3390/app10217739 ↗
33. Initial force systems during bodily tooth movement with plastic aligners and composite attachments: A three-dimensional finite element analysis10.2319/050714-330.1 ↗
34. Effects of variable attachment shapes and aligner material on aligner retention10.2319/091014-637.1 ↗
35. Burstone, C.J., and Choy, K. (2015). The Biomechanical Foundation of Clinical Orthodontics, Quintessence Publishing Company, Inc.
36. Behaviour of monolayer and multilayer foils in the aligner thermoforming process
37. Sandhya, V., Arun, A., Reddy, V.P., Mahendra, S., and Chandrashekar, B. (2021). Biomechanical Effects of Torquing on Upper Central Incisor with Thermoplastic Aligner: A Comparative Three-Dimensional Finite Element Study with and Without Auxillaries. J. Indian Orthod. Soc., 1–8.10.1177/0301574220974340 ↗
38. Ethnic differences in the root to crown ratios of the permanent dentition10.1111/ocr.12288 ↗
39. Papadimitriou, A., Mousoulea, S., Gkantidis, N., and Kloukos, D. (2018). Clinical effectiveness of Invisalign® orthodontic treatment: A systematic review. Prog. Orthod., 19.10.1186/s40510-018-0235-z ↗
40. Effect of clear aligner therapy on the buccolingual inclination of mandibular canines and the intercanine distance10.2319/012615-59.1 ↗
41. Outcome assessment of Invisalign and traditional orthodontic treatment compared with the American Board of Orthodontics objective grading system10.1016/j.ajodo.2005.06.002 ↗
42. Li, J., and Wang, X. (2013, January 16–18). A fast 3D euclidean distance transformation. Proceedings of the 2013 6th International Congress on Image and Signal Processing (CISP), Hangzhou, China.10.1109/CISP.2013.6745288 ↗
43. Koenig, N.L. (2020). Accuracy of Fit of Direct Printed Aligners versus Thermoformed Aligners. [Master’s Thesis, Saint Louis University].