journal article·2019-05-01Open access

Box-Jenkins Transfer Function Modelling for Reliable Determination of VO2 Kinetics in Patients with COPD

Joren Buekers, Jan Theunis, Alberto Peña Fernández, Emiel F. M. Wouters, Martijn A. Spruit, Patrick De Boever, Jean-Marie Aerts

Applied Sciences· Volume 9· Issue 9

Abstract

Oxygen uptake (VO2) kinetics provide information about the ability to respond to the increased physical load during a constant work rate test (CWRT). Box-Jenkins transfer function (BJ-TF) models can extract kinetic features from the phase II VO2 response during a CWRT, without being affected by unwanted noise contributions (e.g., phase I contribution or measurement noise). CWRT data of 18 COPD patients were used to compare model fits and kinetic feature values between BJ-TF models and three typically applied exponential modelling methods. Autocorrelation tests and normalised root-mean-squared error values (BJ-TF: 2.8 ± 1.3%; exponential methods A, B and C: 10.5 ± 5.8%, 11.3 ± 5.2% and 12.1 ± 7.0%; p < 0.05) showed that BJ-TF models, in contrast to exponential models, could account for the most important noise contributions. This led to more reliable kinetic feature values compared to methods A and B (e.g., mean response time (MRT), BJ-TF: 74 ± 20 s; methods A-B: 100 ± 56 s–88 ± 52 s; p < 0.05). Only exponential modelling method C provided kinetic feature values comparable to BJ-TF features values (e.g., MRT: 75 ± 20 s). Based on theoretical considerations, we recommend using BJ-TF models, rather than exponential models, for reliable determinations of VO2 kinetics.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Cardiovascular and exercise physiology · Chronic Obstructive Pulmonary Disease (COPD) Research · Hemodynamic Monitoring and Therapy

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Health unit, Flemish Institute for Technological Research (VITO), 2400 Mol, Belgium

Measure, Model & Manage Bioresponses (M3-BIORES), Department of Biosystems, KU Leuven, 3000 Leuven, Belgium

Department of Research and Education, Centre of Expertise for Chronic Organ Failure (CIRO), 6085 NM Horn, The Netherlands

Department of Respiratory Medicine, Maastricht University Medical Centre, 6229 HX Maastricht, The Netherlands

REVAL—Rehabilitation Research Center, BIOMED—Biomedical Research Institute, Faculty of Rehabilitation Sciences, Hasselt University, 3500 Diepenbeek, Belgium

NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University Medical Centre, 6211 LK Maastricht, The Netherlands

Centre for Environmental Sciences, Hasselt University, 3500 Diepenbeek, Belgium

References (33)

