journal article·2021-01-11Open access

Comparative Analysis of the Stability of Prosthetic Screws under Cyclic Loading in Implant Prosthodontics: An In Vitro Study

Santo Catapano, Mattia Ferrari, Nicola Mobilio, Marco Montanari, Massimo Corsalini, Francesco Grande

Applied Sciences· Volume 11· Issue 2

Abstract

Background: To compare the loss of preload in absence of loading and after a fixed number of cyclic loadings on 7-mm distal cantilever in two different connection systems using all-on-four prosthetic model. Methods: Two equal models of an edentulous mandible rehabilitated with all-on-four technique with two types of abutment system (MUA and OT-Bridge) supporting a hybrid prosthesis, were used. Initial torque values of the prosthetic fixing screw, after ten minutes from initial screw tightening and after 400,000 repeated loadings were registered using a mechanical torque gauge. Differences between initial and final torque values were reported for each anchoring system and the two systems were finally compared. Results: No statistically significant differences regarding the loss of preload between MUA and OT-Bridge system were found after 400,000 cyclic loadings; however, in MUA system it was found between anterior and posterior implant screws. A significant difference in preload loss was found only for MUA system comparing the initial screw torque to that measured after 10 min from the tightening in absence of cyclic loadings. Conclusions: Within the limits of the present study, MUA and OT-Bridge may be considered reliable prosthetic anchoring systems able to tolerate repeated cyclic occlusal loads on distal cantilever in all-on-four rehabilitation model without any significant loss of preload in screw tightening.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental Radiography and Imaging · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Prosthodontics, University of Ferrara, Via Luigi Borsari, 46-44121 Ferrara, Italy

Interdisciplinary Department of Medicine, University of Bari, Piazza Giulio Cesare, 11-70124 Bari, Italy

References (38)

