journal article·2024-08-02Open access

Heat Generated during Dental Implant Placement: A Scoping Review

Valerio Cimini, Alexandre Perez, Tommaso Lombardi, Roberto Di Felice

Applied Sciences· Volume 14· Issue 15

Abstract

Background: Osseointegration is fundamental to achieving successful implant therapy in dentistry. However, the heat generated during implant placement emerges as a critical factor predisposing to implant failure. Objective: This study aimed to analyze the different factors related to heat generation during implant placement, offering insights to clinicians in their daily clinical practice. Methods: Utilizing the PubMed, Web of Science, and Embase databases, we conducted an electronic search for articles published between January 2013 and December 2023. The analysis focused on several factors including bone type, drill shape, drill speed, drill material, drilling force, osteotomy depth, drill load, drilling technique (intermittent or continuous), presence of a surgical guide, irrigation methods, drill wear, and preparation tools available. Results: Initially, 2525 records were identified. After applying the inclusion and exclusion criteria and full-text assessment, 93 articles were included in this scoping review. Additionally, some articles published before 2013 were incorporated in the bibliography to ensure completeness of the review. Conclusions: Heat generation during implant placement arises from a complex interplay of multiple factors. While irrigation and bone hardness appear to be crucial determinants of heat generation during the osteotomy phase, the involvement of other factors remains less clear. Further studies are needed to better understand the precise contribution of these factors towards increasing temperature at the implant site.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Infrared Thermography in Medicine · 3D Printing in Biomedical Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Unit of Oral Surgery and Implantology, Division of Oral and Maxillofacial Surgery, Department of Surgery, Faculty of Medicine, University Hospitals of Geneva, University of Geneva, 1205 Geneva, Switzerland

Unit of Oral Medicine and Oral Maxillofacial Pathology, Division of Oral and Maxillofacial Surgery, Department of Surgery, Faculty of Medicine, University Hospitals of Geneva, University of Geneva, 1205 Geneva, Switzerland

Private Practice, Studio Roberto di Felice, Viale Buozzi 6, 63074 San Benedetto del Tronto, Italy

References (100+)