Show source-provided references
1. Global Initiative for Chronic Obstructive Lung Disease (GOLD) (2019, January 30). Global strategy for the diagnosis, management, and prevention of Chronic Obstructive Pulmonary Disease—2019 Report 2019. Available online: https://goldcopd.org/wp-content/uploads/2018/11/GOLD-2019-v1.7-FINAL-14Nov2018-WMS.pdf.
2. An official European respiratory society statement on physical activity in COPD10.1183/09031936.00046814 ↗
3. American Thoracic Society (ATS), and American College of Chest Physicians (ACCP) (2003). ATS/ACCP Statement on cardiopulmonary exercise testing. Am. J. Respir. Crit. Care Med., 167, 211–277.10.1164/rccm.167.2.211 ↗
4. Towards an understanding of the mechanistic bases of VO2 kinetics10.1002/cphy.c100072 ↗
5. Ventilatory and gas exchange kinetics during exercise in chronic airways obstruction10.1152/jappl.1982.53.6.1594 ↗
6. Effect of hyperoxia on gas exchange and lactate kinetics following exercise onset in nonhypoxemic COPD patients10.1378/chest.121.2.393 ↗
7. Oxygen effect on O2 deficit and VO2 kinetics during exercise in obstructive pulmonary disease10.1152/jappl.1995.78.6.2228 ↗
8. Bronchodilator effect on ventilatory, pulmonary gas exchange, and heart rate kinetics during high-intensity exercise in COPD10.1007/s00421-009-1169-4 ↗
9. Bronchodilators accelerate the dynamics of muscle O2 delivery and utilisation during exercise in COPD10.1136/thx.2009.120857 ↗
10. Effects of two types of training on pulmonary and cardiac responses to moderate exercise in patients with COPD10.1034/j.1399-3003.2000.01509.x ↗
11. Effective bronchoscopic lung volume reduction accelerates exercise oxygen uptake kinetics in emphysema10.1378/chest.15-0404 ↗
12. Kinetics of muscle deoxygenation are accelerated at the onset of heavy-intensity exercise in patients with COPD: Relationship to central cardiovascular dynamics10.1152/japplphysiol.01364.2007 ↗
13. Quigley, S., and Van Horn, L. (2008). Time Series Analysis, John Wiley & Sons, Inc.. [4th ed.].
14. Integration of pulmonary rehabilitation in COPD10.1016/S0140-6736(08)60048-3 ↗
15. Pedregal, D.J., Taylor, C.J., and Young, P.C. (2007). System Identification, Time Series Analysis and Forecasting: The Captain Toolbox handbook, Lancaster University.
16. Young, P.C. (2011). Recursive Estimation and Time-Series Analysis: An. Introduction for the Student and Practitioner, Springer. [2nd ed.].10.1007/978-3-642-21981-8 ↗
17. Environmental time series analysis and forecasting with the Captain toolbox10.1016/j.envsoft.2006.03.002 ↗
18. Normal Standards for an Incremental Progressive Cycle Ergometer Test
19. Parameters of ventilatory dynamics during exercise
20. A comparison of modelling techniques used to characterise oxygen uptake kinetics during the on-transient of exercise10.1113/eph8602150 ↗
21. Are the parameters of VO2, heart rate and muscle deoxygenation kinetics affected by serial moderate-intensity exercise transitions in a single day?10.1007/s00421-010-1653-x ↗
22. Effect of interbreath fluctuations on characterizing exercise gas exchange kinetics10.1152/jappl.1987.62.5.2003 ↗
23. Breath-by-breath fluctuations of pulmonary gas exchange and ventilation in COPD patients10.1007/s00421-002-0649-6 ↗
24. On issues of confidence in determining the time constant for oxygen uptake kinetics10.1136/bjsm.2003.004721 ↗
25. Söderström, T. (2018). Errors-in-Variables Methods in System Identification, Springer International Publishing.10.1007/978-3-319-75001-9 ↗
26. Influence of phase I duration on phase II VO2 kinetics parameter estimates in older and young adults10.1152/ajpregu.00060.2011 ↗
27. Characterisation, asymmetry and reproducibility of on-and off-transient pulmonary oxygen uptake kinetics in endurance-trained runners10.1007/s00421-004-1232-0 ↗
28. Reliability of peak O2 uptake and O2 uptake kinetics in step exercise tests in healthy subjects10.1016/j.resp.2014.12.001 ↗
29. Reproducibility of the parameters of the on-transient cardiopulmonary responses during moderate exercise in patients with chronic obstructive pulmonary disease10.1007/s004210100486 ↗
30. A comparison of two time-domain analysis procedures in the determination of VO2 kinetics by pseudorandom binary sequence exercise testing10.1007/s00421-002-0725-y ↗
31. Open-circuit respirometry: A historical review of portable gas analysis systems10.1007/s00421-017-3716-8 ↗
32. Van Remoortel, H., Raste, Y., Louvaris, Z., Giavedoni, S., Burtin, C., Langer, D., Wilson, F., Rabinovich, R., Vogiatzis, I., and Hopkinson, N.S. (2012). Validity of Six Activity Monitors in Chronic Obstructive Pulmonary Disease: A Comparison with Indirect Calorimetry. PLoS ONE, 7.10.1371/journal.pone.0039198 ↗
33. Time-variant modelling of heart rate responses to exercise intensity during road cycling10.1080/17461391.2012.708791 ↗