DC IR-Drop Analysis of Multilayered Power Distribution Network by Discontinuous Galerkin Method With Thermal Effects Incorporated
Source abstract
Abstract
Due to the temperature-dependent resistivity of power distribution network (PDN) interconnects, a wiser and necessary strategy is to proceed the electrical-thermal cosimulation in order to include the thermal effects caused by Joule heating. As a natural domain decomposition method (DDM), in this article, a discontinuous Galerkin (DG) method is proposed to facilitate the steady-state electrical and thermal coanalysis. With the intention to avoid solving a globally coupled steady-state matrix system equations resulted from the implicit numerical flux in DG, the block Thomas method is deployed to solve the entire domain in a subdomain-by-subdomain scheme. As a direct solver, the block Thomas method is free of convergence problem frequently occurring in iterative methods, such as block Gauss-Seidel method. The capability of the proposed DG method in handling multiscale and complex 3-D PDNs is validated by several representative examples.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electromagnetic Compatibility and Noise Suppression · Electromagnetic Simulation and Numerical Methods · Electromagnetic Scattering and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. 10.1109/TAP.2014.230729410.1109/TAP.2014.2307294 ↗
2. 10.1109/TMTT.2016.264031210.1109/TMTT.2016.2640312 ↗
3. fletcher · Computational Techniques for Fluid Dynamics · 1991
4. jin · The Finite Element Method in Electromagnetics · 2003
5. 10.1137/061304510.1137/0613045 ↗
6. 10.1137/S003614290037100310.1137/S0036142900371003 ↗
7. 10.1109/TCPMT.2017.266625910.1109/TCPMT.2017.2666259 ↗
8. 10.1109/TEMC.2019.291103910.1109/TEMC.2019.2911039 ↗
9. 10.1016/j.jappgeo.2015.01.00610.1016/j.jappgeo.2015.01.006 ↗
10. 10.1109/TED.2005.84812510.1109/TED.2005.848125 ↗
11. 10.1109/TEMC.2010.204538210.1109/TEMC.2010.2045382 ↗
12. 10.1098/rspa.2011.070810.1098/rspa.2011.0708 ↗
13. 10.1109/TCPMT.2010.210177010.1109/TCPMT.2010.2101770 ↗
14. Transient electrical-thermal analysis of 3-D power distribution network with FETI-enabled parallel computing10.1109/TCPMT.2014.2345651 ↗
15. 10.1109/TCPMT.2013.227527110.1109/TCPMT.2013.2275271 ↗
16. Overview of signal integrity and EMC design technologies on PCB: Fundamentals and latest progress10.1109/TEMC.2013.2257796 ↗
17. 10.1109/MEMC.2015.740718810.1109/MEMC.2015.7407188 ↗
18. 10.1109/TMTT.2013.226108510.1109/TMTT.2013.2261085 ↗