Electrochemical Sensors for Monitoring the Corrosion Conditions of Reinforced Concrete Structures: A Review
Source abstract
Abstract
Several methods for corrosion monitoring of reinforced concrete structures (RCS) have been proposed in the last few decades. These systems may be used either in new, existing or repaired structures. The corrosion monitoring can be performed by different methodologies. These may or may not be destructive, use different degrees of complexity and cost, and provide information on the progression and kinetics of the corrosion phenomena. The destructive methods are limited to sampling. Therefore, these may not be representative of the whole structure, which is extremely important in RCS with large heterogeneities both in terms of materials used and in terms of the exposure environment. Within this context, non-destructive methods have been widely developed, which are intended to provide quick information about the entire structure. Ideally, these systems should be able to detect the corrosion state of the steel inside the concrete, the main causes of corrosion and the evolution of corrosion phenomena over time. This manuscript reviews and summarizes the actual state of the art and the main achievements in the field of electrochemical sensors based on non-destructive methods for corrosion monitoring of RCS in the last few years. The challenges and perspectives in this field will also be discussed.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Concrete Corrosion and Durability · Smart Materials for Construction · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Engiprojects, Lda, Rua Mestre Lima de Freitas 9B, 1500-895 Lisbon, Portugal
References (100+)
Show source-provided references
1. Reinforcement corrosion in concrete structures, its monitoring and service life prediction––A review10.1016/S0958-9465(02)00086-0 ↗
2. Böhni, H. (2005). Corrosion in Reinforced Concrete Structures, Elsevier.10.1533/9781845690434 ↗
3. Andrade, C. (2016). 14—Future trends in research on reinforcement corrosion A2—Poursaee, Amir. Corrosion of Steel in Concrete Structures, Woodhead Publishing.10.1016/B978-1-78242-381-2.00014-6 ↗
4. Aliofkhazraei, M. (2016). Chapter 5—Failure analysis of reinforced concrete structures subjected to chloride penetration and reinforcements corrosion A2—Makhlouf, Abdel Salam Hamdy. Handbook of Materials Failure Analysis with Case Studies from the Chemicals, Concrete and Power Industries, Butterworth-Heinemann.
5. Bertolini, L., Elsener, B., Pedeferri, P., Redaelli, E., and Polder, R.B. (2013). Corrosion of Steel in Concrete: Prevention, Diagnosis, Repair, John Wiley & Sons, Inc.. [2nd ed.].10.1002/9783527651696 ↗
6. Dhawan, S., Bhalla, S., and Bhattacharjee, B. (2014, January 1–6). Reinforcement Corrosion in Concrete Structures and Service Life Predictions—A Review. Proceedings of the 9th International Symposium on Advanced Science and Technology in Experimental Mechanics, New Delhi, India.
7. Steel corrosion and service life of reinforced concrete structures10.1080/15732470601155490 ↗
8. Parrott, L.J. (1987). A Review of Carbonation in Reinforced Concrete, Cement and Concrete Association.
9. Richardson, M.G. (2003). Fundamentals of Durable Reinforced Concrete, CRC Press.10.1201/9781482272109 ↗
10. Effect of carbonation on release of bound chlorides in chloride-contaminated concrete10.1680/jmacr.15.00234 ↗
11. Factors affecting threshold chloride for reinforcement corrosion in concrete10.1016/0008-8846(95)00148-6 ↗
12. The influence of surface finish of reinforcing steel and pH of the test solution on the chloride threshold concentration for corrosion initiation in synthetic pore solutions10.1016/0008-8846(96)00018-X ↗
13. Chloride threshold values to depassivate reinforcing bars embedded in a standardized OPC mortar10.1016/S0008-8846(00)00265-9 ↗
14. Chloride Corrosion Threshold of Reinforcing Steel in Alkaline Solutions—Open-Circuit Immersion Tests10.5006/1.3290325 ↗
15. Chloride threshold dependence of pitting potential of reinforcements10.1016/S0013-4686(02)00283-9 ↗
16. Chloride Corrosion Threshold of Reinforcing Steel in Alkaline Solutions—Cyclic Polarization Behavior10.5006/1.3287678 ↗
17. Potentiostatic determination of chloride threshold values for rebar depassivation: Experimental and statistical study10.1016/j.electacta.2004.01.034 ↗
18. Corrosion performance of conventional (ASTM A615) and low-alloy (ASTM A706) reinforcing bars embedded in concrete and exposed to chloride environments10.1016/j.cemconres.2004.06.004 ↗
19. Chloride threshold for rebar corrosion in concrete with addition of silica fume10.1016/j.corsci.2007.07.007 ↗
20. Initial corrosion presented by chloride threshold penetration of concrete up to 10 year-results under marine site10.1016/j.conbuildmat.2012.07.061 ↗
21. Influence of CaCl2 and NaCl from different sources on chloride threshold value for the corrosion of steel reinforcement in concrete10.1016/j.conbuildmat.2010.07.023 ↗
22. Silva, N. (2013). Chloride Induced Corrosion of Reinforcement Steel in Concrete: Threshold Values and Ion Distributions at the Concrete-Steel Interface, Chalmers University of Technology. Doktorsavhandlingar vid Chalmers Tekniska Högskola.