Show source-provided references
1. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
2. Factors associated with early and late failure of dental implants10.1111/j.2041-1626.2012.00162.x ↗
3. Biology of implant osseointegration
4. Implant failure rate and the prevalence of associated risk factors: A 6-year retrospective observational survey10.1051/mbcb/2021045 ↗
5. Histological evaluation of thermal damage to Osteocytes: A comparative study of conventional and ultrasonic-assisted bone grinding10.1016/j.medengphy.2021.01.009 ↗
6. Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbit10.1016/0022-3913(83)90174-9 ↗
7. Thermal injury to bone: A vital-microscopic description of heat effects10.1016/S0300-9785(82)80020-3 ↗
8. Effect of 50 to 60 °C Heating on Osseointegration of Dental Implants in Dense Bone: An: In Vivo: Histological Study10.1097/ID.0000000000000162 ↗
9. Effect of Temperature on the Dental Implant Osseointegration Development in Low-Density Bone: An In Vivo Histological Evaluation10.1097/ID.0000000000000204 ↗
10. PRISMA Extension for Scoping Reviews (PRISMA-ScR): Checklist and Explanation10.7326/M18-0850 ↗
11. Misch, C.E. (1993). Density of bone: Effect on treatment planning, surgical approach, and healing. Contemporary Implant Dentistry, Mosby.
12. Cortical bone thickness in dentate and edentulous human cadavers10.1902/jop.2007.060342 ↗
13. Distribution of Trabecular Bone Density in the Maxilla and Mandible10.1097/ID.0000000000000893 ↗
14. The thermal conductivity of cortical and cancellous bone10.22203/eCM.v035a03 ↗
15. Correlation between intraosseous thermal change and drilling impulse data during osteotomy within autonomous dental implant robotic system: An in vitro study10.1111/clr.14222 ↗
16. Ex vivo porcine study of thermal changes in the bone marrow region during osseodensification and osteotomy
17. The Evaluation of the Heat Generated by the Implant Osteotomy Preparation Using a Modified Method of the Measuring Temperature10.11607/jomi.3990 ↗
18. Thermal evaluation by infrared measurement of implant site preparation between single and gradual drilling in artificial bone blocks of different densities10.1016/j.ijom.2016.05.020 ↗
19. Comparison of conventional twist drill protocol and piezosurgery for implant insertion: An ex vivo study on different bone types10.1111/clr.12783 ↗
20. The assessment of temperature amplitude arising during the implant bed formation in relation to variable preparation parameters10.37190/ABB-01858-2021-02 ↗
21. Heat distribution in bone during preparation of implant sites: Heat analysis by real-time thermography
22. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites
23. Effects of drill cooling and bone structure on IMZ implant fixation
24. Gehrke, S.A., Treichel, T.L.E., Aramburu Junior, J., de Aza, P.N., and Prados-Frutos, J.C. (2020). Effects of the technique and drill design used during the osteotomy on the thermal and histological stimulation. Sci. Rep., 10.10.1038/s41598-020-77762-z ↗
25. Soldatos, N., Nelson-Rabe, L., Palanker, N., Angelov, N., Romanos, G., and Weltman, R. (2022). Temperature Changes during Implant Osteotomy Preparations in Fresh Human Cadaver Tibiae, Comparing Straight with Tapered Drills. Materials, 15.10.3390/ma15072369 ↗
26. A comparative study to evaluate the heat generated during osteotomy with conventional drill, trephine and alveolar expander
27. Infrared thermographic evaluation of rise in temperature with conventional versus trephine drills10.4103/jips.jips_252_20 ↗
28. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part I: Relationship between drill speed and heat production
29. Analysis of factors determining thermal changes at osteotomy site in dental implant placement—An in-vitro study10.4317/jced.57346 ↗
30. Benca, E., Ferrante, B., Zalaudek, M., Hirtler, L., Synek, A., Kainberger, F.M., Windhager, R., Brånemark, R., Hobusch, G.M., and Unger, E. (2021). Thermal Effects during Bone Preparation and Insertion of Osseointegrated Transfemoral Implants. Sensors, 21.10.3390/s21186267 ↗
31. Heat generation during implant drilling: The significance of motor speed10.1053/joms.2002.34992 ↗
32. In-vitro assessment of bone viability with different implant drill speeds10.1016/j.bjoms.2020.08.013 ↗
33. The Significance of Motor Speed on Heat Generation during Implant Drilling (Experimental Study on Bovine Bone)10.33899/rden.2009.9121 ↗
34. Heat and Sound Generation during Implant Osteotomy When Using Different Types of Drills in Artificial and Bovine Bone Blocks10.1563/aaid-joi-D-20-00361 ↗
35. Effects of a simplified drilling protocol at 50 rpm on heat generation under water-free conditions: An in vitro study10.5051/jpis.2201400070 ↗
36. Influence of bone density, drill diameter, drilling speed, and irrigation on temperature changes during implant osteotomies: An in vitro study10.1007/s00784-020-03398-y ↗
