journal article·2020-03-21Open access

Photoplethysmographic Prediction of the Ankle-Brachial Pressure Index through a Machine Learning Approach

David Perpetuini, Antonio Maria Chiarelli, Daniela Cardone, Sergio Rinella, Simona Massimino, Francesco Bianco, Valentina Bucciarelli, Vincenzo Vinciguerra, Giorgio Fallica, Vincenzo Perciavalle, Sabina Gallina, Arcangelo Merla

Applied Sciences· Volume 10· Issue 6

Abstract

Cardiovascular disease is a leading cause of death. Several markers have been proposed to predict cardiovascular morbidity. The ankle-brachial index (ABI) marker is defined as the ratio between the ankle and the arm systolic blood pressures, and it is generally assessed through sphygmomanometers. An alternative tool for cardiovascular status assessment is Photoplethysmography (PPG). PPG is a non-invasive optical technique that measures volumetric blood changes induced by pulse pressure propagation within arteries. However, PPG does not provide absolute pressure estimation, making assessment of cardiovascular status less direct. The capability of a multivariate data-driven approach to predict ABI from peculiar PPG features was investigated here. ABI was measured using a commercial instrument (Enverdis Vascular Explorer, VE-ABI), and it was then used for a General Linear Model estimation of ABI from multi-site PPG in a supervised learning framework (PPG-ABI). A Receiver Operating Characteristic (ROC) analysis allowed to investigate the capability of PPG-ABI to discriminate cardiovascular impairment as defined by VE-ABI. Findings suggested that ABI can be estimated form PPG (r = 0.79) and can identify pathological cardiovascular status (AUC = 0.85). The advantages of PPG are simplicity, speed and operator-independency, allowing extensive screening of cardiovascular status and associated cardiovascular risks.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Hemodynamic Monitoring and Therapy · Cardiovascular Health and Disease Prevention

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute for Advanced Biomedical Technologies, Department of Neuroscience and Imaging, University G. D’Annunzio of Chieti-Pescara, Via Luigi Polacchi 13, 66100 Chieti, Italy

Physiology Section, Department of Biomedical and Biotechnological Sciences, University of Catania, Via Santa Sofia 97, 95123 Catania, Italy

Institute of Cardiology, University G. D’Annunzio of Chieti-Pescara, Via Dei Vestini 5, 66100 Chieti, Italy

STMicroelectronics, ADG R&D, Stradale Primosole 50, 95121 Catania, Italy

Department of Sciences of Life, Kore University, Viale delle Olimpiadi, 94100 Enna, Italy

Funding

H2020, ECSEL-04-2015-Smart Health, Advancing Smart Optical Imaging and Sensing for Health (ASTONISH)

References (50)

