Stimulus-active polymer actuators for next-generation microfluidic devices
Source abstract
Abstract
Microfluidic devices have not yet evolved into commercial off-the-shelf products. Although highly integrated microfluidic structures, also known as lab-on-a-chip (LOC) and micrototal-analysis-system (µTAS) devices, have consistently been predicted to revolutionize biomedical assays and chemical synthesis, they have not entered the market as expected. Studies have identified a lack of standardization and integration as the main obstacles to commercial breakthrough. Soft microfluidics, the utilization of a broad spectrum of soft materials (i.e., polymers) for realization of microfluidic components, will make a significant contribution to the proclaimed growth of the LOC market. Recent advances in polymer science developing novel stimulus-active soft-matter materials may further increase the popularity and spreading of soft microfluidics. Stimulus-active polymers and composite materials change shape or exert mechanical force on surrounding fluids in response to electric, magnetic, light, thermal, or water/solvent stimuli. Specifically devised actuators based on these materials may have the potential to facilitate integration significantly and hence increase the operational advantage for the end-user while retaining cost-effectiveness and ease of fabrication. This review gives an overview of available actuation concepts that are based on functional polymers and points out promising concepts and trends that may have the potential to promote the commercial success of microfluidics.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Dielectric materials and actuators · Microfluidic and Capillary Electrophoresis Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. T.M. Squires, S.R. Quake, Microfluidics: fluid physics at the nanoliter scale. Rev. Mod. Phys. 77(3), 977 (2005)10.1103/RevModPhys.77.977 ↗
2. J. Castillo-León, W.E. Svendsen (eds.), Lab-on-a-Chip Devices and Micro-Total Analysis Systems: A Practical Guide (Springer, New York, 2014)
3. L.R. Volpatti, A.K. Yetisen, Commercialization of microfluidic devices. Trends Biotechnol. 32(7), 347–350 (2014)10.1016/j.tibtech.2014.04.010 ↗
4. I.E. Araci, P. Brisk, Recent developments in microfluidic large scale integration. Curr. Opin. Biotechnol. 25, 60–68 (2014)10.1016/j.copbio.2013.08.014 ↗
5. Y. Temiz, R.D. Lovchik, G.V. Kaigala, E. Delamarche, Lab-on-a-chip devices: how to close and plug the lab? Microelectron. Eng. 132, 156–175 (2015)10.1016/j.mee.2014.10.013 ↗
6. P. Gravesen, J. Branebjerg, O.S. Jensen, Microfluidics-a review. J. Micromech. Microeng. 3(4), 168–182 (1993)10.1088/0960-1317/3/4/002 ↗
7. H. Becker, C. Gärtner, Polymer microfabrication technologies for microfluidic systems. Anal. Bioanal. Chem. 390(1), 89–111 (2008)10.1007/s00216-007-1692-2 ↗
8. G. Spizz, L. Young, R. Yasmin, Z. Chen, T. Lee, D. Mahoney, T. Roswech, Rheonix CARD® technology: AN innovative and fully automated molecular diagnostic device. Point of Care 11(1), 42–51 (2012)10.1097/POC.0b013e318222e184 ↗
