journal article·2020-11-29Open access

Comparative Study of Induction Motors of IE2, IE3 and IE4 Efficiency Classes in Pump Applications Taking into Account CO2 Emission Intensity

Victor Goman, Vladimir Prakht, Vadim Kazakbaev, Vladimir Dmitrievskii

Applied Sciences· Volume 10· Issue 23

Abstract

The high energy intensity of the modern industry and the threat of climate change determine the high urgency of increasing the energy efficiency of electric motors. In this paper, energy consumption, energy costs, payback periods, and CO2 emissions of 75 kW, 4 pole induction motors with direct grid supply in a fixed-speed pump unit are evaluated. Motors of the IE2, IE3, and IE4 efficiency classes according to IEC 60034-30-1 standard are compared in terms of life-time energy savings, payback period, and CO2 emissions. To carry out the analysis, polynomial interpolation of the data from the available manufacturer datasheets of the motors is used. It concluded that even though the initial investment cost of the IE4-motor is higher than that of IE3-motor, the IE4-motor is more profitable if more than 3 years of operation are considered and also provides significant reductions of CO2 emissions. The paper presents a calculation method of the aforementioned indicators which can be useful for companies, researchers, and engineers for quick assessment and selection of technical solutions.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Energy Efficiency and Management · Electric Motor Design and Analysis · Oil and Gas Production Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Nizhniy Tagil Technological Institute, Ural Federal University, 622000 Nizhniy Tagil, Russia

Department of Electrical Engineering, Ural Federal University, 620002 Yekaterinburg, Russia

Funding

Ministry of Science and Higher Education of the Russian Federation

References (36)

