Factors Influencing Primary and Secondary Implant Stability—A Retrospective Cohort Study with 582 Implants in 272 Patients
Source abstract
Abstract
The success rate of dental implants depends on primary and secondary stability. We investigate predictive factors for future risk stratification models. We retrospectively analyze 272 patients with a total of 582 implants. Implant stability is measured with resonance frequency analysis and evaluated based on the implant stability quotient (ISQ). A linear regression model with regression coefficients (reg. coeff.) and its 95% confidence interval (95% CI) is applied to assess predictive factors for implant stability. Implant diameter (reg. coeff.: 3.28; 95% CI: 1.89–4.66, p < 0.001), implant length (reg. coeff.: 0.67, 95% CI: 0.26–1.08, p < 0.001), and implant localization (maxillary vs. mandibular, reg. coeff.: −7.45, 95% CI: −8.70–(−6.20), p < 0.001) are significant prognostic factors for primary implant stability. An increase in ISQ between insertion and exposure is significantly correlated with healing time (reg. coeff.: 0.11, 95% CI: 0.04–0.19). Patients with maxillary implants have lower ISQ at insertion but show a higher increase in ISQ after insertion than patients with mandibular implants. We observe positive associations between primary implant stability and implant diameter, implant length, and localization (mandibular vs. maxillary). An increase in implant stability between insertion and exposure is significantly correlated with healing time and is higher for maxillary implants. These predictive factors should be further evaluated in prospective cohort studies to develop future preoperative risk-stratification models.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Dental Radiography and Imaging · Orthodontics and Dentofacial Orthopedics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Prof. Dr. Dr. Stoll & Partner, 79098 Freiburg, Germany
Department of Orthopedics and Trauma Surgery, Medical Centre, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, 79106 Freiburg, Germany
Institute of Medical Biometry and Statistics, Faculty of Medicine and Medical Center, University of Freiburg, 79104 Freiburg, Germany
References (72)
Show source-provided references
1. Implant stability measurements using resonance frequency analysis: Biological and biomechanical aspects and clinical implications10.1111/j.1600-0757.2008.00267.x ↗
2. Biological factors contributing to failures of osseointegrated oral implants, (I). Success criteria and epidemiology10.1046/j.0909-8836..t01-2-.x ↗
3. Significance of primary stability for osseointegration of dental implants10.1111/j.1600-0501.2005.01201.x ↗
4. The role of primary stability for successful immediate loading of dental implants. A literature review10.1016/j.jdent.2010.05.013 ↗
5. Assessment of implant stability as a prognostic determinant
6. Marginal bone loss around oral implants supporting fixed versus removable prostheses: A systematic review10.1186/s40729-020-00217-7 ↗
7. Methods used to assess implant stability: Current status
8. Early wound healing around endosseous implants: A review of the literature
9. Assessment of Implant Stability: Methods and Recent Advances10.9734/BJMMR/2016/21877 ↗
10. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis10.1034/j.1600-0501.1996.070308.x ↗
11. The relationship between resonance frequency analysis (RFA) and lateral displacement of dental implants: An in vitro study10.1111/joor.12024 ↗
12. Implant stability quotient (ISQ) vs. direct in vitro measurement of primary stability (micromotion): Effect of bone density and insertion torque
13. Resonance frequency analysis: Measuring implant stability and osseointegration
14. Factors Influencing Resonance Frequency Analysis (RFA) Measurements and 5-Year Survival of Neoss Dental Implants10.1155/2019/3209872 ↗
15. Diagnosis of implant stability and its impact on implant survival: A prospective case series study10.1111/j.1600-0501.2009.01820.x ↗
