Improving the Performance of Doubly Fed Induction Generator Using Fault Tolerant Control—A Hierarchical Approach
Source abstract
Abstract
The growth of using wind energy on a large scale increases the demand for wind energy conversion machines (WECMs), among these converters, the doubly-fed induction generator (DFIG) is the favorite choice. However, DFIG is very sensitive to wind speed variations and grid faults during operation. In order to overcome these undesirable characteristics, this paper proposes a hierarchical fault tolerant control (FTC) to improve the performance of DFIG. The hierarchical fault tolerant control (FTC) approach consists of pitch angle control (PAC) and maximum power point tracking (MPPT). This hierarchical approach demonstrates the robust response under various (low, rated, and high) wind speed ranges and reduces the undesirable DC voltage overshoots during short-circuit disorder. The simulation results are summarized in a logical table, which depicts the order of controlling scheme and operation for a sustainable energy generation system. The proposed control scheme achieved the healthy and the robust dynamic response without deteriorating the grid power quality or stressing the converters, and approved the effectiveness to suppress the DC voltage overshoots and tolerate the lower down short-circuit disorder to its rated range.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Wind Turbine Control Systems · Multilevel Inverters and Converters · Microgrid Control and Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Automation, Huaiyin Institute of Technology, Huai’an 223003, China
Department of Electrical and Electronic Engineering, University of Kerbala, Kerbala 56001, Iraq
Jiangsu Smart Factory Engineering Research Centre, College of Management and Engineering, Huaiyin Institute of Technology, Huai’an 223003, China
School of Electronics and Information Engineering, Huaiyin Institute of Technology, Huai’an 223003, China
References (36)
Show source-provided references
1. Present trends and future prospects of asynchronous machines in renewable energy systems10.1016/j.rser.2016.11.069 ↗
2. Environmental impact and pollution-related challenges of renewable wind energy paradigm—A review10.1016/j.scitotenv.2019.05.274 ↗
3. A review on state of art development of model predictive control for renewable energy applications10.1016/j.rser.2017.03.058 ↗
4. Power quality improving based harmonical studies of a single phase step down bridge-cycloconverter
5. Economic analysis of a wind power plant: A case study for the Cappadocia region10.1007/s12206-018-0241-6 ↗
6. Energy and economic analysis of the wind turbine plant’s draft for the Aksaray city
7. Model-based fault detection, fault isolation and fault-tolerant control of a blade pitch system in floating wind turbines10.1016/j.renene.2017.12.102 ↗
8. Transient modeling and analysis of a DFIG based wind farm with supercapacitor energy storage10.1016/j.ijepes.2015.12.020 ↗
9. Fault detection and fault-tolerant control of actuators and sensors in distributed parameter systems10.1016/j.jfranklin.2017.03.004 ↗
10. DC Voltage Control for Fault Management in HVDC System10.1016/j.egypro.2015.11.427 ↗
11. Nonlinear maximum power point tracking control and modal analysis of DFIG based wind turbine10.1016/j.ijepes.2015.07.036 ↗
12. Parallel R-L configuration crowbar with series R-L circuit protection for LVRT strategy of DFIG under transient-state10.1016/j.epsr.2017.09.002 ↗
13. Modeling of complete fault ride-through processes for DFIG-Based wind turbines10.1016/j.renene.2017.10.076 ↗
14. Lagrangian-Based Approach for Non-linear Dynamic Control of an Islanded Power System
15. Perturbation observer based multiloop control for the DFIG-WT in multimachine power system10.1109/TPWRS.2014.2308900 ↗
16. Nazir, M.S., and Abdalla, A.N. (2019). The robustness assessment of doubly fed induction generator-wind turbine during short circuit. Energy Environ.10.1177/0958305X19880879 ↗
17. LQG control with reconfigurable state estimator under sensor and actuator failures10.3182/20070606-3-MX-2915.00023 ↗
18. A comparison of variation management strategies for wind power integration in different electricity system contexts10.1002/we.2198 ↗
19. Wave disturbance rejection for monopile offshore wind turbines10.1002/we.2273 ↗
20. Symmetrical Short Circuit Parameter Differences of Double Fed Induction Generator and Synchronous Generator based Wind Turbine
21. Real-time power switch fault diagnosis and fault-tolerant operation in a DFIG-based wind energy system10.1016/j.renene.2017.02.066 ↗
22. Fault detection and isolation of control moment gyros for satellite attitude control subsystem10.1016/j.ymssp.2019.106419 ↗
23. Optimization and control of offshore wind systems with energy storage10.1016/j.enconman.2018.07.079 ↗
24. Wahab, O.A., Bentahar, J., Otrok, H., and Mourad, A. (2017). Optimal load distribution for the detection of VM-based DDoS attacks in the cloud. IEEE Trans. Serv. Comput., 1-1.
25. Control of a small wind turbine in the high wind speed region10.1109/TPEL.2015.2508674 ↗
26. Symmetrical short-circuit parameters comparison of DFIG–WT
27. Kazemi Golkhandan, R., Aghaebrahimi, M.R., and Farshad, M. (2017). Control strategies for enhancing frequency stability by DFIGs in a power system with high percentage of wind power penetration. Appl. Sci., 7.10.3390/app7111140 ↗
28. Naderi, S.B., Davari, P., Zhou, D., Negnevitsky, M., and Blaabjerg, F. (2018). A Review on Fault Current Limiting Devices to Enhance the Fault Ride-Through Capability of the Doubly-Fed Induction Generator Based Wind Turbine. Appl. Sci., 8.10.20944/preprints201809.0538.v1 ↗
29. Bibliographical review on reconfigurable fault-tolerant control systems10.1016/j.arcontrol.2008.03.008 ↗
30. Kadhem, A.A., Wahab, N.I.A., Aris, I., Jasni, J., and Abdalla, A.N. (2017). Advanced wind speed prediction model based on a combination of weibull distribution and an artificial neural network. Energies, 10.10.3390/en10111744 ↗
31. Mahdi, A., Tang, W., and Wu, Q. (2012, January 22–26). Novel perturbation and observation algorithms for variable-speed wind turbine generator systems. Proceedings of the 2012 IEEE Power and Energy Society General Meeting, San Diego, CA, USA.10.1109/PESGM.2012.6512269 ↗
32. Mahdi, A., Tang, W., and Wu, Q. (2011, January 8–9). Derivation of a complete transfer function for a wind turbine generator system by experiments. Proceedings of the 2011 IEEE Power Engineering and Automation Conference, Wuhan, China.10.1109/PEAM.2011.6134789 ↗
33. Optimisation processes of energy efficiency for a drying plant: A case of study for Turkey10.1016/j.applthermaleng.2015.01.076 ↗
34. Energy and exergy analyze of PEM fuel cell: A case study of modeling and simulations10.1016/j.energy.2017.10.102 ↗
35. Renewable energy resources: Current status, future prospects and their enabling technology10.1016/j.rser.2014.07.113 ↗
36. Fault detection and diagnosis based on a hybrid dynamic simulator10.3182/20090630-4-ES-2003.00037 ↗