Abstract

As digital workflows are gaining popularity, novel treatment options have also arisen in orthodontics. By using selective laser melting (SLM), highly customized 3D-printed appliances can be manufactured and combined with preformed components. When combined with temporary anchorage devices (TADs), the advantages of the two approaches can be merged, which might improve treatment efficacy, versatility, and patient comfort. This article summarizes state-of-the-art technologies and digital workflows to design and install 3D-printed skeletally anchored orthodontic appliances. The advantages and disadvantages of digital workflows are critically discussed, and examples for the clinical application of mini-implant and mini-plate borne appliances are demonstrated.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Additive Manufacturing and 3D Printing Technologies · Orthodontics and Dentofacial Orthopedics · Anatomy and Medical Technology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Orthodontics, University Clinic Düsseldorf, Moorenstrasse 5, 40225 Düsseldorf, Germany

References (65)

Show source-provided references
1. 3D-printed patient-specific applications in orthopedics
2. 3D-printing techniques in a medical setting: A systematic literature review10.1186/s12938-016-0236-4 ↗
3. Three-Dimensional Printing in Plastic and Reconstructive Surgery: A Systematic Review10.1097/SAP.0000000000000671 ↗
4. 3D Printing in Pharmaceutical and Medical Applications—Recent Achievements and Challenges10.1007/s11095-018-2454-x ↗
5. 3D printing restorative materials using a stereolithographic technique: A systematic review10.1016/j.dental.2020.11.030 ↗
6. A Review of 3D Printing in Dentistry: Technologies, Affecting Factors, and Applications10.1155/2021/9950131 ↗
7. Computer-aided design and manufacture of hyrax devices: Can we really go digital?10.1016/j.ajodo.2017.06.016 ↗
8. CAD-CAM design and 3-dimensional printing of mini-implant retained orthodontic appliances10.1016/j.ajodo.2018.07.013 ↗
9. Class III Treatment with Skeletal and Dental Anchorage: A Review of Comparative Effects10.1155/2018/7946019 ↗
10. Comparison of skeletal and conventional anchorage methods in conjunction with pre-operative decompensation of a skeletal class III malocclusion10.1007/s00056-009-9909-y ↗
11. Proffit, W.R., and Fields, H.W. (1993). Contemporary Orthodontics, Mosby-Year Book.
12. Extrusion of impacted teeth using mini-implant mechanics
13. Systematic review of mini-implant displacement under orthodontic loading10.1038/ijos.2013.92 ↗
14. Mini-Implantate zur kieferorthopädischen Verankerung im anterioren Gaumen, mediane vs. paramediane Insertion10.1055/s-0035-1565165 ↗
15. The T-Zone: Median vs. Paramedian Insertion of Palatal Mini-Implants
16. Efficacy of orthodontic mini implants for en masse retraction in the maxilla: A systematic review and meta-analysis10.1186/s40729-018-0144-4 ↗
17. Skeletally anchored mesialization of molars using digitized casts and two surface-matching approaches: Analysis of treatment effects10.1007/s00056-017-0108-y ↗
18. Clinical suitability of titanium microscrews for orthodontic anchorage-preliminary experiences10.1007/s00056-004-0408-x ↗
19. A miniscrew system with interchangeable abutments
20. Anatomical guidelines for miniscrew insertion: Palatal sites
21. Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: A systematic review and meta-analysis10.1186/s40510-018-0225-1 ↗
22. Preprosthetic molar uprighting using skeletal anchorage
23. Anatomical guidelines for miniscrew insertion: Vestibular interradicular sites
24. “Safe zones”: A guide for miniscrew positioning in the maxillary and mandibular arch
25. Root contact during insertion of miniscrews for orthodontic anchorage increases the failure rate: An animal study10.1111/j.1600-0501.2007.01418.x ↗
26. Contact damage to root surfaces of premolars touching miniscrews during orthodontic treatment10.1016/j.ajodo.2006.09.069 ↗
27. Survival estimates and risk factors for failure of palatal and buccal mini-implants10.2319/090720-777.1 ↗
28. Early Class III treatment with a hybrid hyrax-mentoplate combination
29. The efficacy of Hybrid Hyrax-Mentoplate combination in early Class III treatment: A novel approach and pilot study
30. Bicortical titanium screws for critical orthodontic anchorage in the mandible: A preliminary report on clinical applications10.1034/j.1600-0501.2001.012004358.x ↗
31. Multifunctional use of palatal mini-implants
32. Becker, K., de Gabriele, R., Dallatana, G., Trelenberg-Stoll, V., Wilmes, B., and Drescher, D. (2018). 3-D-Planung für Implantate in der Kieferorthopädie, Quintessence Publishing.
33. Hybrid Hyrax Direct
34. Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation10.1111/j.1600-0501.1997.tb00001.x ↗
35. Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys10.1034/j.1600-0501.1996.070208.x ↗
36. Jedliński, M., Mazur, M., Grocholewicz, K., and Janiszewska-Olszowska, J. (2021). 3D Scanners in Orthodontics-Current Knowledge and Future Perspectives—A Systematic Review. Int. J. Environ. Res. Public Health, 18.10.3390/ijerph18031121 ↗
37. Validity and reliability of intraoral scanners compared to conventional gypsum models measurements: A systematic review10.1093/ejo/cjw033 ↗
38. A comparison of patient experience, chair-side time, accuracy of dental arch measurements and costs of acquisition of dental models10.2319/020619-84.1 ↗
39. Three-dimensional printing technology
40. Klinische Anwendung des digitalen Workflows am Beispiel von Mini-Implantaten10.1055/a-1162-3794 ↗
41. Suitability of virtual plaster models superimposed with the lateral cephalogram for guided paramedian orthodontic mini-implant placement with regard to the bone support10.1007/s00056-020-00238-2 ↗
42. Accuracy of fully guided orthodontic mini-implant placement evaluated by cone-beam computed tomography: A study involving human cadaver heads10.1007/s00784-020-03436-9 ↗
43. The easy driver for placement of palatal mini-implants and a maxillary expander in a single appointment
44. Rapid protyping technology in medicine-basics and applications10.1016/S0895-6111(99)00025-7 ↗
45. Accuracy of orthodontic mini-implants placed at the anterior palate by tooth-borne or gingiva-borne guide support: A cadaveric study10.1007/s00784-019-02885-1 ↗
46. Vertical palatal bone dimensions on lateral cephalometry and cone-beam computed tomography: Implications for palatal implant placement10.1111/j.1600-0501.2010.02021.x ↗
47. Three-dimensional metal printed orthodontic laboratory appliances10.1053/j.sodo.2021.09.005 ↗
48. Selective laser sintering in biomedical engineering10.1007/s11517-012-1001-x ↗
49. Application of optical digitizing techniques to evaluate the shape accuracy of anatomical models derived from computed tomography data10.1016/j.joms.2005.11.083 ↗
50. Gokuldoss, P.K., Kolla, S., and Eckert, J. (2017). Additive Manufacturing Processes: Selective Laser Melting, Electron Beam Melting and Binder Jetting-Selection Guidelines. Materials, 10.10.3390/ma10060672 ↗
51. Effect of finish line design and metal alloy on the marginal and internal gaps of selective laser melting printed copings10.1016/j.prosdent.2019.02.009 ↗
52. Dimensional precision of implant-supported frameworks fabricated by 3D printing10.1016/j.prosdent.2019.01.019 ↗
53. Effect of manufacturing techniques on the marginal and internal fit of cobalt-chromium implant-supported multiunit frameworks10.1016/j.prosdent.2018.02.012 ↗
54. Bae, S., Hong, M.H., Lee, H., Lee, C.H., Hong, M., Lee, J., and Lee, D.H. (2020). Reliability of Metal 3D Printing with Respect to the Marginal Fit of Fixed Dental Prostheses: A Systematic Review and Meta-Analysis. Materials, 13.10.3390/ma13214781 ↗
55. 3D printing and digital processing techniques in dentistry: A review of literature10.1002/adem.201801013 ↗
56. Sterilization of implantable polymer-based medical devices: A review10.1016/j.ijpharm.2017.12.003 ↗
57. Sterilization of bedside 3D-printed devices for use in the operating room10.1016/j.stlm.2022.100045 ↗
58. Effects of different sterilization methods on the physico-chemical and bioresponsive properties of plasma-treated polycaprolactone films10.1088/1748-605X/aa51d5 ↗
59. Sharma, N., Cao, S., Msallem, B., Kunz, C., Brantner, P., Honigmann, P., and Thieringer, F.M. (2020). Effects of Steam Sterilization on 3D Printed Biocompatible Resin Materials for Surgical Guides-An Accuracy Assessment Study. J. Clin. Med., 9.10.3390/jcm9051506 ↗
60. Does vaporized hydrogen peroxide sterilization affect the geometrical properties of anatomic models and guides 3D printed from computed tomography images?10.1186/s41205-021-00120-w ↗
61. Pérez Davila, S., González Rodríguez, L., Chiussi, S., Serra, J., and González, P. (2021). How to Sterilize Polylactic Acid Based Medical Devices?. Polymers, 13.10.3390/polym13132115 ↗
62. Immediate loading of implants used for orthodontic anchorage10.1034/j.1600-0544.2000.030105.x ↗
63. Application of Orthodontic Immediate Force on Dental Implants: Histomorphologic and Histomorphometric Assessment10.4103/ams.ams_35_15 ↗
64. Diagnostic accuracy and measurement sensitivity of digital models for orthodontic purposes: A systematic review10.1016/j.ajodo.2015.06.029 ↗
65. Shannon, T., and Groth, C. (2021). Be your own manufacturer: 3D printing intraoral appliances. Seminars in Orthodontics Seminars, WB Saunders.10.1053/j.sodo.2021.09.004 ↗