Comparison of CAD/CAM and Conventional Denture Base Resins: A Systematic Review
Source abstract
Abstract
At present, complete dentures (CDs) remain the only treatment available for the majority of edentulous patients. CDs are primarily fabricated using a conventional method using polymethylmethacrylate (PMMA) resin. The steps involved in PMMA polymerisation directly affect the quality of the resin prosthetic base and any error reduces retention and occlusal accuracy of CDs. Furthermore, when using the conventional technique, the residual monomer alters the resin mechanical properties and may cause mucosal reactions. Recently, computer aided design and computer aided manufacture (CAD/CAM) techniques were increasingly used to fabricate CDs by machining resin discs that have been manufactured under high pressure and temperature. This systematic review compares CAD/CAM and conventional CDs according to their mechanical, physical and chemical characteristics, as well as the clinical impact of any differences between them. A review was conducted according to the preferred reporting items for systematic reviews and meta-analyses checklist on 392 publications from both PubMed and backward research. Fifteen studies have been included. Results showed that CAD/CAM resins had globally better physical and mechanical properties than conventional resins. The use of machined resin could improve the clinical performance, maintenance and longevity of CDs. Further studies in clinical use would be required to complement these results.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Dental Research and COVID-19
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
UFR d’Odontologie, Université Clermont Auvergne, CROC, F-63000 Clermont-Ferrand, France
CHU Clermont-Ferrand, Service d’Odontologie, F-63003 Clermont-Ferrand, France
References (54)
Show source-provided references
1. Dimensional Changes of Acrylic Resin Denture Bases: Conventional versus Injection-Molding Technique
2. Resin Denture Bases: Review of Accuracy and Methods of Polymerization
3. Dimensional Change in Complete Dentures Fabricated by Injection Molding and Microwave Processing10.1067/mpr.2003.3 ↗
4. Evaluation of the Level of Residual Monomer in Acrylic Denture Base Materials Having Different Polymerization Properties10.1111/j.1365-2842.1991.tb01684.x ↗
5. The Level of Residual Monomer in Injection Molded Denture Base Materials
6. An Update on Computer-Engineered Complete Dentures: A Systematic Review on Clinical Outcomes10.1016/j.prosdent.2016.08.017 ↗
7. Evaluation of Currently Available CAD/CAM Denture Systems10.11607/ijp.5031 ↗
8. CAD/CAM Complete Dentures: A Review of Two Commercial Fabrication Systems
9. A Comparison of Two Digital Techniques for the Fabrication of Complete Removable Dental Prostheses: A Pilot Clinical Study10.1016/j.prosdent.2016.03.022 ↗
10. CAD-CAM Milled versus Rapidly Prototyped (3D-Printed) Complete Dentures: An in Vitro Evaluation of Trueness10.1016/j.prosdent.2018.09.001 ↗
11. A 3D Printing Replication Technique for Fabricating Digital Dentures10.1016/j.prosdent.2019.08.026 ↗
12. A Review of Computer-Aided Design/Computer-Aided Manufacture Techniques for Removable Denture Fabrication10.4103/1305-7456.178304 ↗
13. Advantages of CAD/CAM versus Conventional Complete Dentures-A Review10.3889/oamjms.2018.308 ↗
14. Do CAD/CAM Dentures Really Release Less Monomer than Conventional Dentures?10.1007/s00784-016-1961-6 ↗
15. Computer-Aided Technology for Fabricating Complete Dentures: Systematic Review of Historical Background, Current Status, and Future Perspectives10.1016/S0022-3913(13)60318-2 ↗
16. Fabricating Complete Dentures with CAD/CAM Technology10.1016/j.prosdent.2013.10.014 ↗
17. Clinical Performance of CAD-CAM-Fabricated Complete Dentures: A Cross-Sectional Study10.1016/j.prosdent.2016.03.017 ↗
18. CAD/CAM Fabricated Complete Dentures: Concepts and Clinical Methods of Obtaining Required Morphological Data10.1016/S0022-3913(12)60015-8 ↗
19. Wang, C., Shi, Y.-F., Xie, P.-J., and Wu, J.-H. (2021). Accuracy of Digital Complete Dentures: A Systematic Review of in Vitro Studies. J. Prosthet. Dent.10.1016/j.prosdent.2020.01.004 ↗
20. CAD/CAM Complete Denture Systems and Physical Properties: A Review of the Literature10.1111/jopr.13243 ↗
21. The Residual Monomer Content and Mechanical Properties of CAD\CAM Resins Used in the Fabrication of Complete Dentures as Compared to Heat Cured Resins10.19082/4766 ↗
