journal article·2017-06-20Open access

Levels of Organic Pollution Indicators in Groundwater at the Old Landfill and Waste Management Site

Eugeniusz Koda, Anna Miszkowska, Anna Sieczka

Applied Sciences· Volume 7· Issue 6

Abstract

The aim of this paper was to assess groundwater quality in a landfill and waste management site, with special regard to levels of organic pollution indicators: chemical oxygen demand (COD), biochemical oxygen demand (BOD), and total organic carbon (TOC). Analysis of specific indicators was conducted for piezometers located in the area of the Radiowo landfill, the composting plant and the facilities adjacent to the landfill. The article discusses the temporal and spatial changes of selected organic pollution indicators. Based on the results of groundwater monitoring, several maps of COD, BOD and TOC areal distribution were provided. Statistical distribution of monitoring data was presented using box-and-whisker plots. Pearson’s correlation coefficients between selected pollution indicators were measured with a significance level set at p < 0.01 and p < 0.05. The strongest correlation was observed between BOD and COD. The maximum BOD/COD ratio was observed at the level of 1.561 before the closure of the vertical barrier, whereas, at present, average values of this ratio are below 0.18. The results indicate significant improvement of groundwater quality in the landfill site after the closure of the vertical barrier. In particular, this refers to BOD values, which decreased even 160 times in the 1998–2016 monitoring period.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Landfill Environmental Impact Studies · Municipal Solid Waste Management · Groundwater flow and contamination studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Geotechnical Engineering, Faculty of Civil and Environmental Engineering, Warsaw University of Life Sciences, Nowoursynowska 159 St., 02-776 Warsaw, Poland

References (48)