16. Reconstruction of the atrophic edentulous maxilla with free iliac crest grafts and implants: A 3-year report of a prospective clinical study10.1111/j.1708-8208.2007.00034.x ↗
17. Turkyilmaz, I., and McGlumphy, E.A. (2008). Influence of bone density on implant stability parameters and implant success: A retrospective clinical study. BMC Oral Health, 8.10.1186/1472-6831-8-32 ↗
18. [The Tübingen immediate implant in clinical studies]
19. Immediate Implant Placement: Positives and Negatives10.1097/ID.0b013e3181d47eaf ↗
20. Immediate implant placement into extraction sites: Surgical and restorative advantages
21. The ways and wherefores of immediate placement of implants into fresh extraction sites: A literature review10.1902/jop.1997.68.10.915 ↗
22. The effectiveness of immediate implant placement for single tooth replacement compared to delayed implant placement: A systematic review and meta-analysis10.1111/jcpe.13054 ↗
23. A 4-Year Retrospective Radiographic Study of Marginal Bone Loss of 156 Titanium Implants Placed with Ultrasonic Site Preparation10.11607/prd.3219 ↗
24. Clinical and radiographic evaluation of NobelActive TM dental implants10.1111/j.1600-0501.2011.02313.x ↗
25. Clinical Evaluation of Marginal Bone Loss and Stability in Two Types of Submerged Dental Implants10.11607/jomi.3087 ↗
26. Impact of mini-implant length on stability at the initial healing period: A controlled clinical study10.1186/1746-160X-9-30 ↗
27. Conventional SLA and chemically modified SLA implants in patients with poorly controlled type 2 Diabetes mellitus—A randomized controlled trial10.1111/j.1600-0501.2011.02369.x ↗
28. A bisphosphonate-coating improves the fixation of metal implants in human bone. A randomized trial of dental implants10.1016/j.bone.2012.02.001 ↗
29. Stability, marginal bone loss and survival of standard and modified sand-blasted, acid-etched implants in bilateral edentulous spaces: A prospective 15-month evaluation: 15-month prospective evaluation of SLA and modSLA implants10.1111/j.1600-0501.2010.02065.x ↗
30. Short (6-mm) dental implants versus sinus floor elevation and placement of longer (≥10-mm) dental implants: A randomized controlled trial with a 3-year follow-up10.1111/clr.12923 ↗
31. Development of a new implant primary stability parameter: Insertion torque revisited10.1111/j.1708-8208.2011.00392.x ↗
32. Resonance Frequency Analysis of Sinus Augmentation by Osteotome Sinus Floor Elevation and Lateral Window Technique10.1016/j.joms.2015.04.020 ↗
33. Factors Affecting Dental Implant Stability Measured Using the Ostell Mentor Device: A Systematic Review10.1097/ID.0000000000000308 ↗
34. Relation between bone density and primary implant stability
35. Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test10.5051/jpis.2013.43.1.30 ↗
36. The tissue renin-angiotensin system (tRAS) and the impact of its inhibition on inflammation and bone loss in the periodontal tissue10.22203/eCM.v040a13 ↗
37. Evaluation of dental implant stability in bone phantoms: Comparison between a quantitative ultrasound technique and resonance frequency analysis10.1111/cid.12622 ↗
38. Does the Time of Osseointegration in the Maxilla and Mandible Differ?10.1097/SCS.0000000000001067 ↗
39. Esposito, M., Grusovin, M.G., Polyzos, I.P., Felice, P., and Worthington, H.V. (2010). Interventions for replacing missing teeth: Dental implants in fresh extraction sockets (immediate, immediate-delayed and delayed implants). Cochrane Database of Syst. Rev.10.1002/14651858.CD005968.pub3 ↗
40. Loading of Titanium Implants With Hydrophilic Endosteal Surface 3 Weeks After Insertion: Clinical and Radiological Outcome of a 12-Month Prospective Clinical Trial10.1016/j.joms.2014.04.016 ↗
41. Immediate loading for implant restoration compared with early or conventional loading: A meta-analysis10.1016/j.jcms.2016.05.002 ↗
42. Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation10.1111/j.1600-0501.2007.01336.x ↗
43. Predicting osseointegration by means of implant primary stability. A resonance-frequency analysis study with delayed and immediately loaded ITI SLA implants10.1111/j.1600-0501.2004.01059.x ↗
