Characterization of Ultra-High-Dose Rate Electron Beams with ElectronFlash Linac

Lucia Giuliano, Gaia Franciosini, Luigi Palumbo, Lilia Aggar, Marie Dutreix, Luigi Faillace, Vincent Favaudon, Giuseppe Felici, Federica Galante, Andrea Mostacci, Mauro Migliorati, Matteo Pacitti, Annalisa Patriarca, Sophie Heinrich

Applied Sciences· Volume 13· Issue 1

Abstract

Purpose: The electron linac ElectronFlash installed at Institut Curie (Orsay, France) is entirely dedicated to FLASH irradiation for radiobiological and pre-clinical studies. The system was designed to deliver an ultra-high-dose rate per pulse (UHDR) (above 106 Gy/s) and a very high average dose rate at different energies and pulse durations. A campaign of tests and measurements was performed to obtain a full reliable characterizations of the electron beam and of the delivered dose, which are necessary to the radiobiological experiments. Methods: A Faraday cup was used to measure the electron charges in a single RF pulse. The percentage depth dose (PDD) and the transverse dose profiles, at the energies of 5 MeV and 7 MeV, were evaluated employing Gafchromic films EBT-XD for two Poly-methylmethacrylate (PMMA) applicators with irradiation sizes of 30 mm and 120 mm, normally used for in vivo and in vitro experiments, respectively. The results were compared with Monte Carlo (MC) simulations. Results: The measurements were performed during a period of a few months in which the experimental set up was adapted and tuned in order to characterize the electron beam parameters and the values of delivered doses before the radiobiological experiments. The measurements showed that the dose parameters, obtained at the energy of 5 MeV and 7 MeV with different applicators, fulfill the FLASH regime, with a maximum value of an average dose rate of 4750 Gy/s, a maximum dose per pulse of 19 Gy and an instantaneous dose rate up to 4.75 ×106 Gy/s. By means of the PMMA applicators, a very good flatness of the dose profiles was obtained at the cost of a reduced total current. The flatness of the large field is reliable and reproducible in radiobiological experiments. The measured PDD and dose profiles are in good agreement with Monte Carlo simulations with more than 95% of the gamma-index under the thresholds of 3 mm/3%. Conclusions: The results show that the system can provide UHDR pulses totally satisfying the FLASH requirements with very good performances in terms of beam profile flatness for any size of the fields. The monitoring of electron beams and the measurement of the dose parameters played an important role in the in vivo and in vitro irradiation experiments performed at the Institut Curie laboratory.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiation Therapy and Dosimetry · Radiation Effects and Dosimetry · Advanced Radiotherapy Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Dipartimento SBAI, Università di Roma La Sapienza, Via A. Scarpa 14, 00161 Roma, Italy

INFN Sezione di Roma, 00185 Roma, Italy

Institut Curie, PSL Research University, INSERM U1021/UMR3347, 91401 Orsay, France

INFN Laboratori Nazionali di Frascati, 00044 Frascati, Italy

S.I.T. Sordina IORT Technology S.p.A., 04011 Aprilia, Italy

Proton Therapy Centre, Centre Universitaire, Institut Curie, PSL Research University, 91898 Orsay, France

References (30)

Show source-provided references
1. Survival of mammalian cells exposed to X rays at ultra-high dose-rates10.1259/0007-1285-42-494-102 ↗
2. Effects of dose-rate on the radiation response of rat skin10.1080/09553007414551221 ↗
3. High Dose-rate Dependence of Early Skin Reaction in Mouse10.1080/09553008014551031 ↗
4. The constant low oxygen concentration in all the target cells for mouse tail radionecrosis10.2307/3575852 ↗
5. Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in mice10.1126/scitranslmed.3008973 ↗
6. The advantage of FLASH radiotherapy confirmed in mini-pig and cat cancer patients10.1158/1078-0432.CCR-17-3375 ↗
7. Irradiation in a FLASH: Unique sparing of memory in mice after whole brain irradiation with dose rates above 100 Gy/s10.1016/j.radonc.2017.05.003 ↗
8. Treatment of a first patient with FLASH-radiotherapy10.1016/j.radonc.2019.06.019 ↗
9. Ultra-High Dose Rate (FLASH) Radiotherapy: Silver Bullet or Fool’s Gold?10.3389/fonc.2019.01563 ↗
10. Radiobiology of the FLASH effect10.1002/mp.15184 ↗
11. High dose-per-pulse electron beam dosimetry: Commissioning of the Oriatron eRT6 prototype linear accelerator for preclinical use10.1002/mp.12713 ↗
12. Commissioning of an ultra-high dose rate pulsed electron beam medical LINAC for FLASH RT preclinical animal experiments and future clinical human protocols10.1002/mp.14885 ↗
13. Modifying a clinical linear accelerator for delivery of ultra-high dose rate irradiation10.1016/j.radonc.2019.01.031 ↗
14. Experimental platform for ultra-high dose rate FLASH irradiation of small animals using a clinical linear accelerator10.1016/j.ijrobp.2016.09.018 ↗
15. Monitoring electron energies during FLASH irradiations10.1088/1361-6560/abd672 ↗
16. Simulation and experimental validation of a prototype electron beam linear accelerator for preclinical studies10.1016/j.ejmp.2019.03.016 ↗
17. FLASH Radiotherapy With Electrons: Issues Related to the Production, Monitoring, and Dosimetric Characterization of the Beam10.3389/fphy.2020.570697 ↗
18. Compact S-band linear accelerator system for ultrafast, ultrahigh dose-rate radiotherapy10.1103/PhysRevAccelBeams.24.050102 ↗
19. (2022, December 30). S-band Magnetron Company. Available online: https://www.teledyne-e2v.com.
20. Albedo factor determination of some selected 3d alloy samples10.1016/j.apradiso.2020.109505 ↗
21. Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization10.1063/1.3610649 ↗
22. A dosimetric system for quantitative cell irradiation experiments with laser-accelerated protons10.1088/0031-9155/56/6/002 ↗
23. Development and first experimental tests of Faraday cup array10.1063/1.4859496 ↗
24. Time-resolved dosimetry of pulsed electron beams in very high dose-rate, FLASH irradiation for preclinical studies10.1016/j.nima.2019.162537 ↗
25. (2022, December 30). Available online: www.gafchromic.com.
26. Andreo, P., Burns, D.T., Hohlfeld, K., Huq, M.S., Kanai, T., Laitano, F., Smyth, V., Vynckier, S.P., Andreo, D., and Burns, K.H. (2020). IAEA TRS-398—Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water, IAEA.
27. Ferrari, A., Sala, P.R., Fasso, A., and Ranft, J. (2005). FLUKA: A Multi-Particle Transport Code (Program version 2005), INFN-TC-05-11.10.2172/877507 ↗
28. The FLUKA Code: An Accurate Simulation Tool for Particle Therapy10.3389/fonc.2016.00116 ↗
29. Young, L.M. (1996). Los Alamos National Laboratory Report No. LA-UR-96-1835.
30. A technique for the quantitative evaluation of dose distributions10.1118/1.598248 ↗