37. Chen, C.-H., Coyac, B.R., Arioka, M., Leahy, B., Tulu, U.S., Aghvami, M., Holst, S., Hoffmann, W., Quarry, A., and Bahat, O. (2019). A Novel Osteotomy Preparation Technique to Preserve Implant Site Viability and Enhance Osteogenesis. J. Clin. Med., 8.10.3390/jcm8020170 ↗
38. Thermal effects of various drill materials during implant site preparation—Ceramic vs. stainless steel drills: A comparative in vitro study in a standardised bovine bone model10.1111/clr.13685 ↗
39. Drilling- and withdrawing-related thermal effects of implant site preparation for ceramic and stainless steel twist drills in standardized bovine bone10.1111/cid.13151 ↗
40. Scarano, A., Lorusso, F., and Noumbissi, S. (2020). Infrared Thermographic Evaluation of Temperature Modifications Induced during Implant Site Preparation with Steel vs. Zirconia Implant Drill. J. Clin. Med., 9.10.3390/jcm9010148 ↗
41. Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: Twisted stainless steel and ceramic drills10.1111/j.1600-0501.2011.02248.x ↗
42. Thermal Variation during Osteotomy with Different Dental Implant Drills: A Standardized Study in Bovine Ribs10.1097/ID.0000000000000535 ↗
43. Effects of implant drill wear, irrigation, and drill materials on heat generation in osteotomy sites10.1563/AAID-JOI-D-13-00151 ↗
44. Improved Dental Implant Drill Durability and Performance Using Heat and Wear Resistant Protective Coatings10.1563/aaid-joi-D-16-00114 ↗
45. The Effect of Ceramic and Conventional Implant Drill Materials on Heat Generation in Osteotomy Sites10.1111/clr.76_13644 ↗
46. The Effect of Dental Implant Drills Materials on Heat Generation in Osteotomy Sites: A Systematic Review
47. Investigation of variable factors in drilling bone
48. Heat generation during implant site preparation: An in vitro study
49. Temperatures measured in human cortical bone when drilling10.2106/00004623-197254020-00008 ↗
50. The effects of drilling force on cortical temperatures and their duration: An in vitro study10.1016/S1350-4533(01)00016-9 ↗
51. Heat production during different ultrasonic and conventional osteotomy preparations for dental implants10.1111/j.1600-0501.2010.02126.x ↗
52. The effect of load on heat production, thermal effects and expenditure of time during implant site preparation—An experimental ex vivo comparison between piezosurgery and conventional drilling10.1111/clr.12077 ↗
53. Temperature rise during drilling through bone
54. Influence of different parameters on bone heating and drilling time in implantology10.1034/j.1600-0501.1997.080305.x ↗
55. Experimental Analysis of Temperature Differences during Implant Site Preparation: Continuous Drilling Technique Versus Intermittent Drilling Technique10.1563/aaid-joi-D-17-00077 ↗
56. Heat production by 3 implant drill systems after repeated drilling and sterilization10.1016/j.joms.2005.10.011 ↗
57. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: A study of drill durability
58. Efects of Mechanical and thermal fatigue on dental drill performance
59. Cortical bone drilling and thermal osteonecrosis10.1016/j.clinbiomech.2011.10.010 ↗
60. Kalidindi, V. (2014). Optimization of Drill Design and Coolant Systems during Dental Implant Surgery. [Master’s Thesis, University of Kentucky].
61. An experimental investigation on thermal exposure during bone drilling10.1016/j.medengphy.2012.03.002 ↗
62. Drilling- and withdrawing-related thermal changes during implant site osteotomies10.1111/cid.12091 ↗
63. Thermal Changes during Guided Flapless Implant Site Preparation: A Comparative Study10.11607/jomi.6029 ↗
64. Effects of Osteotomy Lengths on the Temperature Rise of the Crestal Bone during Implant Site Preparation10.1097/ID.0000000000000732 ↗
65. Influence of the implant drill design and sequence on temperature changes during site preparation10.11607/jomi.3747 ↗
66. Kim, Y., Ju, S., Kim, M., Park, M., Jun, S., and Ahn, J. (2019). Direct Measurement of Heat Produced during Drilling for Implant Site Preparation. Appl. Sci., 9.10.3390/app9091898 ↗
67. Intra-osseous heat generation during implant bed preparation with static navigation: Multi-factor in vitro study10.1111/clr.13728 ↗
68. Bone Healing Following Different Types of Osteotomy: Scanning Electron Microscopy (SEM) and Three-Dimensional SEM Analyses10.1017/S1431927616011971 ↗
69. The Stability and Survival Rate of Dental Implants after Preparation of the Site by Piezosurgery vs Conventional Drilling: A Systematic Review and Meta-Analysis10.11607/jomi.5913 ↗
70. Piezoelectric versus conventional implant site preparation: A systematic review and meta-analysis10.1111/cid.12555 ↗
