journal article·2020-10-22Open access

Multifrequency Impedance Method Based on Neural Network for Root Canal Length Measurement

Xiaoyue Qiao, Zheng Zhang, Xin Chen

Applied Sciences· Volume 10· Issue 21

Abstract

Root canal therapy is the most fundamental and effective approach for treating endodontics and periapicalitis. The length of the root canal must be accurately measured to clean the pathogenic substances in it. This study aims to present a multifrequency impedance method based on a neural network for root canal length measurement. A circuit system was designed which generates a current of frequencies from 100 Hz to 20 kHz in order to augment the data of impedance ratios with different combinations of frequencies. Several impedance ratios and other quantified characteristics, such as the type of tooth and file, were selected as features to train a neural network model that could predict the distance between the file and apical foramen. The model uses leave-one-out cross-validation, adopts the Adam optimizer and regularization, and has two hidden layers with nine and five nodes, respectively. The neural network-based multifrequency impedance method exhibits nearly 95% accuracy, compared with the dual-frequency impedance ratio method (which demonstrated no more than 85% accuracy in some situations). This method may eliminate the influence of human and environmental factors on measurement of the root canal length, thereby increasing measurement robustness.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrical and Bioimpedance Tomography · Dental Radiography and Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China

Funding

National Key Research and Development Program of China · Major projects of Science and Technology Commission of Shanghai

References (31)

Show source-provided references
1. Electronic apex locators10.1111/j.1365-2591.2004.00835.x ↗
2. Minetti, E., Palermo, A., Ferrante, F., Schmitz, J.H., Lung Ho, H.K., Hann, D., Ng, S., Giacometti, E., Gambardella, U., and Contessi, M. (2019). Autologous Tooth Graft after Endodontical Treated Used for Socket Preservation: A Multicenter Clinical Study. Appl. Sci., 9.10.3390/app9245396 ↗
3. Razumova, S., Brago, A., Howijieh, A., Barakat, H., Kozlova, Y., and Baykulova, M. (2020). Evaluation of Cross-Sectional Root Canal Shape and Presentation of New Classification of Its Changes Using Cone-Beam Computed Tomography Scanning. Appl. Sci., 10.10.3390/app10134495 ↗
4. Lee, J., Lee, S.H., Hong, J.R., Kum, K.Y., Oh, S., Al-Ghamdi, A.S., Al-Ghamdi, F.A., Mandorah, A.O., Jang, J.H., and Chang, S.W. (2020). Three-Dimensional Analysis of Root Anatomy and Root Canal Curvature in Mandibular Incisors Using Micro-Computed Tomography with Novel Software. Appl. Sci., 10.10.3390/app10124385 ↗
5. Performance of theWorking Length Determination using Cone Beam Computed Tomography, Radiography and Electronic Apex Locator, in Comparisons to Actual Length
6. Comparison of electrical equivalent circuits of human tooth used for measuring the root canal length10.1080/00051144.2011.11828402 ↗
7. Electrical impedance measurements of root canal length10.1111/j.1600-9657.1997.tb00025.x ↗
8. New principle and method for measuring the root canal length10.1016/S0099-2399(83)80105-8 ↗
9. Electronic canal length measurement10.1016/S1079-2104(05)80288-4 ↗
10. New electronic canal measuring device based on the ratio method10.1016/S0099-2399(06)80053-1 ↗
11. An overview of electronic apex locators: Part 210.1038/sj.bdj.2013.215 ↗
12. Evaluation of the reliability of cone-beam computed tomography scanning and electronic apex locator measurements in working length determination of teeth with large periapical lesions10.1016/j.joen.2016.06.010 ↗
13. The fundamental operating principles of electronic root canal length measurement devices
14. An evaluation of root ZX and iPex apex locators: An in vivo study10.1016/j.joen.2011.02.002 ↗
15. An in vivo comparison of two frequency-based electronic apex locators10.1097/00004770-200308000-00002 ↗
16. A general regression neural network10.1109/72.97934 ↗
17. Neural network methods for natural language processing
18. Recognizing the gradual changes in sEMG characteristics based on incremental learning of wavelet neural network ensemble10.1109/TIE.2016.2593693 ↗
19. A novel deep learning approach with data augmentation to classify motor imagery signals10.1109/ACCESS.2019.2895133 ↗
20. An introduction to variable and feature selection
21. Ruder, S. (2016). An overview of gradient descent optimization algorithms. arXiv.
22. The calculation of posterior distributions by data augmentation10.1080/01621459.1987.10478458 ↗
23. Regularization and variable selection via the elastic net10.1111/j.1467-9868.2005.00503.x ↗
24. Performance evaluation of classification algorithms by k-fold and leave-one-out cross validation10.1016/j.patcog.2015.03.009 ↗
25. Accuracy of root canal length determination with the impedance ratio method10.1111/j.1365-2591.2009.01589.x ↗
26. Development of a frequency-dependent-type apex locator with automatic compensation10.1615/CritRevBiomedEng.v28.i34.200 ↗
27. Root canal length measurement in teeth with electrolyte compensation10.1007/BF02348125 ↗
28. Clinical efficacy of electronic apex locators: Systematic review10.1016/j.joen.2014.03.011 ↗
29. Accuracy of five electronic foramen locators with different operating systems: An ex vivo study10.1590/1678-7757201302188 ↗
30. Comparative evaluation of working length with digital radiography and third generation electronic apex locator
31. Machine Learning in Medicine10.1161/CIRCULATIONAHA.115.001593 ↗