journal article·2021-10-30Open access

Robustness of PET Radiomics Features: Impact of Co-Registration with MRI

Alessandro Stefano, Antonio Leal, Selene Richiusa, Phan Trang, Albert Comelli, Viviana Benfante, Sebastiano Cosentino, Maria G. Sabini, Antonino Tuttolomondo, Roberto Altieri, Francesco Certo, Giuseppe Maria Vincenzo Barbagallo, Massimo Ippolito, Giorgio Russo

Applied Sciences· Volume 11· Issue 21

Abstract

Radiomics holds great promise in the field of cancer management. However, the clinical application of radiomics has been hampered by uncertainty about the robustness of the features extracted from the images. Previous studies have reported that radiomics features are sensitive to changes in voxel size resampling and interpolation, image perturbation, or slice thickness. This study aims to observe the variability of positron emission tomography (PET) radiomics features under the impact of co-registration with magnetic resonance imaging (MRI) using the difference percentage coefficient, and the Spearman’s correlation coefficient for three groups of images: (i) original PET, (ii) PET after co-registration with T1-weighted MRI and (iii) PET after co-registration with FLAIR MRI. Specifically, seventeen patients with brain cancers undergoing [11C]-Methionine PET were considered. Successively, PET images were co-registered with MRI sequences and 107 features were extracted for each mentioned group of images. The variability analysis revealed that shape features, first-order features and two subgroups of higher-order features possessed a good robustness, unlike the remaining groups of features, which showed large differences in the difference percentage coefficient. Furthermore, using the Spearman’s correlation coefficient, approximately 40% of the selected features differed from the three mentioned groups of images. This is an important consideration for users conducting radiomics studies with image co-registration constraints to avoid errors in cancer diagnosis, prognosis, and clinical outcome prediction.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiomics and Machine Learning in Medical Imaging · Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute of Molecular Bioimaging and Physiology, National Research Council (IBFM-CNR), 90015 Cefalù, Italy

Departamento de Fisiología Médica y Biofísica, University de Seville/Instituto de Biomedicina de Sevilla (IBiS), 41013 Seville, Spain

Department of Physics and Astronomy “E. Majorana”, University of Catania, 95124 Catania, Italy

Ri.Med Foundation, Via Bandiera 11, 90133 Palermo, Italy

Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Molecular and Clinical Medicine, University of Palermo, 90127 Palermo, Italy

Nuclear Medicine Department, Cannizzaro Hospital, 95126 Catania, Italy

Neurosurgical Unit, AOU Policlinico “G. Rodolico-San Marco”, University of Catania, 95123 Catania, Italy

Interdisciplinary Research Center on Diagnosis and Management of Brain Tumors, University of Catania, 95123 Catania, Italy

References (35)