9. D.J. Laser, J.G. Santiago, A review of micropumps. J. Micromech. Microeng. 14(6), R35 (2004)10.1088/0960-1317/14/6/R01 ↗
10. K.W. Oh, C.H. Ahn, A review of microvalves. J. Micromech. Microeng. 16(5), R13 (2006)10.1088/0960-1317/16/5/R01 ↗
11. D. Dumont-Fillon, H. Tahriou, C. Conan, E. Chappel, Insulin micropump with embedded pressure sensors for failure detection and delivery of accurate monitoring. Micromachines 5(4), 1161–1172 (2014)10.3390/mi5041161 ↗
12. D.C. Duffy, J.C. McDonald, O.J. Schueller, G.M. Whitesides, Rapid prototyping of microfluidic systems in poly (dimethylsiloxane). Anal. Chem. 70(23), 4974–4984 (1998)10.1021/ac980656z ↗
13. J.R. Anderson, D.T. Chiu, R.J. Jackman, O. Cherniavskaya, J.C. McDonald, H. Wu, S.H. Whitesides, G.M. Whitesides, Fabrication of topologically complex three-dimensional microfluidic systems in PDMS by rapid prototyping. Anal. Chem. 72(14), 3158–3164 (2000)10.1021/ac9912294 ↗
14. J.C. McDonald, G.M. Whitesides, Poly (dimethylsiloxane) as a material for fabricating microfluidic devices. Acc. Chem. Res. 35(7), 491–499 (2002)10.1021/ar010110q ↗
15. F. Schneider, T. Fellner, J. Wilde, U. Wallrabe, Mechanical properties of silicones for MEMS. J. Micromech. Microeng. 18(6), 065008 (2008)10.1088/0960-1317/18/6/065008 ↗
16. P. Jothimuthu, A. Carroll, A.A.S. Bhagat, G. Lin, J.E. Mark, I. Papautsky, Photodefinable PDMS thin films for microfabrication applications. J. Micromech. Microeng. 19(4), 045024 (2009)10.1088/0960-1317/19/4/045024 ↗
17. D.P.J. Cotton, A. Popel, I.M. Graz, S.P. Lacour, Photopatterning the mechanical properties of polydimethylsiloxane films. J. Appl. Phys. 109(5), 054905 (2011)10.1063/1.3552917 ↗
18. A.I. Egunov, J.G. Korvink, V.A. Luchnikov, Polydimethylsiloxane bilayer films with an embedded spontaneous curvature. Soft Matter. 12(1), 45–52 (2016)10.1039/C5SM01139F ↗
19. Y. Tanaka, K. Sato, T. Shimizu, M. Yamato, T. Okano, T. Kitamori, Biological cells on microchips: new technologies and applications. Biosens. Bioelectron. 23(4), 449–458 (2007)10.1016/j.bios.2007.08.006 ↗
20. M. Pilarek, P. Neubauer, U. Marx, Biological cardio-micro-pumps for microbioreactors and analytical micro-systems. Sens. Actuators B: Chem. 156(2), 517–526 (2011)10.1016/j.snb.2011.02.014 ↗
21. Y. Tanaka, H. Fujita, Fluid driving system for a micropump by differentiating iPS cells into cardiomyocytes on a tent-like structure. Sens. Actuators B: Chem. 210, 267–272 (2015)10.1016/j.snb.2014.12.069 ↗
22. R.W. Carlsen, M. Sitti, Bio-hybrid cell-based actuators for microsystems. Small 10(19), 3831–3851 (2014)10.1002/smll.201400384 ↗
23. L. Vannozzi, L. Ricotti, M. Cianchetti, C. Bearzi, C. Gargioli, R. Rizzi, P. Dario, A. Menciassi, Self-assembly of polydimethylsiloxane structures from 2D to 3D for bio-hybrid actuation. Bioinspiration Biomim 10(5), 056001 (2015)10.1088/1748-3190/10/5/056001 ↗
24. Z. Gao, H. Li, X. Chen, H.P. Zhang, Using confined bacteria as building blocks to generate fluid flow. Lab Chip 15(24), 4555–4562 (2015)10.1039/C5LC01093D ↗
