journal article·2026-06Open access

In vitro and skin patch sensitivity testing of a carbon nanotube-based wearable fabric sodium sensor

Victoria Stege, Zachary Cheney, Madison Luthy, Ekin G. Simsar, Metin Uz, Ronald Otterstetter, Shelby Daniels, Ellen Ingle, Chelsea N. Monty

Abstract

Carbon nanotube (CNT)-based materials are currently being developed for use in human health monitoring due to their high electrical conductivity and sensitivity. However, the skin irritation potential and overall safety of CNTs have not been fully characterized when used in wearable sensor applications. In this study, in vitro and human patch testing were used to determine the skin irritation potential of a wearable CNT-based sweat sodium sensor which was created for commercial applications. Human 3T3 fibroblast cells were exposed to the constituent components of the sensor and cell viability was evaluated using a regular toxicity (MTT) assay. The obtained results showed no statistical difference between the relative cell viabilities of the control cells and the cells exposed to the sensor components using a one-way ANOVA (p > 0.05). A modified leaching test was performed and determined that a very low concentration of MWCNTs of 0.0867 µg/mL, or 0.05% of the initial MWCNT concentration, was leached from the sodium sensor under wet conditions that mimic sweating. The concentration was found to be below previously reported toxic levels for MWCNTs. Pilot-scale patch testing trials were performed on thirteen subjects at rest and on eleven subjects during exercise to further support the in vitro skin irritation test findings. During the patch and exercise testing trials, the participants experienced either no irritation or minimal irritation (p > 0.05). Combining the in vitro testing, modified dynamic leaching test, human patch testing, and exercise skin irritation testing results, it can be concluded that the sweat sodium sensor was not a skin irritant in this use case. Further testing will involve reconstructed human epidermis or a 3D in vitro skin model and subsequent human patch and exercise testing on a wider demographic of participants are needed to validate these findings.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Analytical Chemistry and Sensors · Smart Materials for Construction

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (36)

Show source-provided references
1. Allergic contact dermatitis to components of wearable adhesive health devices10.1097/DER.0000000000000575 ↗
2. Bio-acceptability of wearable sensors: a mechanistic study towards evaluating ionic leaching induced cellular inflammation10.1038/s41598-022-13810-0 ↗
3. Carbon nanotube wearable sensors for health diagnostics10.3390/s21175847 ↗
4. Physiology of sweat gland function: the roles of sweating and sweat composition in human health10.1080/23328940.2019.1632145 ↗
5. Realizing the potential of commercial E-textiles for wearable glucose biosensing application10.1021/acsmaterialsau.4c00033 ↗
6. Carbon nanotube wearable sensors for health diagnostics10.3390/s21175847 ↗
7. A wearable multisensing patch for continuous sweat monitoring10.1016/j.bios.2016.09.038 ↗
8. The role of sampling in wearable sweat sensors10.1016/j.talanta.2020.120801 ↗
9. Wearable and flexible electrochemical sensors for sweat analysis: a review10.1038/s41378-022-00443-6 ↗
10. Diving into sweat: advances, challenges, and future directions in wearable sweat sensing10.1021/acsnano.4c10344 ↗
11. Review of toxicity studies of carbon nanotubes10.1539/joh.17-0089-RA ↗
12. The effects of carbon nanotubes on lung and dermal cellular behaviors10.2217/nnm.14.42 ↗
13. An insight into the toxicological impacts of carbon nanotubes (CNTs) on human health: a review10.1016/j.envadv.2024.100601 ↗
14. Evaluation of the skin sensitization potential of carbon nanotubes using alternative in vitro and in vivo assays10.3390/toxics8040122 ↗
15. Evaluation of dermal and eye irritation and skin sensitization due to carbon nanotubes10.1016/j.yrtph.2011.08.007 ↗
16. Carcinogenicity evaluation for the application of carbon nanotubes as biomaterials in RasH2 mice10.1038/srep00498 ↗
17. Evaluation of CNT toxicity by comparison to tattoo ink10.1016/S1369-7021(11)70188-2 ↗
18. Safe clinical use of carbon nanotubes as innovative biomaterials10.1021/cr400341h ↗
19. First human trials of a dry electrophysiology sensor using a carbon nanotube array interface10.1016/j.sna.2008.03.007 ↗
20. Self-adhesive epidermal carbon nanotube electronics for tether-free long-term continuous recording of biosignals10.1038/srep06074 ↗
21. Application of a 4‐h human patch test method for comparative and investigative assessment of skin irritation10.1111/j.1600-0536.1998.tb05706.x ↗
22. Comparative assessment of 24-Hr primary skin irritation test and human patch test data with in vitro skin irritation tests according to OECD test guideline 439 (for Quasi-Drugs in Japan)10.2131/jts.43.751 ↗
23. International Organization for Standardization. ISO 10993–23:2021/Amd 1:2025 Biological Evaluation of Medical Devices — Part 23: Tests for Irritation, 1st ed.; 2025.
24. Assessment of the dermal and ocular irritation potential of multi-walled carbon nanotubes by using in vitro and in vivo methods10.1016/j.toxlet.2009.09.007 ↗
25. The role of fibroblasts in skin homeostasis and repair10.3390/biomedicines12071586 ↗
26. Evaluation of a wearable fabric-based sensor for accurate sodium determination in sweat during exercise10.1007/s00421-023-05364-4 ↗
27. Platinum electrode functionalized with Calix[4]Arene thin films for impedimetric detection of sodium ions10.1016/S0928-4931(02)00057-7 ↗
28. Electrochemistry of calixarene and its analytical applications
29. Ion sensor for the quantification of sodium in sweat samples10.1109/JSEN.2013.2257168 ↗
30. Electroconductive Nylon-6/multi-walled carbon nanotube nanocomposite for sodium sensing applications10.1016/j.jcomc.2021.100116 ↗
31. Detection and quantification of free carbon nanotubes in abraded polymer nanocomposites using UV–Vis spectroscopy10.1016/j.impact.2019.100190 ↗
32. About estimating the limit of detection by the signal to noise approach10.4172/2153-2435.1000355 ↗
33. International Organization for Standardization. ISO 10993–5 Biological Evaluation of Medical Devices Part 5: Tests for In Vitro Cytotoxicity. 2009, 1–42.
34. International Organization for Standardization. ISO 10993–10 Biological Evaluation of Medical Devices Part 10: Tests for Skin Sensitization. 2021, pp 1–56.
35. Racial differences in allergic sensitization: recent findings and future directions10.1007/s11882-013-0343-2 ↗
36. Ethnic differences in objective and subjective skin irritation response: an international study10.1111/srt.12111 ↗