journal article·2018-10-25Open access

A Review on Fault Current Limiting Devices to Enhance the Fault Ride-Through Capability of the Doubly-Fed Induction Generator Based Wind Turbine

Seyed Behzad Naderi, Pooya Davari, Dao Zhou, Michael Negnevitsky, Frede Blaabjerg

Applied Sciences· Volume 8· Issue 11

Abstract

The doubly-fed induction generator has significant features compared to the fixed speed wind turbine, which has popularised its application in power systems. Due to partial rated back-to-back converters in the doubly-fed induction generator, fault ride-through capability improvement is one of the important subjects in relation to new grid code requirements. To enhance the fault ride-through capability of the doubly-fed induction generator, many studies have been carried out. Fault current limiting devices are one of the techniques utilised to limit the current level and protect the switches, of the back-to-back converter, from over-current damage. In this paper, a review is carried out based on the fault current limiting characteristic of fault current limiting devices, utilised in the doubly-fed induction generator. Accordingly, fault current limiters and series dynamic braking resistors are mainly considered. Operation of all configurations, including their advantages and disadvantages, is explained. Impedance type and the location of the fault current limiting devices are two important factors, which significantly affect the behaviour of the doubly-fed induction generator in the fault condition. These two factors are studied by way of simulation, basically, and their effects on the key parameters of the doubly-fed induction generator are investigated. Finally, future works, in respect to the application of the fault current limiter for the improvement of the fault ride-through of the doubly-fed induction generator, have also been discussed in the conclusion section.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Wind Turbine Control Systems · HVDC Systems and Fault Protection · Wind Energy Research and Development

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Engineering, University of Tasmania, Hobart, TAS 7005, Australia

The Department of Energy Technology, Aalborg University, 9220 Aalborg, Denmark

References (47)