25. S.V. Anand, T.A. Saif, Emergent dynamics of cardiomyocyte clusters on deformable polymeric substrates. Extreme Mech. Lett. (2015). doi: 10.1016/j.eml.2015.09.00810.1016/j.eml.2015.09.008 ↗
26. B.L. Gray, A review of magnetic composite polymers applied to microfluidic devices. J. Electrochem. Soc. 161(2), B3173–B3183 (2014)10.1149/2.023402jes ↗
27. J. Li, M. Zhang, L. Wang, W. Li, P. Sheng, W. Wen, Design and fabrication of microfluidic mixer from carbonyl iron–PDMS composite membrane. Microfluidics and nanofluidics 10(4), 919–925 (2011)10.1007/s10404-010-0712-2 ↗
28. J.J. Nagel, G. Mikhail, H. Noh, J. Koo, Magnetically actuated micropumps using an Fe-PDMS composite membrane, in Smart Structures and Materials (International Society for Optics and Photonics, 2006), pp. 617213–61721310.1117/12.658012 ↗
29. W. Hilber, B. Jakoby, A magnetic membrane actuator in composite technology utilizing diamagnetic levitation. IEEE Sens. J. 13(7), 2786–2791 (2013)10.1109/JSEN.2013.2260144 ↗
30. W. Hilber, B. Jakoby, Controlled liquid flow in a microfluidic network with pressure sensitive valves based on polydimethylsiloxane (PDMS)/neodymium (NdFeB) composites. Proc. Eng. 47, 382–385 (2012)10.1016/j.proeng.2012.09.163 ↗
31. S. Marchi, A. Casu, F. Bertora, A. Athanassiou, D. Fragouli, Highly magneto-responsive elastomeric films created by a two-step fabrication process. ACS Appl. Mater. Interfaces 7(34), 19112–19118 (2015)10.1021/acsami.5b04711 ↗
32. J.M. den Toonder, P.R. Onck, Microfluidic manipulation with artificial/bioinspired cilia. Trends Biotechnol. 31(2), 85–91 (2013)10.1016/j.tibtech.2012.11.005 ↗
33. J.V. Timonen, C. Johans, K. Kontturi, A. Walther, O. Ikkala, R.H. Ras, A facile template-free approach to magnetodriven, multifunctional artificial cilia. ACS Appl. Mater. Interfaces 2(8), 2226–2230 (2010)10.1021/am100244x ↗
34. Y. Wang, Y. Gao, H.M. Wyss, P.D. Anderson, J.M. den Toonder, Artificial cilia fabricated using magnetic fiber drawing generate substantial fluid flow. Microfluid. Nanofluid. 18(2), 167–174 (2015)10.1007/s10404-014-1425-8 ↗
35. M. Riahi, E. Alizadeh, Fabrication of a 3D active mixer based on deformable Fe-doped PDMS cones with magnetic actuation. J. Micromech. Microeng. 22(11), 115001 (2012)10.1088/0960-1317/22/11/115001 ↗
36. M. Rahbar, L. Shannon, B.L. Gray, Microfluidic active mixers employing ultra-high aspect-ratio rare-earth magnetic nano-composite polymer artificial cilia. J. Micromech. Microeng. 24(2), 025003 (2014)10.1088/0960-1317/24/2/025003 ↗
37. B. Zhou, W. Xu, A.A. Syed, Y. Chau, L. Chen, B. Chew, W. Wen, Design and fabrication of magnetically functionalized flexible micropillar arrays for rapid and controllable microfluidic mixing. Lab Chip 15(9), 2125–2132 (2015)10.1039/C5LC00173K ↗
38. B.L. Fiser, A.R. Shields, M.R. Falvo, R. Superfine, Highly responsive core-shell microactuator arrays for use in viscous and viscoelastic fluids. J. Micromech. Microeng. 25(2), 025004 (2015)10.1088/0960-1317/25/2/025004 ↗
