journal article·2001

Harmonisation of test and calculation methods to evaluate the heat transfer across building components

Hans-Jürgen Hartmann, Konrad Huber, Josef Schmid

High Temperatures-High Pressures· Volume 33· Issue 3
Publisher page

Abstract

Draft CEN (and ISO) standards for hot-box U value measurements of windows and insulated glazing units require calibration measurements to be carried out with glazed calibration panels of known thermal conductance. This panel design has been validated by five European partner laboratories (under the leadership of the National Physical Laboratory, Middlesex, UK) which each made panels to an agreed specification and carried out the calibration procedures specified in prEN 12412-1. The panels were then circulated to the other partner laboratories who measured their thermal transmittance, U, values using the CEN procedure. The work demonstrated that the uncertainty of the subsequent U value measurements made by the calibration data were within ±7%, The sensitivity of the CEN measurement procedures to the calculated conductance and temperature measurement accuracy is discussed and some improvements are suggested for the draft standards. The experience gained from the comparison on the calibration panels provides the chance to establish improved measurement as well as calibration procedures.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Building Energy and Comfort Optimization · Thermography and Photoacoustic Techniques · Structural Analysis of Composite Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.