Show source-provided references
1. A review of grid code technical requirements for wind farms10.1049/iet-rpg.2008.0070 ↗
2. Fault ride-through capability of DFIG wind turbines10.1016/j.renene.2006.10.008 ↗
3. Wind turbines based on doubly fed induction generator under asymmetrical voltage dips10.1109/TEC.2007.914317 ↗
4. Ma, K. (2015). Power Electronics For The Next Generation Wind Turbine System, Springer.10.1007/978-3-319-21248-7 ↗
5. Netz, E. (2006). Grid Code; High and Extra High Voltage, E. ON Netz GmbH. Available online: https://www.eon.com/en.html.
6. Doubly-fed induction generator based wind turbines: A comprehensive review of fault ride-through strategies10.1016/j.rser.2015.01.064 ↗
7. Duong, M.Q., Sava, G.N., Grimaccia, F., Leva, S., Mussetta, M., Costinas, S., and Golovanov, N. (2015, January 7–9). Improved LVRT based on coordination control of active crowbar and reactive power for doubly fed induction generators. Proceedings of the ATEE 2015 9th International Symposium on Advanced Topics in Electrical Engineering, Bucharest, Rome.10.1109/ATEE.2015.7133896 ↗
8. A parallel capacitor control strategy for enhanced frt capability of DFIG10.1109/TSTE.2014.2371925 ↗
9. Evaluation of the performance of a dc-link brake chopper as a dfig low-voltage fault-ride-through device10.1109/TEC.2013.2261301 ↗
10. A low component count series voltage compensation scheme for dfig wts to enhance fault ride-through capability10.1109/TEC.2014.2351799 ↗
11. Unbalanced voltage sag ride-through of a doubly fed induction generator wind turbine with series grid-side converter10.1109/TIA.2009.2027540 ↗
12. Control of a DFIG-based wind energy conversion system operating under harmonically distorted unbalanced grid voltage along with nonsinusoidal rotor injection conditions10.1016/j.enconman.2014.03.078 ↗
13. Dynamic behavior of the doubly fed induction generator during three-phase voltage dips10.1109/TEC.2006.878241 ↗
14. LVRT capability enhancement of DFIG with switch-type fault current limiter10.1109/TIE.2014.2326997 ↗
15. Low voltage ride-through enhancement of DFIG-based wind turbine using DC link switchable resistive type fault current limiter10.1016/j.ijepes.2016.10.001 ↗
16. A comprehensive LVRT control strategy for DFIG wind turbines with enhanced reactive power support10.1109/TPWRS.2013.2240707 ↗
17. Efficient control scheme of wind turbines with doubly fed induction generators for low-voltage ride-through capability enhancement10.1049/iet-rpg.2009.0072 ↗
18. A novel fault-tolerant DFIG-based wind energy conversion system for seamless operation during grid faults10.1109/TPWRS.2013.2290047 ↗
19. A fault tolerant doubly fed induction generator wind turbine using a parallel grid side rectifier and series grid side converter10.1109/TPEL.2008.921179 ↗
20. Coordinated reactive power control of a large wind farm and a STATCOM using heuristic dynamic programming10.1109/TEC.2008.2001456 ↗
21. Qiao, W., Harley, R.G., and Venayagamoorthy, G.K. (Novermber, January 29). Effects of FACTS devices on a power system which includes a large wind farm. Proceedings of the 2006 IEEE PES Power Systems Conference and Exposition, Atlanta, GA, USA.10.1109/PSCE.2006.296264 ↗
22. A fault ride-through technique of DFIG wind turbine systems using dynamic voltage restorers10.1109/TEC.2011.2158102 ↗
23. Hagh, M.T., Naderi, S.B., and Jafari, M. (December, January 29). Application of non-superconducting fault current limiter to improve transient stability. Proceedings of the 2010 IEEE International Conference on Power and Energy, Kuala Lumpur, Malaysia.10.1109/PECON.2010.5697660 ↗
24. Optimum resistive type fault current limiter: An efficient solution to achieve maximum fault ride-through capability of fixed-speed wind turbines during symmetrical and asymmetrical grid faults10.1109/TIA.2016.2611665 ↗
25. Voltage sag compensation of point of common coupling (PCC) using fault current limiter10.1109/TPWRD.2011.2161496 ↗
26. Naderi, S.B., Negnevistky, M., Jalilian, A., and Hagh, M.T. (2016, January 17–21). Non-controlled fault current limiter to improve fault ride through capability of DFIG-based wind turbine. Proceedings of the 2016 IEEE Power and Energy Society General Meeting (PESGM), Boston, MA, USA.10.1109/PESGM.2016.7741624 ↗
27. Mardani, M., and Fathi, S.H. (2015, January 3–4). Fault current limiting in a wind power plant equipped with a DFIG using the interface converter and an optimized located FCL. Proceedings of the 6th Power Electronics, Drive Systems & Technologies Conference (PEDSTC2015), Tehran, Iran.10.1109/PEDSTC.2015.7093296 ↗
28. Evaluation of the performance of BTFCLS for enhancing lvrt capability of DFIG10.1109/TPEL.2014.2340852 ↗
29. Transient stability augmentation of PV/DFIG/SG-based hybrid power system by nonlinear control-based variable resistive FCL10.1109/TSTE.2015.2463286 ↗
30. Controllable resistive type fault current limiter (CR-FCL) with frequency and pulse duty-cycle10.1016/j.ijepes.2014.03.011 ↗
31. Rashid, G., and Ali, M.H. (2016, January 2–5). Application of parallel resonance fault current limiter for fault ride through capability augmentation of DFIG based wind farm. Proceedings of the 2016 IEEE/PES Transmission and Distribution Conference and Exposition (T & D), Dallas, TX, USA.10.1109/TDC.2016.7519858 ↗
32. Parallel-resonance-type fault current limiter10.1109/TIE.2012.2196899 ↗
33. Enhancing low-voltage ride-through capability and smoothing output power of DFIG with a superconducting fault-current limiter magnetic energy storage system10.1109/TEC.2012.2187654 ↗
34. Fault current limiter-battery energy storage system for the doubly-fed induction generator: Analysis and experimental verification10.1049/iet-gtd.2014.1158 ↗
35. Fault ride-through capability improvement of DFIG-based wind turbine by employing a voltage-compensation-type active SFCL10.1109/CJECE.2015.2406665 ↗
36. Transient stability improvement of doubly fed induction generator based variable speed wind generator using DC resistive fault current limiter10.1049/iet-rpg.2015.0150 ↗
37. Hossain, M., and Ali, H. (2016, January 2–5). Asymmetric fault ride through capability enhancement of DFIG based variable speed wind generator by DC resistive fault current limiter. Proceedings of the 2016 IEEE/PES Transmission and Distribution Conference and Exposition (T & D), Dallas, TX, USA.10.1109/TDC.2016.7519865 ↗
38. Fault ride-through capability enhancement of DFIG-based wind turbine with a flux-coupling-type SFCL employed at different locations10.1109/TASC.2014.2373511 ↗
39. Cooperative control of SFCL and reactive power for improving the transient voltage stability of grid-connected wind farm with DFIGs10.1109/TASC.2016.2574344 ↗
40. Cooperative control of SFCL and SMES for enhancing fault ride through capability and smoothing power fluctuation of dfig wind farm
41. Improving low-voltage ride-through performance and alleviating power fluctuation of DFIG wind turbine in dc microgrid by optimal smes with fault current limiting function
42. Conceptual design and evaluation of a resistive-type SFCL for efficient fault ride through in a DFIG
43. Integrated protection of DFIG-based wind turbine with a resistive-type SFCL under symmetrical and asymmetrical faults
44. Improved fault ride through strategy for doubly fed induction generator based wind turbines under both symmetrical and asymmetrical grid faults10.1049/iet-rpg.2015.0586 ↗
45. A series-dynamic-resistor-based converter protection scheme for doubly-fed induction generator during various fault conditions10.1109/TEC.2009.2037970 ↗
46. Enhancing DFIG wind turbine during three-phase fault using parallel interleaved converters and dynamic resistor
47. Wind farms fault ride through using DFIG with new protection scheme10.1109/TSTE.2011.2175756 ↗