39. F. Fahrni, M.W. Prins, L.J. van Ijzendoorn, Micro-fluidic actuation using magnetic artificial cilia. Lab Chip 9(23), 3413–3421 (2009)10.1039/b908578e ↗
40. F. Liu, G. Alici, B. Zhang, S. Beirne, W. Li, Fabrication and characterization of a magnetic micro-actuator based on deformable Fe-doped PDMS artificial cilium using 3D printing. Smart Mater. Struct. 24(3), 035015 (2015)10.1088/0964-1726/24/3/035015 ↗
41. O.O. Osman, H. Shintaku, S. Kawano, Development of micro-vibrating flow pumps using MEMS technologies. Microfluid. Nanofluid. 13(5), 703–713 (2012)10.1007/s10404-012-0988-5 ↗
42. W. Hilber, S. Clara, B. Jakoby, Magnetic circuits based on polymer composites for controlled actuation of a ferromagnetic sphere at a microfluidic junction. In Proceedings of Sensors, (IEEE Sensors, Baltimore, 2013) pp. 1–410.1109/ICSENS.2013.6688297 ↗
43. S. Peng, M. Zhang, X. Niu, W. Wen, P. Sheng, Z. Liu, J. Shi, Magnetically responsive elastic microspheres. Appl. Phys. Lett. 92(1), 012108 (2008)10.1063/1.2830620 ↗
44. D. Liu, K. Bastiaansen, D. Broer, P. Onck, J. den Toonder, Inkjet printing of magnetic/non-magnetic polymer microfluidic actuators, in Proceedings of 14th MicroTAS, 2010, pp. 515–517
45. B. Samel, P. Griss, G. Stemme, A thermally responsive PDMS composite and its microfluidic applications. J. Microelectromech. Syst. 16(1), 50–57 (2007)10.1109/JMEMS.2006.886025 ↗
46. B. Samel, J. Chretien, R. Yue, P. Griss, G. Stemme, Wafer-level process for single-use buckling-film microliter-range pumps. J. Microelectromech. Syst. 16(4), 795–801 (2007)10.1109/JMEMS.2007.901642 ↗
47. L. Metref, F. Bianchi, V. Vallet, N. Blanc, R. Goetschmann, P. Renaud, Microfluidic system based on thermoexpandable polymer for on chip blood coagulation testing. Micro Nanosyst. 1(1), 41–45 (2009)10.2174/1876402910901010041 ↗
48. G.P. Kanakaris, N. Fatsis-Kavalopoulos, L.G. Alexopoulos, Laser activated single-use micropumps. Sens. Actuators B: Chem. 220, 549–556 (2015)10.1016/j.snb.2015.04.101 ↗
49. J. Loomis, P. Xu, B. Panchapakesan, Stimuli-responsive transformation in carbon nanotube/expanding microsphere–polymer composites. Nanotechnology 24(18), 185703 (2013)10.1088/0957-4484/24/18/185703 ↗
50. L.Z. Chen, C.H. Liu, C.H. Hu, S.S. Fan, Electrothermal actuation based on carbon nanotube network in silicone elastomer. Appl. Phys. Lett. 92(26), 263104 (2008)10.1063/1.2955513 ↗
51. S. Cheng, Z. Wu, Microfluidic electronics. Lab Chip 12(16), 2782–2791 (2012)10.1039/c2lc21176a ↗
52. A.P. Gerratt, B. Balakrisnan, I. Penskiy, S. Bergbreiter, Dielectric elastomer actuators fabricated using a micro-molding process. Smart Mater. Struct. 23(5), 055004 (2014)10.1088/0964-1726/23/5/055004 ↗
53. X.Z. Niu, S.L. Peng, L.Y. Liu, W.J. Wen, P. Sheng, Characterizing and patterning of PDMS-based conducting composites. Adv. Mater. 19(18), 2682 (2007)10.1002/adma.200602515 ↗
54. F. Borghi, C. Melis, C. Ghisleri, A. Podestà, L. Ravagnan, L. Colombo, P. Milani, Stretchable nanocomposite electrodes with tunable mechanical properties by supersonic cluster beam implantation in elastomers. Appl. Phys. Lett. 106(12), 121902 (2015)10.1063/1.4916350 ↗
