In this study, the music-inspired Harmony Search (HS) algorithm is modified for the optimization of active tuned mass dampers (ATMDs). The modification of HS includes the consideration of the best solution with a defined probability and updating of algorithm parameters such as harmony memory, considering rate and pitch adjusting rate. The design variables include all the mechanical properties of ATMD, such as the mass, stiffness and damping coefficient, and the active controller parameters of the proposed proportional–integral–derivative (PID) type controllers. In the optimization process, the analysis of an ATMD implemented structure is done using the generated Matlab Simulink block diagram. The PID controllers were optimized for velocity feedback control, and the objective of the optimization is the minimization of the top story displacement by using the limitation of the stroke capacity of ATMD. The optimum results are presented for different cases of the stroke capacity limit of ATMD. According to the results, the method is effective in reducing the maximum displacement of the structure by 53.71%, while a passive TMD can only reduce it by 31.22%.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Vibration Control and Rheological Fluids · Structural Engineering and Vibration Analysis · Hydraulic and Pneumatic Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil Engineering, Istanbul University – Cerrahpaşa, 34310 Istanbul, Turkey

College of IT Convergence, Gachon University, Seongnam 13120, Korea

Funding

National Research Foundation of Korea

References (41)

Show source-provided references
1. Miyamoto, H.K., Gilani, A.S.J., and Gündoğdu, Y.Z. (June, January 30). Innovative Seismic Retrofit of An Iconic Building. Proceedings of the 7th National Conference on Earthquake Engineering, Istanbul, Turkey.
2. Tuned mass dampers10.1007/s11831-013-9091-7 ↗
3. Estimating optimum parameters of tuned mass dampers using harmony search10.1016/j.engstruct.2011.05.024 ↗
4. Simple ATMD control methodology for tall buildings subject to wind loads10.1061/(ASCE)0733-9445(1996)122:1(83) ↗
5. Critical mode control of a wind-loaded tall building using an active tuned mass damper10.1016/S0141-0296(97)00172-7 ↗
6. Optimal damper characteristics of ATMD for buildings under wind loads10.1061/(ASCE)0733-9445(1999)125:12(1376) ↗
7. A reduced-order modeling technique for tall buildings with active tuned mass damper10.1002/eqe.10 ↗
8. Performance of a five-storey benchmark model using an active tuned mass damper and a fuzzy controller10.1016/S0141-0296(03)00132-9 ↗
9. Active control of cross wind response of 76-story tall building using a fuzzy controller10.1061/(ASCE)0733-9399(2004)130:4(492) ↗
10. Evaluation of the lever-type active tuned mass damper for structures10.1002/stc.42 ↗
11. Seismic response of controlled structures with active multiple tuned mass dampers10.1007/s11803-006-0657-3 ↗
12. Active control of high rise building structures using fuzzy logic and genetic algorithms10.1016/j.engstruct.2006.04.015 ↗
13. Estimation of active multiple tuned mass dampers for asymmetric structures10.12989/sem.2008.29.5.505 ↗
14. Vibration control of a structure with ATMD against earthquake using fuzzy logic controllers10.1016/j.jsv.2008.03.058 ↗
15. Seismic-vibration mitigation of a nonlinear structural system with an ATMD through a fuzzy PID controller10.1007/s11071-009-9500-5 ↗
16. Self-tuning fuzzy logic control of a non-linear structural system with ATMD against earthquake10.1007/s11071-008-9392-9 ↗
17. An optimum design methodology of active tuned mass damper for asymmetric structures10.1016/j.ymssp.2009.09.011 ↗
18. Effectiveness of active multiple-tuned mass dampers for asymmetric structures considering soil–structure interaction effects10.1002/tal.624 ↗
19. Active tuned mass damper control of wind turbine nacelle/tower vibrations with damaged foundations10.4028/www.scientific.net/KEM.569-570.660 ↗
20. Wavelet PSO-based LQR algorithm for optimal structural control using active tuned mass dampers10.1111/mice.12017 ↗
21. You, K.P., You, J.Y., and Kim, Y.M. (2014). LQG control of along-wind response of a tall building with an ATMD. Math. Probl. Eng.10.1155/2014/206786 ↗
22. Minimizing structural vibrations with absorbers10.1002/eqe.4290080303 ↗
23. Vibration control of buildings using ATMD against earthquake excitations through interval type-2 fuzzy logic controller
24. Vibration control using ATMD and site measurements on the Shanghai World Financial Center Tower10.1002/tal.1027 ↗
25. Seismic control response of structures using an ATMD with fuzzy logic controller and PSO method10.12989/sem.2014.51.4.547 ↗
26. Adaptive fuzzy controller for active tuned mass damper of a benchmark tall building subjected to seismic and wind loads10.1002/tal.1091 ↗
27. Hybrid active tuned mass dampers for structures under the ground acceleration10.1002/stc.1716 ↗
28. Enhanced hybrid active tuned mass dampers for structures10.1002/stc.2067 ↗
29. A hybrid LQR-PID control design for seismic control of buildings equipped with ATMD10.1007/s11709-016-0382-6 ↗
30. (2010). MATLAB, The MathWorks Inc. version 7.10.0 (R2010a).
31. Design strategies of viscous dampers for seismic protection of building structures: A review10.1016/j.soildyn.2018.12.024 ↗
32. Optimum design of tuned mass dampers by displacement and energy perspectives10.1016/j.soildyn.2013.02.013 ↗
33. Earthquake-resilient design of base isolated buildings with TMD at basement: Application to a case study10.1016/j.soildyn.2018.06.022 ↗
34. Multi-objective evolutionary seismic design with passive energy dissipation systems10.1080/13632460802598545 ↗
35. A new heuristic optimization algorithm: Harmony search10.1177/003754970107600201 ↗
36. Tuned mass dampers for response control of torsional buildings10.1002/eqe.119 ↗
37. (2009). Quantification of Building Seismic Performance Factors, Technical Report No. FEMA P-695.
38. Evaluation and analytical approximation of Tuned Mass Damper performance in an earthquake environment10.12989/sss.2012.10.2.155 ↗
39. Earthquake protection of structures with nonlinear viscous dampers optimized through an energy-based stochastic approach10.1016/j.engstruct.2018.09.076 ↗
40. Optimal design of tuned liquid column dampers for seismic response control of base-isolated structures10.1007/s00707-017-1980-7 ↗
41. Optimal design and seismic performance of tuned fluid inerter applied to structures with friction pendulum isolators10.1016/j.soildyn.2020.106099 ↗