Show source-provided references
1. The use of monolithic lithium disilicate for posterior screw-retained implant crowns10.1016/j.prosdent.2016.12.023 ↗
2. Survival rates of lithium disilicate single restorations: A retrospective study10.11607/ijp.5601 ↗
3. Pessin Camatta, H., Melim Ferreira, R., Mota Ferrairo, B., Sandy Strelhow, S., Henrique Rubo, J., Akemi Mori, A., and Feruzzi, F. (2020). Mechanical behavior and fracture loads of screw-retained and cement-retained lithium disilicate implant-supported crowns. J. Prosthodont., 27.10.1111/jopr.13298 ↗
4. Fixed implant rehabilitation for the edentulous maxilla
5. A classification of the edentulous jaws10.1016/S0901-5027(88)80047-X ↗
6. Clinical reliability of CAD/CAM cross-arch zirconia bridges on immediately loaded implants placed with computer-assisted/template-guided surgery: A retrospective study with a follow-up between 3 and 5 years: Clinical reliability of CAD/CAM cross-arch zirconia bridges
7. Pellegrino, G., Grande, F., Ferri, A., Pisi, P., Gandolfi, M.G., and Marchetti, C. (2020). Three-dimensional radiographic evaluation of the malar bone engagement available for ideal zygomatic implant placement. Methods Protoc., 3.10.3390/mps3030052 ↗
8. ‘All-on-4’ immediate-function concept for completely edentulous maxillae: A clinical report on the medium (3 years) and long-term (5 years) outcomes
9. A retrospective analysis of 800 Brånemark system implants following the all-on-fourTM protocol: All-on-Four retrospective analysis10.1111/jopr.12089 ↗
10. Five-year results of a randomized controlled trial comparing patients rehabilitated with immediately loaded maxillary cross-arch fixed dental prosthesis supported by four or six implants placed using guided surgery: Fixed prosthesis on four versus six implants: A 5-Year RCT10.1111/cid.12380 ↗
11. A prospective study on implants installed with flapless-guided surgery using the all-on-four concept in the mandible10.1111/j.1600-0501.2011.02344.x ↗
12. Impact of fixed implant supported prostheses in edentulous patients: Protocol for a systematic review
13. Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review
14. Tallarico, M., Ortensi, L., Martinolli, M., Casucci, A., Ferrari, E., Malaguti, G., Montanari, M., Scrascia, R., Vaccaro, G., and Venezia, P. (2018). Multicenter retrospective analysis of implant overdentures delivered with different design and attachment systems: Results between one and 17 years of follow-up. Dent. J., 6.10.3390/dj6040071 ↗
15. Clinical complications with implants and implant prostheses10.1016/S0022-3913(03)00212-9 ↗
16. A systematic review of the survival and complication rates of implant supported fixed dental prostheses with cantilever extensions after an observation period of at least 5 years10.1111/j.1600-0501.2009.01706.x ↗
17. Systematic analysis of factors that cause loss of preload in dental implants10.4103/jips.jips_294_17 ↗
18. Implant screw mechanics and the settling effect: Overview10.1563/1548-1336(2003)029<0242:ISMATS>2.3.CO;2 ↗
19. Implant abutment screw rotations and preloads for four different screw materials and surfaces10.1067/mpr.2001.116230 ↗
20. Mechanical comparison of experimental conical-head abutment screws with conventional flat-head abutment screws for external-hex and internal tri-channel implant connections: An in vitro evaluation of loosening torque10.11607/jomi.3029 ↗
21. Cantilever and implant biomechanics: A review of the literature, part 110.1111/j.1532-849X.1994.tb00124.x ↗
22. Implant-supported cantilevered fixed dental rehabilitations in fully edentulous patients: Systematic review of the literature. Part II10.1111/clr.13310 ↗
23. Bite force and dental implant treatment: A short review
24. Increasing the number of masticatory cycles is associated with reduced appetite and altered postprandial plasma concentrations of gut hormones, insulin and glucose10.1017/S0007114512005053 ↗
25. The effect of eliminating implant/abutment rotational misfit on screw joint stability
26. Stress fatigue: Basic principles and prosthodontic implications
27. Complications in implant dentistry10.4103/ejd.ejd_340_16 ↗
28. Relationship between implant preload and screw loosening on implant-supported prostheses10.1563/1548-1336(2002)028<0067:TRBIPA>2.3.CO;2 ↗
29. Pellegrino, G., Basile, F., Relics, D., Ferri, A., Grande, F., Tarsitano, A., and Marchetti, C. (2020). Computer-aided rehabilitation supported by zygomatic implants: A cohort study comparing atrophic with oncologic patients after five years of follow-up. J. Clin. Med., 12.10.3390/jcm9103254 ↗
30. An up to 7-year retrospective analysis of biologic and technical complication with the all-on-4 concept10.1563/aaid-joi-D-15-00098 ↗
31. Two years after loading performance of implant-supported overdenture with metal bar and low-profile attachments: A prospective case series multicenter clinical study10.1155/2020/8830722 ↗
32. Effects of abutment screw coating on implant preload10.1111/j.1532-849X.2010.00595.x ↗
33. Influence of cyclic fatigue in water on screw torque loss of long-span one-piece implant-supported zirconia frameworks10.1111/jopr.12398 ↗
34. Influence of abutment type and esthetic veneering on preload maintenance of abutment screw of implant-supported crowns10.1111/jopr.12065 ↗
35. Effect of casting procedures on screw loosening in UCLA-type abutments10.1111/j.1532-849X.2006.00078.x ↗
36. Elongation and preload stress in dental implant abutment screws
37. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies10.1111/j.1532-849X.2006.00096.x ↗
38. Ortensi, L., Martinolli, M., Borromeo, C., Ceruso, F.M., Gargari, M., Xhanari, E., and Tallarico, M. (2019). Effectiveness of ball attachment systems in implant retained- and supported-overdentures: A three- to five-year retrospective examination. Dent. J., 1.10.3390/dj7030084 ↗