55. J.D. Tice, T.A. Bassett, A.V. Desai, C.A. Apblett, P.J. Kenis, A monolithic poly (dimethylsiloxane) electrostatic actuator for controlling integrated pneumatic microsystems. Sens. Actuators A: Phys. 196, 22–29 (2013)10.1016/j.sna.2013.03.020 ↗
56. L. Qu, Q. Peng, L. Dai, G.M. Spinks, G.G. Wallace, R.H. Baughman, Carbon nanotube electroactive polymer materials: opportunities and challenges. MRS Bull. 33(03), 215–224 (2008)10.1557/mrs2008.47 ↗
57. U. Kosidlo, M. Omastová, M. Micusík, G. Ćirić-Marjanović, H. Randriamahazaka, T. Wallmersperger, A. Aabloo, I. Kolaric, T. Bauernhansl, Nanocarbon based ionic actuators—a review. Smart Mater. Struct. 22(10), 104022 (2013)10.1088/0964-1726/22/10/104022 ↗
58. L. Wang, M. Zhang, J. Li, X. Gong, W. Wen, Logic control of microfluidics with smart colloid. Lab Chip 10(21), 2869–2874 (2010)10.1039/c0lc00003e ↗
59. C. Goll, W. Bacher, B. Büstgens, D. Maas, W. Menz, W.K. Schomburg, Microvalves with bistable buckled polymer diaphragms. J. Micromech. Microeng. 6(1), 77 (1996)10.1088/0960-1317/6/1/017 ↗
60. W.K. Schomburg, C. Goll, Design optimization of bistable microdiaphragm valves. Sens. Actuators A: Phys. 64(3), 259–264 (1998)10.1016/S0924-4247(97)01612-9 ↗
61. G.E. Song, K.H. Kim, Y.P. Lee, Simulation and experiments for a phase-change actuator with bistable membrane. Sens. Actuators A: Phys. 136(2), 665–672 (2007)10.1016/j.sna.2006.12.018 ↗
62. B. Yang, B. Wang, W.K. Schomburg, A thermopneumatically actuated bistable microvalve. J. Micromech. Microeng. 20(9), 095024 (2010)10.1088/0960-1317/20/9/095024 ↗
63. A. Chen, T. Pan, Manually operatable on-chip bistable pneumatic microstructures for microfluidic manipulations. Lab Chip 14(17), 3401–3408 (2014)10.1039/C4LC00540F ↗
64. R. Pelrine, R. Kornbluh, Q. Pei, J. Joseph, High-speed electrically actuated elastomers with strain greater than 100%. Science 287, 836–839 (2000)10.1126/science.287.5454.836 ↗
65. N. Goulbourne, E. Mockensturm, M. Frecker, A nonlinear model for dielectric elastomer membranes. J. Appl. Mech. 72(6), 899–906 (2005)10.1115/1.2047597 ↗
66. J.J. Loverich, I. Kanno, H. Kotera, Concepts for a new class of all-polymer micropumps. Lab Chip 6(9), 1147–1154 (2006)10.1039/b605525g ↗
67. C. Murray, D. McCoul, E. Sollier, T. Ruggiero, X. Niu, Q. Pei, D. Di Carlo, Electro-adaptive microfluidics for active tuning of channel geometry using polymer actuators. Microfluid. Nanofluid. 14(1–2), 345–358 (2013)10.1007/s10404-012-1055-y ↗
68. Y. Tanaka, T. Fujikawa, Y. Kazoe, T. Kitamori, An active valve incorporated into a microchip using a high strain electroactive polymer. Sens. Actuators B: Chem. 184, 163–169 (2013)10.1016/j.snb.2013.04.025 ↗
69. F. Carpi, G. Frediani, S. Turco, D. De Rossi, Bioinspired tunable lens with muscle-like electroactive elastomers. Adv. Funct. Mater. 21(21), 4152–4158 (2011)10.1002/adfm.201101253 ↗
70. S. Shian, R.M. Diebold, D.R. Clarke, Tunable lenses using transparent dielectric elastomer actuators. Opt. Express 21(7), 8669–8676 (2013)10.1364/OE.21.008669 ↗