22. A Comparison of the Surface Properties of CAD/CAM and Conventional Polymethylmethacrylate (PMMA)10.1111/jopr.13033 ↗
23. Comparison of Mechanical Properties of 3D-Printed, CAD/CAM, and Conventional Denture Base Materials10.1111/jopr.13175 ↗
24. CAD/CAM Milled Complete Removable Dental Prostheses: An in Vitro Evaluation of Biocompatibility, Mechanical Properties, and Surface Roughness10.4012/dmj.2017-207 ↗
25. Mechanical Properties of CAD/CAM Denture Base Resins10.11607/ijp.6025 ↗
26. Influence of High-Pressure Polymerization on Mechanical Properties of Denture Base Resins10.1111/jopr.13231 ↗
27. Assessment of CAD-CAM Polymers for Digitally Fabricated Complete Dentures10.1016/j.prosdent.2019.12.008 ↗
28. Adherence of Candida to Complete Denture Surfaces in Vitro: A Comparison of Conventional and CAD/CAM Complete Dentures10.4047/jap.2017.9.5.402 ↗
29. Steinmassl, O., Offermanns, V., Stöckl, W., Dumfahrt, H., Grunert, I., and Steinmassl, P.-A. (2018). In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins. Mater. Basel Switz., 11.10.3390/ma11030401 ↗
30. Influence of CAD/CAM Fabrication on Denture Surface Properties10.1111/joor.12621 ↗
31. Evaluation of Flexural Strength and Surface Properties of Prepolymerized CAD/CAM PMMA-Based Polymers Used for Digital 3D Complete Dentures
32. In Vitro Evaluation of Adhesion of Candida Albicans on CAD/CAM PMMA-Based Polymers10.1111/jopr.12942 ↗
33. Flexural Strength of Denture Base Acrylic Resins Processed by Conventional and CAD-CAM Methods10.1016/j.prosdent.2019.03.010 ↗
34. A Comparison of the Flexural and Impact Strengths and Flexural Modulus of CAD/CAM and Conventional Heat-Cured Polymethyl Methacrylate (PMMA)10.1111/jopr.12926 ↗
35. Effects of Denture Adhesive on the Retention of Milled and Heat-Activated Maxillary Denture Bases: A Clinical Study10.1016/j.prosdent.2017.10.013 ↗
36. Complete Denture Wearing and Fractures among Edentulous Patients Treated in University Clinics10.1111/j.1741-2358.2011.00551.x ↗
37. Effect of High-Pressure Polymerization on Mechanical Properties of PMMA Denture Base Resin10.1016/j.jmbbm.2012.12.011 ↗
38. Biting and Chewing in Overdentures, Full Dentures, and Natural Dentitions10.1177/00220345000790071501 ↗
39. Risk Factors Associated with Denture Stomatitis in the United States10.1111/j.1600-0714.2005.00287.x ↗
40. Mixed Candida Albicans and Candida Glabrata Populations Associated with the Pathogenesis of Denture Stomatitis10.1111/j.1399-302X.2008.00439.x ↗
41. Candida Albicans Importance to Denture Wearers. A Literature Review
42. Adherence of Candida Albicans to Denture-Base Materials with Different Surface Finishes10.1016/S0300-5712(97)00034-1 ↗
43. Influence of Surface Free Energy of Denture Base and Liner Materials on Candida Albicans Biofilms10.1111/jicd.12079 ↗
44. An Evaluation of the Adherence of Candida Albicans on the Surface of Heat Cure Denture Base Material Subjected to Different Stages of Polishing
45. In Vitro Candida Colonization on Acrylic Resins and Denture Liners: Influence of Surface Free Energy, Roughness, Saliva, and Adhering Bacteria
46. Effects of Polishing Techniques on the Surface Roughness of Acrylic Denture Base Resins10.1016/j.prosdent.2004.10.002 ↗
47. Comparison of Surface Roughness of Oral Hard Materials to the Threshold Surface Roughness for Bacterial Plaque Retention: A Review of the Literature10.1016/S0109-5641(97)80038-3 ↗
48. An in Vitro Study into the Effect of a Limited Range of Denture Cleaners on Surface Roughness and Removal of Candida Albicans from Conventional Heat-Cured Acrylic Resin Denture Base Material10.1111/j.1365-2842.2004.01250.x ↗
49. Biofilm Formation and Candida Albicans Morphology on the Surface of Denture Base Materials10.1111/myc.12420 ↗
50. Polymerization Cycles on Hardness and Surface Gloss of Denture Bases
51. Evaluation of Vickers Hardness of Different Types of Acrylic Denture Base Resins with and without Glass Fibre Reinforcement10.1111/j.1741-2358.2010.00435.x ↗
52. Hardness of Denture Base and Hard Chair-Side Reline Acrylic Resins10.1590/S1678-77572005000300017 ↗
53. Minimization of the Inevitable Residual Monomer in Denture Base Acrylic10.1016/j.dental.2005.03.003 ↗
54. International Organization for Standardization (2013). Dentistry-Base Polymers Part I: Denture Base Polymers, ISO. ISO 20795-1.