23. Influence of flexural fatigue on chloride threshold value for the corrosion of steels in Ca(OH)2 solutions10.1016/j.matchemphys.2015.08.016 ↗
24. The effect of carbonate and sulfate ions on chloride threshold level of reinforcement corrosion in mortar with/without fly ash10.1016/j.conbuildmat.2016.03.018 ↗
25. Chloride threshold value to initiate reinforcement corrosion in simulated concrete pore solutions: The influence of surface finishing and pH10.1016/j.conbuildmat.2017.03.004 ↗
26. A comprehensive probabilistic model of chloride ingress in unsaturated concrete10.1016/j.engstruct.2010.11.008 ↗
27. A probabilistic threshold for the onset of carbonation-induced corrosion10.1080/19648189.2013.791071 ↗
28. Reliability analysis of chloride penetration in saturated concrete10.1016/S0266-8920(02)00014-0 ↗
29. Accelerated carbonation tests for the probabilistic prediction of the durability of concrete structures10.1016/j.conbuildmat.2014.05.103 ↗
30. Experimental and probabilistic analysis of time to corrosion-induced cover cracking for marine reinforced concrete structures10.1080/1478422X.2016.1213082 ↗
31. Probabilistic models applied to safety assessment of reinforced concrete structures subjected to chloride ingress10.1016/j.engfailanal.2013.01.023 ↗
32. Probabilistic analysis of the time to chloride induced corrosion for different Self-Compacting Concretes10.1016/j.conbuildmat.2013.05.110 ↗
33. Probabilistic modeling of chloride-induced corrosion in concrete structures using first- and second-order reliability methods10.1016/j.cemconcomp.2012.05.001 ↗
34. Probabilistic evaluation of initiation time of chloride-induced corrosion10.1016/j.ress.2006.12.010 ↗
35. Probabilistic Corrosion Initiation Time Assessment of Existing Concrete Structures Under Marine Environment10.1007/s13369-015-1774-y ↗
36. Probabilistic durability assessment of concrete structures in marine environments: Reliability and sensitivity analysis10.1007/s13344-017-0008-3 ↗
37. Probabilistic analysis of reinforcement corrosion due to the combined action of carbonation and chloride ingress in concrete10.1016/j.conbuildmat.2016.07.120 ↗
38. Lifetime modeling of chloride-induced corrosion in concrete structures with Portland and blended cements10.1080/15732479.2015.1076487 ↗
39. Corrosion cracking prediction updating of deteriorating RC structures using inspection information10.1016/j.ress.2009.02.011 ↗
40. Spatial time-dependent reliability analysis of corrosion damage and the timing of first repair for RC structures10.1016/j.engstruct.2006.09.004 ↗
41. Modelling of the steel—Concrete interface to obtain information on reinforcement bar corrosion10.1007/s10800-004-8348-0 ↗
42. Modelling of interaction between corrosion-induced concrete cover crack and steel corrosion rate10.1016/j.corsci.2012.11.028 ↗
43. Theoretical considerations on the supposed linear relationship between concrete resistivity and corrosion rate of steel reinforcement10.1002/maco.200403841 ↗
44. Modelling steel corrosion in concrete structures10.1007/s11527-005-9022-7 ↗
45. Electrochemical frequency modulation and inductively coupled plasma atomic emission spectroscopy methods for monitoring corrosion rates and inhibition of low alloy steel corrosion in HCl solutions and a test for validity of the Tafel extrapolation method10.1016/j.corsci.2009.01.006 ↗
46. Corrosion rate monitoring in the laboratory and on-site10.1016/0950-0618(95)00044-5 ↗
47. Chloride induced reinforcement corrosion: Electrochemical monitoring of initiation stage and chloride threshold values10.1016/j.corsci.2011.01.025 ↗