Show source-provided references
1. European Commission (2020, August 14). Study on Improving the Energy Efficiency of Pumps. Available online: http://www.jakob-albertsen.dk/komposit/Darmstadtrapport.pdf.
2. (2020, August 14). Rotating Electrical Machines-Part 30–32: Efficiency Classes of Variable Speed AC Motors (IE-Code) IEC 60034-30-2/ IEC: 2016–2012. Available online: https://webstore.iec.ch/publication/30830.
3. (2020, August 14). Rotating Electrical Machines-Part 30–31: Efficiency Classes of Line Operated AC Motors (IE code). IEC 60034-30-1/ Ed. 1. Available online: https://webstore.iec.ch/publication/136.
4. (2020, August 14). European Commission Regulation (EC) No. 640/2009 Implementing Directive 2005/32/ EC of the European Parliament and of the Council with Regard to Ecodesign Requirements for Electric Motors, 2009. Available online: https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX%3A32014R0004.
5. (2020, August 14). Commission Regulation (EU) 2019/1781 of 1 October 2019 Laying Down Ecodesign Requirements for Electric Motors and Variable Speed Drives Pursuant to Directive 2009/125/EC of the European Parliament and of the Council, Amending Regulation (EC) No 641/2009 with Regard to Ecodesign Requirements for Glandless Standalone Circulators and Glandless Circulators Integrated in Products and Repealing Commission Regulation (EC). Available online: https://eur-lex.europa.eu/legal-content/EN/TXT/PDF/?uri=CELEX:32019R1781&from=EN.
6. (2020, August 14). Efficiency Regulations for Motors: International Norms. Available online: https://www.nord.com/cms/media/documents/bw/S4700_6069202_4019_Screen.pdf.
7. Chodakowska, E., and Nazarko, J. (2020). Assessing the Performance of Sustainable Development Goals of EU Countries: Hard and Soft Data Integration. Energies, 13.10.3390/en13133439 ↗
8. Siksnelyte, I., and Zavadskas, E.K. (2019). Achievements of the European Union Countries in Seeking a Sustainable Electricity Sector. Energies, 12.10.3390/en12122254 ↗
9. 100% Renewable energy systems, climate mitigation and economic growth10.1016/j.apenergy.2010.03.001 ↗
10. Phillips, R., and Tieben, R. (2017, January 6–8). Improvement of Electric Motor Systems in Industry (IEMSI). Proceedings of the 10th International Conference on Energy Efficiency in Motor Driven Systems (EEMODS ‘17), Rome, Italy.
11. A comprehensive review on energy efficiency enhancement initiatives in centrifugal pumping system10.1016/j.apenergy.2016.08.070 ↗
12. Ahonen, T., Orozco, S.M., Ahola, J., and Tolvanen, J. (2016, January 5–9). Effect of electric motor efficiency and sizing on the energy efficiency in pumping systems. Proceedings of the 18th European Conference on Power Electronics and Applications (EPE’16 ECCE Europe), Karlsruhe, Germany.10.1109/EPE.2016.7695671 ↗
13. Van Rhyn, P., and Pretorius, J.H.C. (2015, January 11–13). Utilising high and premium efficiency three phase motors with VFDs in a public water supply system. Proceedings of the IEEE 5th International Conference on Power Engineering, Energy and Electrical Drives (POWERENG), Riga, Latvia.10.1109/PowerEng.2015.7266367 ↗
14. Induction Versus Permanent-Magnet Motors for Electric Submersible Pump Field and Laboratory Comparisons10.1109/TIA.2013.2288203 ↗
15. Kazakbaev, V., Prakht, V., Dmitrievskii, V., Ibrahim, M.N., Oshurbekov, S., and Sarapulov, S. (2019). Efficiency analysis of low electric power drives employing induction and synchronous reluctance motors in pump applications. Energies, 12.10.3390/en12061144 ↗
16. (2020, August 14). Commission Regulation (EC) July 22, 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with Regard to Ecodesign Requirements for Glandless Standalone Circulators and Glandless Circulators Integrated in Products, Amended by Commission Regulation (EU). Available online: https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX%3A02009R0641-20170109.
17. Europump (2020, August 14). Extended Product Approach for Pumps. Available online: http://europump.net/uploads/Extended%20Product%20Approach%20for%20Pumps%20-%20A%20Europump%20guide%20(27OCT2014).pdf.
18. Stoffel, B. (2015). Assessing the Energy Efficiency of Pumps and Pump Units. Background and Methodology, Elsevier.
19. (2020, August 14). Commission Regulation (EU) Implementing Directive 2009/125/EC of the European Parliament and of the Council with Regard to Ecodesign Requirements for Water Pumps. Available online: https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX%3A32012R0547.