71. L. Maffli, S. Rosset, M. Ghilardi, F. Carpi, H. Shea, Ultrafast All-Polymer Electrically Tunable Silicone Lenses. Adv. Funct. Mater. 25(11), 1656–1665 (2015)10.1002/adfm.201403942 ↗
72. A. Lamberti, M. Di Donato, A. Chiappone, F. Giorgis, G. Canavese, Tunable electromechanical actuation in silicone dielectric film. Smart Mater. Struct 23(10), 105001 (2014)10.1088/0964-1726/23/10/105001 ↗
73. T. Hoffstadt, J. Maas, Analytical modeling and optimization of DEAP-based multilayer stack-transducers. Smart Mater. Struct. 24(9), 094001 (2015)10.1088/0964-1726/24/9/094001 ↗
74. M. Follador, A.T. Conn, J. Rossiter, Bistable minimum energy structures (BiMES) for binary robotics. Smart Mater. Struct. 24(6), 065037 (2015)10.1088/0964-1726/24/6/065037 ↗
75. L. Zhang, D. Wang, P. Hu, J.W. Zha, F. You, S.T. Li, Z.M. Dang, Highly improved electro-actuation of dielectric elastomers by molecular grafting of azobenzenes to silicon rubber. J. Mater. Chem. C 3(19), 4883–4889 (2015)10.1039/C5TC00368G ↗
76. M. Kollosche, G. Kofod, Z. Suo, J. Zhu, Temporal evolution and instability in a viscoelastic dielectric elastomer. J. Mech. Phys. Solids 76, 47–64 (2015)10.1016/j.jmps.2014.11.013 ↗
77. N. Pekas, Q. Zhang, M. Nannini, D. Juncker, Wet-etching of structures with straight facets and adjustable taper into glass substrates. Lab Chip 10(4), 494–498 (2010)10.1039/B912770D ↗
78. M.P. Chang, M.M. Maharbiz, Electrostatically-driven elastomer components for user-reconfigurable high density microfluidics. Lab Chip 9(9), 1274–1281 (2009)10.1039/b813244e ↗
79. J.D. Tice, A.V. Desai, T.A. Bassett, C.A. Apblett, P.J. Kenis, Control of pressure-driven components in integrated microfluidic devices using an on-chip electrostatic microvalve. RSC Adv. 4(93), 51593–51602 (2014)10.1039/C4RA10341F ↗
80. A.V. Desai, J.D. Tice, C.A. Apblett, P.J. Kenis, Design considerations for electrostatic microvalves with applications in poly (dimethylsiloxane)-based microfluidics. Lab Chip 12(6), 1078–1088 (2012)10.1039/c2lc21133e ↗
81. E. Yıldırım, M.S. Arıkan, H. Külah, A normally closed electrostatic parylene microvalve for micro total analysis systems. Sens. Actuators A: Phys. 181, 81–86 (2012)10.1016/j.sna.2012.05.008 ↗
82. N. Pekas, Q. Zhang, D. Juncker, Electrostatic actuator with liquid metal–elastomer compliant electrodes used for on-chip microvalving. J. Micromech. Microeng. 22(9), 097001 (2012)10.1088/0960-1317/22/9/097001 ↗
83. S. Wagner, S. Bauer, Materials for stretchable electronics. MRS Bull. 37(03), 207–213 (2012)10.1557/mrs.2012.37 ↗
84. J.H. Kim, K.T. Lau, R. Shepherd, Y. Wu, G. Wallace, D. Diamond, Performance characteristics of a polypyrrole modified polydimethylsiloxane (PDMS) membrane based microfluidic pump. Sens. Actuators A: Phys. 148(1), 239–244 (2008)10.1016/j.sna.2008.07.029 ↗
85. J.J. Wang, T.H. Hsu, C.N. Yeh, J.W. Tsai, Y.C. Su, Piezoelectric polydimethylsiloxane films for MEMS transducers. J. Micromech. Microeng. 22(1), 015013 (2012)10.1088/0960-1317/22/1/015013 ↗
