Accurate Estimation of Bicarbonate and Acetic Acid Concentrations with Wider Ranges in Anaerobic Media Using Classical FOS/TAC Titration Method
Source abstract
Abstract
The determination of a volatile fatty acid content (FOS) and total alkalinity (TAC) can be carried out using Nordmann’s FOS/TAC titration method developed in the 1970s. This two-point titration (pH = 5 and 4.4) can be simply implemented and is widely employed by both the academic and industrial worlds. However, the present study proves that Nordmann’s method is only valid in limited ranges, since the titration of one FOS and TAC has an impact on the determination of the other, especially in extreme conditions. The present work develops a numerical tool with Scilab simulating the acid–base equilibria of titration. The program is efficient in predicting the experimental equivalent volumes obtained from Nordmann’s method with different combinations of sodium acetate and sodium bicarbonate contents. The mean absolute percentage errors (MAPE) between the simulation and experiment are below 7%. Two new formulas are developed, considering both equivalent volumes at pH = 5 and 4.4 to calibrate FOS and TAC values. The proposed formulas show their good performance in predicting various combinations of FOS and TAC contents in an anaerobic digestate at TAC ranging from 0 to 20,000 mg CaCO3·L−1 and FOS ranging from 0 to 31,000 mg HAc·L−1.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Mineral Processing and Grinding · Chemical and Physical Properties in Aqueous Solutions · Anaerobic Digestion and Biogas Production
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
ESCOM, TIMR (Integrated Transformations of Renewable Matter), Centre de Recherches Royallieu, Université de Technologie de Compiègne, CS 60319, CEDEX, 60203 Compiègne, France
Institut Polytechnique UniLaSalle, Université d’Artois, ULR 7519, Rue Pierre Waguet, BP 30313, CEDEX, 60026 Beauvais, France
Cultimer France Producteurs Associés, ZA Les Rolandières, BP 52, 35120 Dol-de-Bretagne, France
Funding
Association Nationale de la Recherche et de la Technologie
References (29)
Show source-provided references
1. Temperature Phased Anaerobic Digestion (TPAD) of Organic Fraction of Municipal Solid Waste (OFMSW) and Digested Sludge (DS): Effect of Different Hydrolysis Conditions10.1016/j.wasman.2021.02.049 ↗
2. Volatile Acids by Direct Titration
3. Lili, M., Biró, G., Sulyok, E., Petis, M., Borbély, J., and Tamás, J. (2011, January 4–5). Novel Approach on the Basis of FOS/TAC Method. Proceedings of the Analele Universităţii din Oradea, Fascicula Protecţia Mediului, Oradea, Romania.
4. Modeling Volatile Fatty Acid Concentration in Livestock Manure–Based Anaerobic Digesters by Simple Titration10.1089/ees.2010.0253 ↗
5. Effects of Digestate Recirculation on a Two-Stage Anaerobic Digestion System, Particularly Focusing on Metabolite Correlation Analysis10.1016/j.biortech.2017.12.020 ↗
6. Die Überwachung Der Schlammfaulung
7. Voß, E., Weichgrebe, D., and Rosenwinkel, K. (2009, January 2–4). FOS/TAC–Deduction, Methods, Application and Significance. Proceedings of the Internationale Wis-Senschaftstagung, Biogas Science, Erding, Germany.
8. A Method for Approximation of the Volatile Acid Concentrations in Anaerobic Digesters
9. Measuring Anaerobic Sludge Digestion and Growth by a Simple Alkalimetric Titration
10. Improved Alkalimetric Monitoring for Anaerobic Digestion of High-Strength Wastes
11. Kapp, H. (1984). Schlammfaulung Mit Hohem Feststoffgehalt. Stuttgarter Berichte Zur Siedlungswasserwirtschaft, Kommissionsverlag Oldenbourg.
12. A 5 PH Point Titration Method for Determining the Carbonate and SCFA Weak Acid/Bases in Anaerobic Systems10.2166/wst.1993.0112 ↗
13. Lahav, O., Shlafman, E., Morgan, B.E., Loewenthal, R.E., and Tarre, S. (2002, January 22–25). Accurate On-Site Volatile Fatty Acids (VFA) Measurement in Anaerobic Digestion—Verification of a New Titrative Method. Proceedings of the VII Latin American Workshop and Symposium on Anaerobic Digestion, Merida, Mexico.
14. Rapid, Simple, and Accurate Method for Measurement of VFA and Carbonate Alkalinity in Anaerobic Reactors10.1021/es011169v ↗
15. A comparison of two simple titration procedures to determine volatile fatty acids in influents to waste-water and sludge treatment processes
16. An Improved Titration Model Reducing over Estimation of Total Volatile Fatty Acids in Anaerobic Digestion of Energy Crop, Animal Slurry and Food Waste10.1016/j.watres.2014.05.020 ↗
17. Titration Methodologies for Monitoring of Anaerobic Digestion in Developing Countries? A Review10.1002/jctb.1143 ↗
18. Monitoring Volatile Fatty Acids and Carbonate Alkalinity in Anaerobic Digestion: Titration Methodologies10.1002/ceat.201500293 ↗
19. Evaluation of the 5 and 8 PH Point Titration Methods for Monitoring Anaerobic Digesters Treating Solid Waste10.1080/09593330.2014.964334 ↗
20. Direct Method for Differentiating Bicarbonate and Acetate in Digester Control
21. Bicarbonate Determination in Complex Acid-base Solutions by a Back-titration Method10.1080/09593339009384887 ↗
22. American Public Health Association (1980). Standard Methods for the Examination of Water and Wastewater, American Public Health Association. [15th ed.].
23. Nativ, P., Gräber, Y., Aviezer, Y., and Lahav, O. (2021). A Simple and Accurate Approach for Determining the VFA Concentration in Anaerobic Digestion Liquors, Relying on Two Titration Points and an External Inorganic Carbon Analysis. ChemEngineering, 5.10.3390/chemengineering5020015 ↗
24. A Modified Two-Point Titration Method for the Determination of Volatile Fatty Acids in Anaerobic Systems10.1016/j.chemosphere.2018.04.038 ↗
25. Estimating VFA Concentrations in Prefermenters by Measuring PH10.1016/S0043-1354(97)00469-7 ↗
26. Combining PH and Electrical Conductivity Measurements to Improve Titrimetric Methods to Determine Ammonia Nitrogen, Volatile Fatty Acids and Inorganic Carbon Concentrations10.1016/j.watres.2016.03.017 ↗
27. Development and Validation of a Simplified Titration Method for Monitoring Volatile Fatty Acids in Anaerobic Digestion10.1016/j.wasman.2017.05.015 ↗
28. New Approach for Determination of Volatile Fatty Acid in Anaerobic Digester Sample10.1089/ees.2017.0190 ↗
29. A Novel Approach for Rapidly Measuring Volatile Fatty Acids in Anaerobic Process10.1016/j.watres.2020.115960 ↗