Chip to Facility Ramifications of Containment Solution on IT Airflow and Uptime

Husam A. Alissa, Kourosh Nemati, Bahgat G. Sammakia, Ken Schneebeli, Roger R. Schmidt, Mark J. Seymour

Publisher page

Abstract

We developed a generalized testing methodology in which IT fans' internal and external impedance effects are collapsed into a single curve (i.e., flow curve). Such curves can give accurate flow rate predictions of the IT equipment based on RPM logging. Flow curves cover the three possible airflow regions for IT in a contained environment. The experimental procedure is introduced to rank IT equipment based on its air systems, and the flow regions are correlated with the CPU performance. The strength of the IT air system is characterized by the free delivery and the critical pressure points. In addition, the experimentally obtained active flow curves can be used as a numerical boundary condition in various containment designs. Accordingly, for the first time in the literature, the aerodynamic interaction of IT with different air systems in the containment (i.e., BladeCenters, servers, and switches) can numerically be investigated. It is found that stacking IT in a contained environment with no physical consideration can lead to radical reliability problems. The region of reverse flow is discovered to be very possible upon events in the data center. In such a case, the weak IT (e.g., 1U switch) behaves as an open leakage into the sealed containment. On the other hand, at the critical pressure point, minimum forced convection occurs in the weak IT, leading to CPU overheating.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fluid Dynamics and Heat Transfer · Aerosol Filtration and Electrostatic Precipitation · Electrostatic Discharge in Electronics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. idelchik · Fluid Dynamics of Industrial Equipment Flow Distribution Design Methods · 1989
2. 6Sigma 9 3 User Manual · 2015
3. A compact server model for transient data center simulations
4. 10.1115/IPACK2007-3350810.1115/IPACK2007-33508 ↗
5. 10.1109/ITHERM.2010.550141310.1109/ITHERM.2010.5501413 ↗
6. 10.1115/IPACK2013-7321410.1115/IPACK2013-73214 ↗
7. 10.1115/IMECE2006-1371110.1115/IMECE2006-13711 ↗
8. 10.1109/ITHERM.2014.689235910.1109/ITHERM.2014.6892359 ↗
9. 10.1109/SEMI-THERM.2014.689223810.1109/SEMI-THERM.2014.6892238 ↗
10. 10.1109/SEMI-THERM.2015.710015710.1109/SEMI-THERM.2015.7100157 ↗
11. 10.1115/IPACK2015-4823410.1115/IPACK2015-48234 ↗
12. 10.1109/ITHERM.2012.623141510.1109/ITHERM.2012.6231415 ↗
13. 10.1109/ITHERM.2014.689236210.1109/ITHERM.2014.6892362 ↗
14. Ramifications of server airflow leakage with aisle containment
15. Thermal profile of a high-density data center-methodology to thermally characterize a data center
16. 10.1109/ITHERM.2014.689236110.1109/ITHERM.2014.6892361 ↗
17. Datacom Equipment Power Trends and Cooling Applications · 2005
18. Cost of Data Center Outages · 2013
19. Data Center Networking Equipment—Issues and Best Practices · 2015
20. Thermal profile of world’s 3rd fastest supercomputer—IBM’s ASCI purple cluster
21. Methods and techniques for measuring and improving data center best practices
22. 10.1115/IPACK2005-7327310.1115/IPACK2005-73273 ↗
23. geng · Data Center Handbook · 2012
24. 10.1115/1.400158910.1115/1.4001589 ↗
25. herrlin · Thermal Guidelines for Data Processing Environments · 2012
26. 10.1109/SEMI-THERM.2013.652683310.1109/SEMI-THERM.2013.6526833 ↗
27. In row cooling options for high density IT applications
28. Cooling entire data centers using only row cooling
29. 10.1115/IPACK2015-4823710.1115/IPACK2015-48237 ↗
30. Performance of temperature controlled perimeter and row-based cooling systems in open and containment environment
31. 10.1115/IPACK2013-7321910.1115/IPACK2013-73219 ↗
32. 10.1115/IPACK2015-4824410.1115/IPACK2015-48244 ↗