Show source-provided references
1. Christensen, T.H., Cossu, R., and Stegmann, R. (1992). Landfilling of Waste: Leachate, Taylor & Francis.10.1201/9781482288933 ↗
2. (2017, June 19). Central Statistical Office: Warsaw, Poland, 2016, Available online: http://stat.gov.pl/obszary-tematyczne/infrastruktura-komunalna-nieruchomosci/nieruchomosci-budynki-infrastruktura-komunalna/infrastruktura-komunalna-w-2015-r-,3,13.html.
3. Household hazardous waste in municipal landfills: Contaminants in leachate10.1016/j.scitotenv.2004.07.002 ↗
4. Environmental impact of landfill on groundwater quality and agricultural soils in Nigeria10.17221/4/2011-SWR ↗
5. Klinck, B., and Stuart, M. (1999). Human Health Risk in Relation to Landfill Leachate Quality, British Geological Survey. Technical Report WC/99/17.
6. Organic indicators of groundwater pollution by a sanitary landfill10.1016/0043-1354(86)90062-X ↗
7. Biological and chemical oxygen demand as indicators of organic pollution of leachate and piezometric water from semi controlled, non-sanitary landfill in Novi Sad, Serbia
8. Landfill liners from dam reservoir sediments10.1515/sggw-2016-0004 ↗
9. Holland, H.D., Turekian, K.K., and Lollar, B.S. (2004). The groundwater geochemistry of waste disposal facilities. Treatise on Geochemistry. Environmental Geochemistry, Elsevier.
10. Sarsby, R.W. (2013). Environmental Geotechnics, Thomas Telford.10.1680/eg.41875 ↗
11. Characterization of the dissolved organic carbon fraction in landfill leachate-pol luted groundwater10.1016/S0043-1354(97)00202-9 ↗
12. Effect of Municipal Solid Waste Leachate on Ground Water Quality of Thiruvananthapuram District, Kerala, India
13. Gettinby, J.H. (1999). The Composition of Landfill Leachate and Its Interaction with Compacted Clay Liners. [Ph.D. Thesis, Manchester University (Bolton Institute)].
14. Sewage Treatment Efficacy of Sandy Soil Bed with Natural Clinoptilolite Assist Layer
15. Aseasonal Assessment of Groundwater Pollution due to Biochemical Oxygen Demand, Chemical Oxygen Demand and Elevated Temperatures in Enugu Northern Senatorial District, South East Nigeria
16. Soil contamination in landfills: A case study of a landfill in Czech Republic10.5194/se-7-239-2016 ↗
17. Environmental diagnosis methodology for municipal waste landfills10.1016/j.wasman.2005.02.019 ↗
18. Gworek, B., Dmuchowski, W., Koda, E., Marecka, M., Baczewska, A.H., Brągoszewska, P., Sieczka, A., and Osiński, P. (2016). Impact of the Municipal Solid Waste Łubna Landfill on Environmental Pollution by Heavy Metals. Water, 8.10.3390/w8100470 ↗
19. Influence of vertical barrier surrounding old sanitary landfill on eliminating transport of pollutants on the basis of numerical modelling and monitoring results
20. Areal Distribution of Ammonium Contamination of Soil-Water Environment in the Vicinity of Old Municipal Landfill Site with Vertical Barrier10.3390/w7062656 ↗
21. Koda, E., Sieczka, A., and Osiński, P. (2016). Ammonium concentration and migration in groundwater in the vicinity of waste management site located in the neighborhood of protected areas of Warsaw, Poland. Sustainability, 8.10.3390/su8121253 ↗
22. Koda, E., Tkaczyk, A., Lech, M., and Osiński, P. (2017). Application of Electrical Resistivity Data Sets for the Evaluation of the Pollution Concentration Level within Landfill Subsoil. Appl. Sci., 7.10.3390/app7030262 ↗
23. Evaluation of surface water and groundwater contamination in a MSW landfill area using hydrochemical analysis and electrical resistivity tomography: A case study in Sichuan province, Southwest China10.1007/s10661-017-5832-7 ↗
24. Impacts of leachate percolation on ground water quality: A case study of Dhanbad City10.30955/gnj.001377 ↗
25. Local water quality monitoring on surroundings of the sanitary landfill
26. Manassero, M., Dominijanni, A., Foti, S., and Musso, G. (2013). Flow numerical modeling for efficiency assessment of vertical barriers in landfills. Coupled Phenomena in Environmental Geotechnics: From Theoretical and Experimental Research to Practical Applications, Proceedings of International Symposium TC215 ISSMGE, Torino, Italy, 1–3 July 2013, CRC Press.10.1201/b15004 ↗
27. Nielsen, D.M. (2005). Practical Handbook of Environmental Site Characterization and Ground-Water Monitoring, CRC Press. [2nd ed.].10.1201/9781420032246 ↗
28. (2012). Water Quality. Sampling. Part 3: Preservation and Handling of Water Samples, International Organization for Standardization. EN ISO 5667-3.
29. (2009). Water Quality. Sampling. Part 11: Guidance on Sampling of Groundwaters, International Organization for Standardization. ISO 5667-11.
30. (2002). Water Quality: Determination of the Chemical Oxygen Demand Index (ST-COD)–Small-Scale Sealed-Tube Method, International Organization for Standardization. PN-ISO 15705:2005P.
31. (2002). Water Quality; Determination of Biochemical Oxygen Demand after n Days (BODn)–Part 2: Method for Undiluted Samples (ISO 5815:1989, Modified), Polish Committee for Standardization. PN-EN 1899-2:2002P.
32. (1999). Water Analysis: Guidelines for the Determination of Total Organic Carbon (TOC) and Dissolved Organic Carbon (DOC), Polish Committee for Standardization. PN-EN 1484:1999P.
33. (2012). Water Quality: Determination of pH, International Organization for Standardization. PN-EN ISO 10523:2012.
34. (1999). Water Quality: Determination of Electrical Conductivity, Polish Committee for Standardization. PN-EN 27888:1999.
35. (2017, June 19). Regulation of the Minister of Environment Dated 21 December 2015 on the Criteria and Method of Evaluating the Underground Water Condition (Journal of Laws 2016, Item 85), Available online: http://isap.sejm.gov.pl/DetailsServlet?id=WDU20160000085.
36. Assessment of groundwater contamination by leachate near a municipal solid waste landfill
37. Leachate characterization and assessment of ground-water pollution near municipal solid waste landfill site10.1007/s10661-006-1505-7 ↗
38. Hazelton, P., and Murphy, B. (2007). Interpreting Soil Test Results: What Do All the Numbers Mean?, CSIRO Publishing.10.1071/9780643094680 ↗
39. Environmental impacts with waste disposal practices in a suburban municipality in Sri Lanka10.1504/IJEWM.2010.033987 ↗
40. Ground water quality near municipal solid waste dumping site at Thirupperumthurai, Batticaloa
41. Fate and transport of pollutants through a municipal solid waste landfill leachate in Sri Lanka
42. National Agency for Food and Drug Administration and Control (NAFDAC) (1999). Guidelines for Registration and Production of Packaged Water in Nigeria.
43. BOD/COD ratio as an indicator for pollutants leaching from landfill10.7763/JOCET.2014.V2.137 ↗
44. Nininen, M., Kalliokoski, P., and Parjala, E. (1993, January 6–9). Effect of organic contaminants in landfill leachates on groundwater quality in Finland: Groundwater Quality Management. Proceedings of the GQM 93 Conference, Tallinn, Estonia.
45. Uz, G., Turak, F., and Afşar, H. (October, January 29). Research of BOD and COD values of wastewaters that contain organic materials. 4th Aegean Analytical Chemistry Days, Kusadasi, Turkey.
46. Photodegradation of Acid Orange 7 in a UV/acetylacetone Process10.1016/j.chemosphere.2013.08.082 ↗
47. Evans, J.D. (1996). Straightforward Statistics for the Behavioral Sciences. Brooks/Cole Publishing.
48. An assessment of the organic pollution indicator levels of River Benue in Adamawa State, Nigeria