48. Ervin, B.L. (2007). Monitoring Corrosion of Rebar Embedded in Mortar Using Guided Ultrasonic Waves, ProQuest.10.1117/12.714180 ↗
49. Monitoring of corrosion in reinforced concrete structure using Bragg grating sensing10.1016/j.ndteint.2010.11.011 ↗
50. Corrosion Monitoring of Reinforced Concrete Structures—A Review10.1016/S1452-3981(23)17049-0 ↗
51. Corrosion in Reinforced Concrete Panels: Wireless Monitoring and Wavelet-Based Analysis10.3390/s140203395 ↗
52. Embedded capacitor sensor for monitoring corrosion of reinforcement in concrete
53. Monitoring of steel corrosion in concrete by electrode arrays and electrical resistance probes10.1016/j.electacta.2007.06.060 ↗
54. Acoustic emission monitoring and damage mode discrimination of APS thermal barrier coatings under high temperature CMAS corrosion10.1016/j.surfcoat.2016.06.080 ↗
55. Non-destructive testing of concrete: A review of methods10.56748/ejse.141931 ↗
56. British Standards Institution (2001). Non-Destructive Testing: Visual Testing: General Principles, British Standards Institution.
57. Maierhofer, C., Reinhardt, H.-W., and Dobmann, G. (2010). Non-Destructive Evaluation of Reinforced Concrete Structures: Non-Destructive Testing Methods, Elsevier.10.1533/9781845699536 ↗
58. Destructive and Non-destructive Testing of Concrete Structures
59. Reinforced concrete structure: Non destructive in situ strength assessment of concrete10.1016/j.conbuildmat.2014.11.023 ↗
60. Non-Destructive Techniques Based on Eddy Current Testing10.3390/s110302525 ↗
61. Non-Destructive Evaluation for Corrosion Monitoring in Concrete: A Review and Capability of Acoustic Emission Technique10.3390/s150819069 ↗
62. (2017, August 22). 17/30351884 DC—BS EN 12390-10. Testing Hardened Concrete. Part 10. Determination of the Carbonation Resistance of Concrete at Atmospheric Levels of Carbon 17/30351884 DC—BS EN 12390-10. Testing Hardened Concrete. Part 10. Determination of the Carbonation Resistance of Concrete at Atmospheric Levels of Carbon Dioxide. Available online: https://shop.bsigroup.com/ProductDetail?pid=000000000030351884.
63. (2017, August 22). BS EN 14630:2006—Products and Systems for the Protection and Repair of Concrete Structures. Test Methods. Determination of Carbonation Depth in Hardened Concrete by the Phenolphthalein Method. Available online: https://shop.bsigroup.com/ProductDetail?pid=000000000030091526.
64. (2017, August 22). BS EN 12390-11:2015—Testing Hardened Concrete. Determination of the Chloride Resistance of Concrete, Unidirectional Diffusion. Available online: https://shop.bsigroup.com/ProductDetail/?pid=000000000030314030.
65. Raupach, M., Elsener, B., Polder, R., and Mietz, J. (2007). Corrosion of Reinforcement in Concrete: Mechanisms, Monitoring, Inhibitors and Rehabilitation Techniques, CRC Press.10.1533/9781845692285 ↗
66. Raupach, M. (2007). 24—Renovation of the cathodic protection system of a concrete bridge after 12 years of operation. Corrosion of Reinforcement in Concrete, Woodhead Publishing.10.1533/9781845692285 ↗
67. Monitoring System for the Corrosion Risk of Steel in Concrete Structures
68. Proposing new methods to appraise segregation resistance of self-consolidating concrete based on electrical resistivity10.1016/j.conbuildmat.2017.04.092 ↗
69. Corrosion of reinforcing steel evaluated by means of concrete resistivity measurements10.1016/S0010-938X(01)00033-6 ↗
70. Corrosion rate of steel in concrete—Measurements beyond the Tafel law10.1016/j.corsci.2005.06.021 ↗
71. Myrdal, R. (2014). The Electrochemistry and Characteristics of Embeddable Reference Electrodes for Concrete, Woodhead Publishing.
