journal article·2023-01-29Open access

Inter-Session Repeatability of Marker-Less Motion Capture of Treadmill Running Gait

Matthew F. Moran, Isabella C. Rogler, Justin C. Wager

Applied Sciences· Volume 13· Issue 3

Abstract

Twenty-one experienced runners completed three treadmill running sessions on different days. Each session consisted of three consecutive 2 min trials at self-selected speeds (RPE = 3, 5, and 7). An eight-camera marker-less motion capture system and instrumented pressure treadmill (TM) collected data over the final ~25 s at each speed. Lower extremity joint angles (ankle, knee, and hip) and segmental angles (pelvis and trunk) were computed for each trial with foot contact and toe off being kinematically determined. Spatiotemporal metrics (ground contact time, step length, and cadence) were measured via TM and compared to their kinematically derived counterparts. All spatiotemporal metrics demonstrated excellent agreement (ICCs > 0.98). Both intra-trial and inter-session variability, averaged across the entire running cycle, for all lower extremity joint angles in all planes were low (intra-trial: sagittal = 2.0°, frontal = 1.2°, and transverse = 1.9°; inter-session: sagittal = 1.4°, frontal = 0.8°, and transverse = 1.3°). Discrete measures of lower extremity joint and segmental angles were evaluated for inter-session reliability at foot contact, toe off, and peak value during the stance phase. On average, discrete measures demonstrated good reliability (ICCsagittal = 0.85, ICCfrontal = 0.83, and ICCtransverse = 0.77) with average standard error of measurement < 1°. Marker-less motion capture reliably measured treadmill running kinematics in a group of runners demonstrating heterogenous foot strike patterns (13 rearfoot strike and 8 non-rearfoot strike) across a range of speeds (2.67–4.44 m/s).
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Lower Extremity Biomechanics and Pathologies · Diabetic Foot Ulcer Assessment and Management · Foot and Ankle Surgery

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Physical Therapy and Human Movement Science, Sacred Heart University, Fairfield, CT 06825, USA

References (28)

Show source-provided references
1. A Review of the Evolution of Vision-Based Motion Analysis and the Integration of Advanced Computer Vision Methods Towards Developing a Markerless System10.1186/s40798-018-0139-y ↗
2. Skin Movement Artefact Assessment and Compensation in the Estimation of Knee-Joint Kinematics10.1016/S0021-9290(98)00083-9 ↗
3. Human Movement Analysis Using Stereophotogrammetry: Part 3. Soft Tissue Artifact Assessment and Compensation10.1016/j.gaitpost.2004.05.002 ↗
4. Assessment of the Kinematic Variability among 12 Motion Analysis Laboratories10.1016/j.gaitpost.2008.10.060 ↗
5. Repeatability of Kinematic, Kinetic, and Electromyographic Data in Normal Adult Gait10.1002/jor.1100070611 ↗
6. Osis, S.T., Hettinga, B.A., Macdonald, S., and Ferber, R. (2016). Effects of Simulated Marker Placement Deviations on Running Kinematics and Evaluation of a Morphometric-Based Placement Feedback Method. PLoS ONE, 11.10.1371/journal.pone.0147111 ↗
7. Applications and Limitations of Current Markerless Motion Capture Methods for Clinical Gait Biomechanics10.7717/peerj.12995 ↗
8. Absolute Reliability of Gait Parameters Acquired With Markerless Motion Capture in Living Domains10.3389/fnhum.2022.867474 ↗
9. Accuracy of a Markerless Motion Capture System in Estimating Upper Extremity Kinematics during Boxing10.3389/fspor.2022.939980 ↗
10. Concurrent Assessment of Gait Kinematics Using Marker-Based and Markerless Motion Capture10.1016/j.jbiomech.2021.110665 ↗
11. Markerless versus Marker-Based Motion Analysis in Subjects with Lower Limb Amputation: A Case Series10.1016/j.gaitpost.2022.07.067 ↗
12. Assessment of Spatiotemporal Gait Parameters Using a Deep Learning Algorithm-Based Markerless Motion Capture System10.1016/j.jbiomech.2021.110414 ↗
13. Inter-Session Repeatability of Markerless Motion Capture Gait Kinematics10.1016/j.jbiomech.2021.110422 ↗
14. Fleisig, G.S., Slowik, J.S., Wassom, D., Yanagita, Y., Bishop, J., and Diffendaffer, A. (2022). Comparison of Marker-Less and Marker-Based Motion Capture for Baseball Pitching Kinematics. Sport. Biomech., 1–10.10.1080/14763141.2022.2076608 ↗
15. Comparison of Methods for Kinematic Identification of Footstrike and Toe-off during Overground and Treadmill Running10.1016/j.jsams.2010.03.006 ↗
16. A Kinematic Method to Detect Foot Contact during Running for All Foot Strike Patterns10.1016/j.jbiomech.2015.07.036 ↗
17. Clothing Condition Does Not Affect Meaningful Clinical Interpretation in Markerless Motion Capture10.1016/j.jbiomech.2022.111182 ↗
18. A Fortran Package for Generalized, Cross-Validatory Spline Smoothing and Differentiation
19. Dempster, W.T., and Wilfrid, T. (1955). Space Requirements of the Seated Operator: Geometrical, Kinematic, and Mechanical Aspects of the Body, with Special Reference to the Limbs, Wright Air Development Center.10.21236/AD0087892 ↗
20. Hanavan, E. (1964). A Mathematical Model of the Human Body (Technical Report AMRL-TDR-64–102) Wright-Patterson Air Force Base. OJ Wright Air Dev. Cent., 1–149.
21. Anatomical Data for Analyzing Human Motion10.1080/02701367.1983.10605290 ↗
22. A Joint Coordinate System for the Clinical Description of Three-Dimensional Motions: Application to the Knee10.1115/1.3138397 ↗
23. The Reliability of Kinetic and Kinematic Variables Used to Analyse Normal Running Gait10.1016/S0966-6362(01)00125-4 ↗
24. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research10.1016/j.jcm.2016.02.012 ↗
25. Measurement and Management of Errors in Quantitative Gait Data10.1016/j.gaitpost.2003.09.011 ↗
26. Variability of Segment Coordination Using a Vector Coding Technique: Reliability Analysis for Treadmill Walking and Running10.1016/j.gaitpost.2016.11.004 ↗
27. The Reliability of Three-Dimensional Kinematic Gait Measurements: A Systematic Review10.1016/j.gaitpost.2008.09.003 ↗
28. The between-Day Repeatability, Standard Error of Measurement and Minimal Detectable Change for Discrete Kinematic Parameters during Treadmill Running10.1016/j.gaitpost.2020.12.032 ↗