20. Goman, V., Oshurbekov, S., Kazakbaev, V., Prakht, V., and Dmitrievskii, V. (2019). Energy Efficiency Analysis of Fixed-Speed Pump Drives with Various Types of Motors. Appl. Sci., 9.10.3390/app9245295 ↗
21. Oshurbekov, S., Kazakbaev, V., Prakht, V., Dmitrievskii, V., and Alecksey Paramonov (2020, January 4–7). Comparative Study of Energy Consumption of 15 kW Induction Motors of IE1 and IE2 Efficiency Classes in Pump Applications. Proceedings of the XI International Conference on Electrical Power Drive Systems (ICEPDS), Saint-Petersburg, Russia.10.1109/ICEPDS47235.2020.9249291 ↗
22. Technical Regulations of Eurasian Economic Union (2020, August 14). O Trebovaniyah k Energeticheskoy Effectivnosti Energopotreblyaushih Ustroistv. Available online: https://www.garant.ru/products/ipo/prime/doc/73240518/.
23. W22 High Efficiency IE2 75 kW 4P 280S/M 3Ph 380-415/660//460 V 50 Hz IC411-TEFC-B3T (2020, August 14). Product Details. Available online: https://www.weg.net/catalog/weg/CY/en/Electric-Motors/Low-Voltage-IEC-Motors/General-Purpose-ODP-TEFC/Cast-Iron-TEFC-General-Purpose/W22---Cast-Iron-TEFC-General-Purpose/W22-IE2/W22-IE2-75-kW-4P-280S-M-3Ph-380-415-660-460-V-50-Hz-IC411---TEFC---B3T/p/11130155.
24. W22 Premium Efficiency IE3 75 kW 4P 280S/M 3Ph 380-415/660//460 V 50 Hz IC411-TEFC- B3T (2020, August 14). Product Details. Available online: https://www.weg.net/catalog/weg/CI/en/Electric-Motors/Low-Voltage-IEC-Motors/General-Purpose-ODP-TEFC/Cast-Iron-TEFC-General-Purpose/W22---Cast-Iron-TEFC-General-Purpose/W22-IE3/W22-IE3-75-kW-4P-280S-M-3Ph-380-415-660-460-V-50-Hz-IC411---TEFC---B3T/p/12864750.
25. W22 Super Premium Efficiency IE4 75 kW 4P 280S/M 3Ph 400/690//460 V 50 Hz IC411-TEFC-B3T (2020, August 14). Product Details. Available online: https://www.weg.net/catalog/weg/CI/en/Electric-Motors/Low-Voltage-IEC-Motors/General-Purpose-ODP-TEFC/Cast-Iron-TEFC-General-Purpose/W22---Cast-Iron-TEFC-General-Purpose/W22-IE4/W22-IE4-75-kW-4P-280S-M-3Ph-400-690-460-V-50-Hz-IC411---TEFC---B3T/p/12774369.
26. (2020, August 14). NM, NMS, Close Coupled Centrifugal Pumps with Flanged Connections; Catalogue; Calpeda, 2018. Available online: https://www.calpeda.com/system/products/catalogue_50hzs/53/en/NM_NMS_EN2018.pdf?1549893188.
27. Ferreira, F.J.T.E., and de Almeida, A.T. (2016, January 4–7). Energy savings potential associated with stator winding connection mode change in induction motors. Proceedings of the XXII International Conference on Electrical Machines (ICEM), Lausanne, Switzerland.10.1109/ICELMACH.2016.7732915 ↗
28. CO2 Intensity of Electricity Generation (2020, August 14). European Environment Agency. Available online: https://www.eea.europa.eu/data-and-maps/data/co2-intensity-of-electricity-generation.
29. (2020, August 08). Directive 2012/27/EU of the European Parliament and of the Council of 25 October 2012 on Energy Efficiency, Amending Directives 2009/125/EC and 2010/30/EU and Repealing Directives 2004/8/EC and 2006/32/EC. Available online: https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=celex%3A32012L0027.
30. Empirical and dynamic primary energy factors10.1016/j.energy.2014.06.083 ↗
31. Final Report (2020, August 08). Evaluation of Primary Energy Factor Calculation Options for Electricity. Available online: https://ec.europa.eu/energy/sites/ener/files/documents/final_report_pef_eed.pdf.
32. Tucki, K., Orynycz, O., and Mitoraj-Wojtanek, M. (2020). Perspectives for Mitigation of CO2 Emission due to Development of Electromobility in Several Countries. Energies, 13.10.3390/en13164127 ↗
33. (2020, August 14). Eurostat Data for the Industrial Consumers in Germany. Available online: http://ec.europa.eu/eurostat/statistics-explained/index.php/Electricity_price_statistics#Electricity_prices_for_industrial_consumers.
34. (2020, August 14). Pump Life Cycle Costs: A Guide to LCC Analysis for Pumping Systems, Executive Summary. (2001) Hydraulic Institute (Parsippany, NJ); Europump (Brussels, Belgium); Office of Industrial Technologies Energy Efficiency and Renewable Energy U.S. Department of Energy (Washington, DC). Available online: https://searchworks.stanford.edu/view/4676735.
35. Waghmode, L., and Sahasrabudhe, A. (2010, January 15–18). A comparative study of life cycle cost analysis of pumps. Proceedings of the International Design Engineering Technical Conferences and Computers and Information in Engineering Conference (ASME 2010), Montreal, QC, Canada.
36. (2020, August 14). AC Electric Motor. Available online: https://www.acelectricmotor.co.uk/.