Show source-provided references
1. Risk of mortality and cardiovascular disease associated with the ankle-brachial index: Systematic review10.1016/j.atherosclerosis.2006.03.011 ↗
2. Breen, P.P., Jayarathna, T., and Gargiulo, G.D. (2019, January 17–19). Live Demonstration: Morphic Sensor for Diagnosis of Peripheral Vascular Disease. Proceedings of the 2019 IEEE Biomedical Circuits and Systems Conference (BioCAS), Nara, Japan.10.1109/BIOCAS.2019.8918716 ↗
3. Associations of ankle-brachial index with clinical coronary heart disease, stroke and preclinical carotid and popliteal atherosclerosis:: The Atherosclerosis Risk in Communities (ARIC) Study10.1016/S0021-9150(97)06089-9 ↗
4. Influence of arterial disease on the systolic blood pressure gradients of the extremity10.1097/00000441-195008000-00001 ↗
5. Functional decline in peripheral arterial disease: Associations with the ankle brachial index and leg symptoms10.1001/jama.292.4.453 ↗
6. Ankle brachial index as a predictor of generalized atherosclerosis
7. Relationship of high and low ankle brachial index to all-cause and cardiovascular disease mortality10.1161/01.CIR.0000112642.63927.54 ↗
8. Measurement and interpretation of the ankle-brachial index10.1161/CIR.0b013e318276fbcb ↗
9. Oscillometric measurement of the ankle-brachial index10.1016/S0828-282X(08)70548-8 ↗
10. Automated oscillometric determination of the ankle–brachial index provides accuracy necessary for office practice10.1161/01.HYP.0000196686.85286.9c ↗
11. Comparison of ankle-brachial pressure index measurements using an automated oscillometric device with the standard doppler ultrasound technique10.1046/j.1445-2197.2003.02582.x ↗
12. Herráiz-Adillo, Á., Martínez-Vizcaíno, V., Cavero-Redondo, I., Álvarez-Bueno, C., Garrido-Miguel, M., and Notario-Pacheco, B. (2016). Diagnostic accuracy study of an oscillometric ankle-brachial index in peripheral arterial disease: The influence of oscillometric errors and calcified legs. PLoS ONE, 11.10.1371/journal.pone.0167408 ↗
13. Blood pressure measurement and treatment decisions: Masked and white-coat hypertension10.1161/CIRCRESAHA.118.313219 ↗
14. Photoelectric plethysmography for estimating cutaneous blood flow
15. Georgieva-Tsaneva, G., Gospodinova, E., Gospodinov, M., and Cheshmedzhiev, K. (2020). Portable sensor system for registration, processing and mathematical analysis of ppg signals. Appl. Sci., 10.10.3390/app10031051 ↗
16. Liu, S.-H., Wang, J.-J., Chen, W., Pan, K.-L., and Su, C.-H. (2020). Classification of photoplethysmographic signal quality with fuzzy neural network for improvement of stroke volume measurement. Appl. Sci., 10.10.3390/app10041476 ↗
17. Signal processing methods for pulse oximetry10.1016/0010-4825(95)00049-6 ↗
18. Measurements of scattering and absorption changes in muscle and brain10.1098/rstb.1997.0055 ↗
19. Exploiting neurovascular coupling: A Bayesian sequential Monte Carlo approach applied to simulated EEG fNIRS data10.1088/1741-2552/aa7321 ↗
20. Photoplethysmography and its application in clinical physiological measurement10.1088/0967-3334/28/3/R01 ↗
21. Lin, Y., Song, Z., and Yimin, Y. (2008, January 21–22). Study of pulse wave velocity noninvasive detecting instrument based on radial artery and finger photoplethysmography pulse wave. Proceedings of the 2008 International Symposium on Intelligent Information Technology Application Workshops, Shanghai, China.10.1109/IITA.Workshops.2008.102 ↗
22. Photoplethysmography and its detailed pulse waveform analysis for arterial stiffness
23. Independent determinants of second derivative of the finger photoplethysmogram among various cardiovascular risk factors in middle-aged men10.1291/hypres.30.1211 ↗
24. Photoplethysmographic signal waveform index for detection of increased arterial stiffness10.1088/0967-3334/35/10/2027 ↗
25. Gonzalez, R., Manzo, A., Delgado, J., Padilla, J.M., Trénor, B., and Saiz, J. (2008, January 14–17). A computer based photoplethysmographic vascular analyzer through derivatives. Proceedings of the 2008 Computers in Cardiology, Bologna, Italy.10.1109/CIC.2008.4749006 ↗
26. Data-driven assessment of cardiovascular ageing through multisite photoplethysmography and electrocardiography10.1016/j.medengphy.2019.07.009 ↗