72. Sensor for oxygen evaluation in concrete10.1016/j.cemconcomp.2006.01.006 ↗
73. Sensor systems for use in reinforced concrete structures10.1016/j.conbuildmat.2004.03.008 ↗
74. Aspects of the electrochemistry of steel in concrete10.1038/297109a0 ↗
75. Monitoring of the degradation of concrete structures in environments containing chloride ions10.1016/j.conbuildmat.2013.05.042 ↗
76. Bergmeister, K., and Santa, U. (2000). Structural Health Monitoring of Concrete Bridges. Interferometry in Speckle Light, Springer.10.1007/978-3-642-57323-1_79 ↗
77. Gro Markeset, V.O. (2008). Critical Chloride Content in Reinforced Concrete COIN Workshop, 5–6 June 2008, Trondheim, Norway, Institute of Materials.
78. Development of an embeddable sensor to monitor the corrosion process of new and existing reinforced concrete structures10.1016/j.conbuildmat.2009.04.001 ↗
79. Long-term relative performance of embedded sensor and surface mounted electrode for corrosion monitoring of steel in concrete structures10.1016/j.snb.2013.10.123 ↗
80. Embedded Sensors for Corrosion Monitoring of Existing Reinforced Concrete Structures10.4028/www.scientific.net/MSF.587-588.677 ↗
81. Chaker, V. (1986). The Determination of the Corrosion Rate of Steel Embedded in Concrete by the Polarization Resistance and AC Impedance Methods. Corrosion Effect of Stary Currents and the Techniques for Evaluating Corrosion of Rebars in Concrete, ASTM International.
82. A Galvanic Sensor for Monitoring the Corrosion Condition of the Concrete Reinforcing Steel: Relationship between the Galvanic and the Corrosion Currents10.3390/s91108391 ↗
83. Non-substrate EIS monitoring of organic coatings with embedded electrodes10.1016/j.porgcoat.2009.10.001 ↗
84. Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method10.1007/BF02483292 ↗
85. Characterization of the reinforcing steel corrosion by potentialdynamic scan approach10.1007/s11595-012-0477-4 ↗
86. Characterization of embeddable potentiometric thick-film sensors for monitoring chloride penetration in concrete10.1016/j.snb.2015.07.056 ↗
87. Monitoring chloride ion penetration in concrete with different mineral admixtures based on embedded chloride ion selective electrodes10.1016/j.conbuildmat.2017.03.131 ↗
88. Examples of reinforcement corrosion monitoring by embedded sensors in concrete structures10.1016/j.cemconcomp.2009.05.007 ↗
89. A promising potential embeddable sensor for corrosion monitoring application in concrete structures10.1016/j.measurement.2006.09.008 ↗
90. Development of a galvanic sensor system for detecting the corrosion damage of the steel embedded in concrete structure10.1016/j.cemconres.2003.11.027 ↗
91. A wireless embedded passive sensor for monitoring the corrosion potential of reinforcing steel10.1088/0964-1726/22/7/075019 ↗
92. Remote corrosion monitoring of the RC structures using the electrochemical wireless energy-harvesting sensors and networks10.1016/j.ndteint.2011.06.007 ↗
93. Wireless sensor networks for temperature and humidity monitoring within concrete structures10.1016/j.conbuildmat.2012.11.087 ↗
94. Applications of smart piezoelectric materials in a wireless admittance monitoring system (WiAMS) to Structures—Tests in RC elements
95. Connecting to Concrete: Wireless Monitoring of Chloride ions in Concrete structures10.1016/j.proeng.2015.08.827 ↗
96. Condition survey with embedded sensors regarding reinforcement corrosion10.1002/maco.201206629 ↗
97. A New Corrosion Sensor to Determine the Start and Development of Embedded Rebar Corrosion Process at Coastal Concrete10.3390/s131013258 ↗
98. Temperature and loading effects of embedded smart piezoelectric sensor for health monitoring of concrete structures10.1016/j.conbuildmat.2014.11.067 ↗
99. Influence of Rapid Changes of Moisture Content in Concrete and Temperature on Corrosion Rate of Reinforcing Steel10.1016/j.proeng.2015.06.153 ↗
100. Evaluation of Maximum and Minimum Corrosion Rate of Steel Rebars in Concrete Structures, Based on Laboratory Measurements on Drilled Cores10.1016/j.proeng.2017.06.241 ↗