71. Lamazza, L., Lollobrigida, M., Vozza, I., Palmieri, L., Stacchi, C., Lombardi, T., and De Biase, A. (2020). Piezoelectric Implant Site Preparation: Influence of Handpiece Movements on Temperature Elevation. Materials, 13.10.3390/ma13184072 ↗
72. Heat Generation during Initial Osteotomy for Implant Site Preparation: An In Vitro Measurement Study10.1007/s12663-022-01800-8 ↗
73. Comparison of heat production and bone architecture changes in the implant site preparation with compressive osteotomes, osseodensification technique, piezoelectric devices, and standard drills: An ex vivo study on porcine ribs10.1007/s10266-022-00730-8 ↗
74. Bone heat generated using conventional implant drills versus piezosurgery unit during apical cortical plate perforation10.1002/JPER.17-0502 ↗
75. Intracanal temperature changes during bone preparations close to and penetrating the inferior alveolar canal: Drills versus piezosurgery10.1016/j.jcms.2017.07.007 ↗
76. Comparison of Er:YAG laser, piezoelectric, and drill osteotomy for dental implant site preparation: A biomechanical and histological analysis in sheep10.1002/lsm.20944 ↗
77. Evaluation of temperature and osteotomy speed with piezoelectric system10.23736/S2724-6329.20.04328-9 ↗
78. Ultrastructural analysis of bone tissue irradiated by Er:YAG Laser10.1002/lsm.10110 ↗
79. Gabrić, D., Aumiler, D., Vuletić, M., Gjorgievska, E., Blašković, M., Mladenov, M., and Pavlić, V. (2021). Thermal Evaluation by Infrared Thermography Measurement of Osteotomies Performed with Er:YAG Laser, Piezosurgery and Surgical Drill—An Animal Study. Materials, 14.10.3390/ma14113051 ↗
80. Comparative Study on the Cutting Effectiveness and Heat Generation of Rotary Instruments Versus Piezoelectric Surgery Tips Using Scanning Electron Microscopy and Thermal Analysis10.11607/jomi.5806 ↗
81. An image-guided planning system for endosseous oral implants10.1109/42.736056 ↗
82. Internal bone temperature change during guided surgery preparations for dental implants: An in vitro study10.11607/jomi.2854 ↗
83. Evaluation of Bone Heating, Drill Deformation, and Drill Roughness after Implant Osteotomy: Guided Surgery and Classic Drilling Procedure10.11607/jomi.2919 ↗
84. Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites—Thermographic analysis on bovine ribs10.2298/VSP141208041M ↗
85. Effect of the use of a surgical guide on heat generation during implant placement: A comparative in vitro study10.17219/dmp/127605 ↗
86. Comparison of heat generation between guided and conventional implant surgery for single and sequential drilling protocols—An in vitro study10.1111/clr.13398 ↗
87. Effect of different dental implant drilling template designs on heat generation during osteotomy—An in vitro study10.1111/clr.13864 ↗
88. Effect of Guiding Sleeve Design on Intraosseous Heat Generation During Implant Site Preparation (In Vitro Study)10.1111/jopr.13370 ↗
89. Thermal changes during implant site preparation with a digital surgical guide and slot design drill: An ex vivo study using a bovine rib model10.5051/jpis.2106040302 ↗
90. Abuhajar, E., Salim, N.A., Sallam, M., Jarab, F., and Satterthwaite, J.D. (2023). The impact of surgical guide design and bone quality on heat generation during pilot implant site preparation: An in vitro study. BMC Oral Health, 23.10.1186/s12903-023-02961-9 ↗
91. Parvizi, S., Cameron, A., Tadakamadla, S., Figueredo, C.M.S., and Reher, P. (2023). A Novel Irrigation System to Reduce Heat Generation during Guided Implantology: An In Vitro Study. J. Clin. Med., 12.10.20944/preprints202305.0711.v1 ↗
92. Stocchero, M., Sivolella, S., Brunello, G., Zoppello, A., Cavallin, F., and Biasetto, L. (2021). Bone Temperature Variation Using a 3D-Printed Surgical Guide with Internal Irrigation. Appl. Sci., 11.10.3390/app11062588 ↗
93. External cooling efficiently controls intraosseous temperature rise caused by drilling in a drilling guide system: An in vitro study10.1016/j.bjoms.2015.07.013 ↗
94. The effect of guided flapless implant procedure on heat generation from implant drilling10.1016/j.jcms.2013.11.002 ↗
95. 3D printed implant surgical guides with internally routed irrigation for temperature reduction during osteotomy preparation: A pilot study10.1111/jerd.12847 ↗
96. Addition of an irrigation channel to a surgical template to facilitate cooling during implant osteotomy10.1016/j.prosdent.2020.05.019 ↗
97. Guided Implant Placement Using an Internally Cooling Surgical Template: A Technical Note10.1563/aaid-joi-D-19-00312 ↗
98. Thermal effects of a combined irrigation method during implant site drilling. A standardized in vitro study using a bovine rib model10.1111/clr.12032 ↗
99. Effect of irrigation and stainless steel drills on dental implant bed heat generation10.1007/s10856-015-5412-8 ↗
100. Insufficient irrigation induces peri-implant bone resorption: An in vivo histologic analysis in sheep10.1111/clr.12127 ↗