44. Effect of Location on Primary Stability and Healing of Dental Implants10.1097/ID.0000000000000019 ↗
45. Measurement of Primary and Secondary Stability of Dental Implants by Resonance Frequency Analysis Method in Mandible10.1155/2013/506968 ↗
46. The influence of early loading on bony crest height and stability: A pilot study
47. Dental implants inserted in fresh extraction sockets versus healed sites: A systematic review and meta-analysis10.1016/j.jdent.2014.11.007 ↗
48. Resonance frequency analysis measurements of implants at placement surgery
49. Dental Implants in an Aged Population: Evaluation of Periodontal Health, Bone Loss, Implant Survival, and Quality of Life: Dental Implants in Aged Population10.1111/cid.12340 ↗
50. Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: Comparison of both techniques in a clinical trial
51. Dental implant failure rates and associated risk factors
52. Does Length, Diameter, or Bone Quality Affect Primary and Secondary Stability in Self-Tapping Dental Implants?10.1016/j.joms.2016.03.011 ↗
53. A comparative study of the effectiveness of early and delayed loading of short tissue-level dental implants with hydrophilic surfaces placed in the posterior section of the mandible—A preliminary study10.1016/j.aanat.2017.02.009 ↗
54. Relationship of implant stability and bone density derived from computerized tomography images10.1111/cid.12579 ↗
55. Influence of cortical bone thickness and implant length on implant stability at the time of surgery—clinical, prospective, biomechanical, and imaging study10.1016/j.bone.2005.06.019 ↗
56. Effects on primary stability of three different techniques for implant site preparation in synthetic bone models of different densities10.1016/j.bjoms.2016.07.004 ↗
57. Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone: What influences primary stability in cancellous bone10.1111/j.1365-2842.2010.02117.x ↗
58. The effect of implant length and diameter on the primary stability in different bone types
59. Marginal bone level changes in association with different vertical implant positions: A 3-year retrospective study10.5051/jpis.2017.47.4.231 ↗
60. Retrospective clinical study of ultrawide implants more than 6 mm in diameter10.1186/s40902-016-0075-z ↗
61. A Newly Designed Resonance Frequency Analysis Device for Dental Implant Stability Detection10.4012/dmj.26.665 ↗
62. Assessment of the Correlation Between Implant Stability and Bone Density by Computed Tomography and Resonance Frequency Analysis in Fresh Cadavers10.11607/jomi.2607 ↗
63. Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model
64. Resonance Frequency Analysis of One- Stage Dental Implant Stability During the Osseointegration Period10.1902/jop.2005.76.7.1066 ↗
65. Zanetti, E.M., Pascoletti, G., Calì, M., Bignardi, C., and Franceschini, G. (2018). Clinical Assessment of Dental Implant Stability During Follow-Up: What Is Actually Measured, and Perspectives. Biosensors, 8.10.3390/bios8030068 ↗
66. Validity and clinical significance of biomechanical testing of implant/bone interface10.1111/j.1600-0501.2006.01365.x ↗
67. Osstell Resonance Frequency Measurement Values as a Prognostic Factor in Implant Dentistry10.1563/AAID-JOI-D-13-00172 ↗
68. Reosseointegration of mechanically disintegrated implants in dogs: Mechanical and histometric analyses10.1111/clr.12135 ↗
69. Early detection of implant healing process using resonance frequency analysis10.1034/j.1600-0501.2003.00818.x ↗
70. Effects of anodized oxidation or turned implants on bone healing after using conventional drilling or trabecular compaction technique: Histomorphometric analysis and RFA10.1111/j.1600-0501.2006.01285.x ↗
71. Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value10.4047/jap.2011.3.1.10 ↗
72. Implant stability and bone density: Assessment of correlation in fresh cadavers using conventional and osteotome implant sockets10.1111/j.1600-0501.2009.01758.x ↗