journal article·2019-09

Reliability Challenges in Fabrication of Flexible Hybrid Electronics for Human Performance Monitors: A System-Level Study

Varun V. Soman, Donggeon Han, Ana Claudia Arias, Kanad Ghose, Mark D. Poliks, James N. Turner, Yasser Khan, Madina Zabran, Mark Schadt, Paul Hart, Michael Shay, Frank D. Egitto, Konstantinos I. Papathomas, Natasha A. D. Yamamoto

Publisher page

Abstract

Flexible hybrid electronics (FTIE) interface rigid electronic components with flexible sensors, circuits, and substrates. This paper reports the reliability improvement of an FTIE human performance monitor (TIPM), designed to monitor electrocardiography (ECG) signals. The 50.8 mm × 50.8 mm TIPM is fabricated on Kapton TIN polyimide (PI) substrate with flexible gold (Au) ECG electrodes on one side of the substrate and rigid electronic components for signal processing and communication mounted on the other side of the substrate. Our previously reported TIPMs demonstrated reliability issues due to: 1) cracking of the copper (Cu) circuitry and 2) thinning and lack of adhesion at the printed Au and plated Cu interface that connected printed sensors to the Cu circuitry. Both failure mechanisms resulted in electrical opens in the circuit, which caused device failure. We explored effects of different design parameters, such as PI substrate thickness (50 versus 125 μm), Cu circuit thickness (2 versus 6 μm), solder reflow temperature [205 °C for Tin-Lead (Sn-Pb) versus 175 °C for Tin-Bismuth (Sn-Bi) solder], solder pad design, and optimized inkjet printing (printing on bare Cu versus Au-plated Cu) on improving FTIE reliability. Test vehicles (TVs) with different combinations of these factors were fabricated and bend-tested to determine the most robust configuration. TVs with 50-μm-thick PI substrate, 6-μm-thick Cu circuit, Sn-Bi solder, redesigned solder pads with rounded corners, and printed Au traces on Au plated Cu pads demonstrated the best reliability results.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Neuroscience and Neural Engineering · Conducting polymers and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. 10.1145/312656810.1145/3126568 ↗
2. 10.1126/sciadv.160147310.1126/sciadv.1601473 ↗
3. 10.1109/TBME.2012.219028810.1109/TBME.2012.2190288 ↗
4. 10.3390/s14081473210.3390/s140814732 ↗
5. 10.1109/MCOM.2012.612253010.1109/MCOM.2012.6122530 ↗
6. 10.1109/ICRITO.2016.778503210.1109/ICRITO.2016.7785032 ↗
7. 10.1109/APCCAS.2014.703274910.1109/APCCAS.2014.7032749 ↗
8. 10.1002/adfm.20160376310.1002/adfm.201603763 ↗
9. 10.1109/ECTC.2016.39510.1109/ECTC.2016.395 ↗
10. 10.1109/ECTC.2018.0028010.1109/ECTC.2018.00280 ↗
11. 10.4071/isom-2017-WA23_13710.4071/isom-2017-WA23_137 ↗
12. 10.1109/TMSCS.2016.263734510.1109/TMSCS.2016.2637345 ↗
13. 10.1109/TBME.2014.236999110.1109/TBME.2014.2369991 ↗
14. 10.1109/LED.2013.228993210.1109/LED.2013.2289932 ↗
15. 10.1016/j.bios.2013.11.03910.1016/j.bios.2013.11.039 ↗
16. 10.1038/ncomms757510.1038/ncomms7575 ↗
17. gao · Heart Monitor Using Capacitive ECG Electrodes · 0
18. 10.1021/acsnano.6b0135510.1021/acsnano.6b01355 ↗
19. 10.1109/MEMSYS.2017.786338510.1109/MEMSYS.2017.7863385 ↗
20. 10.1002/adma.20150436610.1002/adma.201504366 ↗
21. 10.1038/ncomms283210.1038/ncomms2832 ↗
22. 10.1002/adfm.20150456010.1002/adfm.201504560 ↗
23. Wearable and highly sensitive graphene strain sensors for human motion monitoring10.1002/adfm.201400379 ↗
24. 10.1109/ISSE.2016.756318510.1109/ISSE.2016.7563185 ↗
25. Electrical failure and damage analysis of Multi-Layer metal films on flexible substrate during cyclic bending deformation
26. 10.1109/ECTC.2012.624881010.1109/ECTC.2012.6248810 ↗
27. 10.1109/JPHOTOV.2016.258379210.1109/JPHOTOV.2016.2583792 ↗
28. 10.1039/C6TC01340F10.1039/C6TC01340F ↗
29. 10.1117/12.231210310.1117/12.2312103 ↗
30. 10.1007/s10853-015-9643-310.1007/s10853-015-9643-3 ↗