Show source-provided references
1. Radiomics in PET/CT: More Than Meets the Eye?10.2967/jnumed.116.184655 ↗
2. Radiomics: Is it time to compose the puzzle?10.1007/s40336-018-0302-y ↗
3. CT radiomics can help screen the Coronavirus disease 2019 (COVID-19): A preliminary study10.1007/s11432-020-2849-3 ↗
4. Stefano, A., Gioè, M., Russo, G., Palmucci, S., Torrisi, S.E., Bignardi, S., Basile, A., Comelli, A., Benfante, V., and Sambataro, G. (2020). Performance of radiomics features in the quantification of idiopathic pulmonary fibrosis from HRCT. Diagnostics, 10.10.3390/diagnostics10050306 ↗
5. Stefano, A., Comelli, A., Bravatà, V., Barone, S., Daskalovski, I., Savoca, G., Sabini, M.G., Ippolito, M., and Russo, G. (2020). A preliminary PET radiomics study of brain metastases using a fully automatic segmentation method. BMC Bioinform., 21.10.1186/s12859-020-03647-7 ↗
6. Alongi, P., Laudicella, R., Stefano, A., Caobelli, F., Comelli, A., Vento, A., Sardina, D., Ganduscio, G., Toia, P., and Ceci, F. (2020). Choline PET/CT features to predict survival outcome in high risk prostate cancer restaging: A preliminary machine-learning radiomics study. Q. J. Nucl. Med. Mol. Imaging, Online ahead of print.
7. Comelli, A., Stefano, A., Coronnello, C., Russo, G., Vernuccio, F., Cannella, R., Salvaggio, G., Lagalla, R., and Barone, S. (2020). Radiomics: A New Biomedical Workflow to Create a Predictive Model. Annual Conference on Medical Image Understanding and Analysis, Springer.10.1007/978-3-030-52791-4_22 ↗
8. Machine learning applications in prostate cancer magnetic resonance imaging10.1186/s41747-019-0109-2 ↗
9. Robustness of radiomic features in magnetic resonance imaging: Review and a phantom study10.1186/s42492-019-0025-6 ↗
10. Impact of image preprocessing methods on reproducibility of radiomic features in multimodal magnetic resonance imaging in glioblastoma10.1002/acm2.12795 ↗
11. Radiomics in Glioblastoma: Current Status and Challenges Facing Clinical Implementation10.3389/fonc.2019.00374 ↗
12. AI-based applications in hybrid imaging: How to build smart and truly multi-parametric decision models for radiomics10.1007/s00259-019-04414-4 ↗
13. Radiomics for precision medicine: Current challenges, future prospects, and the proposal of a new framework10.1016/j.ymeth.2020.05.022 ↗
14. Predictive and Prognostic Value of Early Disease Progression by PET Evaluation in Advanced Non-Small Cell Lung Cancer10.1159/000448005 ↗
15. Reproducibility of Tumor Uptake Heterogeneity Characterization Through Textural Feature Analysis in 18 F-FDG PET10.2967/jnumed.111.099127 ↗
16. Robustness of intratumour 18F-FDG PET uptake heterogeneity quantification for therapy response prediction in oesophageal carcinoma10.1007/s00259-013-2486-8 ↗
17. Chou, K.-T., Latifi, K., Moros, E.G., Feygelman, V., Huang, T.-C., Dilling, T.J., Perez, B., and Zhang, G.G. (2018, January 19–21). Evaluation of Radiomic Features Stability When Deformable Image Registration Is Applied. Proceedings of the International Joint Conference on Biomedical Engineering Systems and Technologies, Funchal, Portugal.10.5220/0006694301530158 ↗
18. 18F-FDG-PET-based radiomics features to distinguish primary central nervous system lymphoma from glioblastoma10.1016/j.nicl.2019.101912 ↗
19. Radiomics signature based on FDG-PET predicts proliferative activity in primary glioma10.1016/j.crad.2019.06.019 ↗
20. Tissue Classification to Support Local Active Delineation of Brain Tumors10.1007/978-3-030-39343-4_1 ↗
21. A Graph-Based Method for PET Image Segmentation in Radiotherapy Planning: A Pilot Study
22. 11C-methionine-PET for differentiating recurrent brain tumor from radiation necrosis: Radiomics approach with random forest classifier10.1038/s41598-019-52279-2 ↗
23. Glioma Survival Prediction with Combined Analysis of In Vivo 11C-MET PET Features, Ex Vivo Features, and Patient Features by Supervised Machine Learning10.2967/jnumed.117.202267 ↗
24. Challenges and Promises of PET Radiomics10.1016/j.ijrobp.2017.12.268 ↗
25. Hybrid descriptive-inferential method for key feature selection in prostate cancer radiomics10.1002/asmb.2642 ↗
26. A Fully Automated Segmentation System of Positron Emission Tomography Studies10.1007/978-3-030-39343-4_30 ↗
27. Radiomics analysis of 18F-Choline PET/CT in the prediction of disease outcome in high-risk prostate cancer: An explorative study on machine learning feature classification in 94 patients10.1007/s00330-020-07617-8 ↗
28. Lifex: A freeware for radiomic feature calculation in multimodality imaging to accelerate advances in the characterization of tumor heterogeneity10.1158/0008-5472.CAN-18-0125 ↗
29. A fully automatic method for biological target volume segmentation of brain metastases10.1002/ima.22154 ↗
30. Reliability and prognostic value of radiomic features are highly dependent on choice of feature extraction platform10.1007/s00330-020-06957-9 ↗
31. Computational radiomics system to decode the radiographic phenotype10.1158/0008-5472.CAN-17-0339 ↗
32. User’s guide to correlation coefficients10.1016/j.tjem.2018.08.001 ↗
33. Meijer, K.M. (2019). Accuracy and Stability of Radiomic Features for Characterising Tumour Heterogeneity Using Multimodality Imaging: A Phantom Study. [Master’s Thesis, University of Twente].
34. Radiomics feature robustness as measured using an MRI phantom
35. EANM/EARL FDG-PET/CT accreditation-summary results from the first 200 accredited imaging systems10.1007/s00259-017-3853-7 ↗