27. Mcauliffe, J.D., and Blei, D.M. (2008, January 3–8). Supervised topic models. Proceedings of the Advances in Neural Information Processing Systems, Montreal, Canada.
28. Statistical analysis of fMRI time-series: A critical review of the GLM approach10.3389/fnhum.2011.00028 ↗
29. Perpetuini, D., Cardone, D., Filippini, C., Chiarelli, A.M., and Merla, A. (2019). Modelling impulse response function of functional infrared imaging for general linear model analysis of autonomic activity. Sensors, 19.10.3390/s19040849 ↗
30. Fast optical signals in the sensorimotor cortex: General Linear Convolution Model applied to multiple source–detector distance-based data10.1016/j.neuroimage.2013.07.021 ↗
31. Predictive value of the augmentation index derived vascular age in patients with newly diagnosed atherosclerosis10.1007/s00380-016-0868-0 ↗
32. Normal vascular aging: Differential effects on wave reflection and aortic pulse wave velocity: The Anglo-Cardiff Collaborative Trial (ACCT)10.1016/j.jacc.2005.07.037 ↗
33. Receiver-operating characteristic (ROC) plots: A fundamental evaluation tool in clinical medicine10.1093/clinchem/39.4.561 ↗
34. Vinciguerra, V., Ambra, E., Maddiona, L., Romeo, M., Mazzillo, M., Rundo, F., Fallica, G., di Pompeo, F., Chiarelli, A.M., and Zappasodi, F. (2018). PPG/ECG Multisite Combo System Based on SiPM Technology. Convegno Nazionale Sensori, Springer.10.1007/978-3-030-04324-7_44 ↗
35. Perpetuini, D., Chiarelli, A.M., Maddiona, L., Rinella, S., Bianco, F., Bucciarelli, V., Gallina, S., Perciavalle, V., Vinciguerra, V., and Merla, A. (2019). Multi-Site Photoplethysmographic and Electrocardiographic System for Arterial Stiffness and Cardiovascular Status Assessment. Sensors, 19.10.3390/s19245570 ↗
36. Perpetuini, D., Chiarelli, A.M., Vinciguerra, V., Vitulli, P., Rinella, S., Cardone, D., Bianco, F., Perciavalle, V., Gallina, S., and Fallica, G. (2019). Integrated multi-channel PPG and ECG system for cardiovascular risk assessment. Proceedings, 27.10.3390/proceedings2019027008 ↗
37. Characterization of a fiber-less, multichannel optical probe for continuous wave functional near-infrared spectroscopy based on silicon photomultipliers detectors: In-vivo assessment of primary sensorimotor response10.1117/1.NPh.4.3.035002 ↗
38. Vinciguerra, V., Ambra, E., Maddiona, L., Oliveri, S., Romeo, M.F., Mazzillo, M., Rundo, F., and Fallica, G. (2017, January 4–6). Progresses towards a processing pipeline in photoplethysmogram (PPG) based on SiPMs. Proceedings of the 2017 European Conference on Circuit Theory and Design (ECCTD), Catania, Italy.10.1109/ECCTD.2017.8093327 ↗
39. Moeinzadeh, H., Assad, J., Bifulco, P., Cesarelli, M., O’Loughlin, A., Shugman, I.M., and Gargiulo, G.D. (2019, January 24–28). Einthoven Unipolar Leads: Towards a better understanding of Wilson Central Terminal. Proceedings of the 2019 International Conference on Electrical Engineering Research & Practice (ICEERP), Sydney, Australia.10.1109/ICEERP49088.2019.8956990 ↗
40. Combining energy and Laplacian regularization to accurately retrieve the depth of brain activity of diffuse optical tomographic data10.1117/1.JBO.21.3.036008 ↗
41. Value of quantitative photoplethysmography for functional vascular diagnostics10.1159/000056362 ↗
42. Lazazzera, R., Belhaj, Y., and Carrault, G. (2019). A new wearable device for blood pressure estimation using photoplethysmogram. Sensors, 19.10.3390/s19112557 ↗
43. Practical Bayesian model evaluation using leave-one-out cross-validation and WAIC10.1007/s11222-016-9696-4 ↗
44. Hsu, H., and Lachenbruch, P.A. (2007). Paired t test. Wiley Encyclopedia of Clinical Trials, Wiley.
45. Cohen, P., West, S.G., and Aiken, L.S. (2014). Applied Multiple Regression/Correlation Analysis for the Behavioral Sciences, Psychology Press.10.4324/9781410606266 ↗
46. Statistical methods for assessing agreement between two methods of clinical measurement10.1016/S0140-6736(86)90837-8 ↗
47. Application of the Bland–Altman plot for interpretation of method-comparison studies: A critical investigation of its practice10.1093/clinchem/48.5.799 ↗
48. Why Bland–Altman plots should use X, not (Y + X)/2 when X is a reference method10.1002/sim.3086 ↗
49. The meaning and use of the area under a receiver operating characteristic (ROC) curve10.1148/radiology.143.1.7063747 ↗
50. Deep learning10.1038/nature14539 ↗