86. J.W. Tsai, J.J. Wang, Y.C. Su, Piezoelectric rubber films for autonomous physiological monitoring systems. Sens. Actuators A: Phys. 215, 176–183 (2014)10.1016/j.sna.2013.08.044 ↗
87. W. Hilber, S. Clara, B. Jakoby, Microfluidic pumping utilizing a PDMS membrane with an integrated nonuniform open-porous foam. IEEE Sens. J. 15(9), 5109–5114 (2015)10.1109/JSEN.2015.2438431 ↗
88. P.H. Huang, N. Nama, Z. Mao, P. Li, J. Rufo, Y. Chen, Y. Xie, C.H. Wei, L. Wang, T.J. Huang, A reliable and programmable acoustofluidic pump powered by oscillating sharp-edge structures. Lab Chip 14(22), 4319–4323 (2014)10.1039/C4LC00806E ↗
89. K. Oh, J.H. Chung, S. Devasia, J.J. Riley, Bio-mimetic silicone cilia for microfluidic manipulation. Lab chip 9(11), 1561–1566 (2009)10.1039/b817409a ↗
90. K. Oh, B. Smith, S. Devasia, J.J. Riley, J.H. Chung, Characterization of mixing performance for bio-mimetic silicone cilia. Microfluid. Nanofluid. 9(4–5), 645–655 (2010)10.1007/s10404-010-0578-3 ↗
91. T.R. Lee, K. Oh, J.H. Chung, Y.S. Chang, J.B. Choi, G. Yagawa, Y.J. Kim, Resonant behavior and microfluidic manipulation of silicone cilia due to an added mass effect. Soft Matter. 7(9), 4325–4334 (2011)10.1039/c0sm01294g ↗
92. H.B. Lee, K. Oh, W.H. Yeo, T.R. Lee, Y.S. Chang, J.B. Choi, K.H. Lee, J.H. Chung, Enhanced bioreaction efficiency of a microfluidic mixer toward high-throughput and low-cost bioassays. Microfluid. Nanofluid. 12(1–4), 143–156 (2012)
93. A. Rockenbach, V. Mikulich, C. Brücker, U. Schnakenberg, Fluid transport via pneumatically actuated waves on a ciliated wall. J. Micromech. Microeng. 25(12), 125009 (2015)10.1088/0960-1317/25/12/125009 ↗
94. B. Gorissen, M. de Volder, D. Reynaerts, Pneumatically-actuated artificial cilia array for biomimetic fluid propulsion. Lab Chip 15(22), 4348–4355 (2015)10.1039/C5LC00775E ↗
95. D. Snakenborg, H. Klank, J.P. Kutter, Polymer microvalve with pre-stressed membranes for tunable flow–pressure characteristics. Microfluid. Nanofluid. 10(2), 381–388 (2011)10.1007/s10404-010-0676-2 ↗
96. Y.N. Wang, C.H. Tsai, L.M. Fu, L.K.L. Liou, Microfluidic rectifier based on poly (dimethylsiloxane) membrane and its application to a micropump. Biomicrofluidics 7(4), 044118 (2013)10.1063/1.4818905 ↗
97. R. Mohan, B.R. Schudel, A.V. Desai, J.D. Yearsley, C.A. Apblett, P.J. Kenis, Design considerations for elastomeric normally closed microfluidic valves. Sens. Actuators B: Chem. 160(1), 1216–1223 (2011)10.1016/j.snb.2011.09.051 ↗
98. T. Mazzocchi, L. Ricotti, N. Pinzi, A. Menciassi, Parametric design, fabrication and validation of one-way polymeric valves for artificial sphincters. Sens. Actuators A: Phys. 233, 184–194 (2015)10.1016/j.sna.2015.07.005 ↗
99. M.E. Piyasena, R. Newby, T.J. Miller, B. Shapiro, E. Smela, Electroosmotically driven microfluidic actuators. Sens. Actuators B: Chem. 141(1), 263–269 (2009)10.1016/j.snb.2009.05.014 ↗
100. D. Sritharan, A.S. Chen, P. Aluthgama, B. Naved, E. Smela, Bubble-free electrokinetic flow with propylene carbonate. Electrophoresis 36(20), 2622–2629 (2015)10.1002/elps.201400443 ↗