journal article·2022-03

Recent advancement in electrode materials and fabrication, microfluidic designs, and self-powered systems for wearable non-invasive electrochemical glucose monitoring

Alireza Sanati, Yasaman Esmaeili, Elham Bidram, Laleh Shariati, Mohammad Rafienia, Sara Mahshid, Onur Parlak

Publisher page

Abstract

No abstract is available for this record. The assistant can identify its topic from the title, but cannot infer the study’s results.

Source: Not provided · Quality: missing

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Advanced Sensor and Energy Harvesting Materials · Conducting polymers and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (100+)

Show source-provided references
1. Continuous glucose monitoring systems-current status and future perspectives of the flagship technologies in biosensor research10.1016/j.bios.2021.113054 ↗
2. Maximizing the success rate of minimal model insulin sensitivity measurement in humans: the importance of basal glucose levels10.1042/cs1010001 ↗
3. Brief report: comparison of continuous glucose monitoring and finger-prick blood glucose levels in hospitalized patients administered basal-bolus insulin10.1089/dia.2012.0282 ↗
4. Clinical evaluation of the GlucoWatch® biographer: a continual, non-invasive glucose monitor for patients with diabetes10.1016/S0956-5663(01)00189-0 ↗
5. In vivo microscopic photoacoustic spectroscopy for non-invasive glucose monitoring invulnerable to skin secretion products10.1038/s41598-018-19340-y ↗
6. Effects of daily glucose fluctuations on the healing response to everolimus-eluting stent implantation as assessed using continuous glucose monitoring and optical coherence tomography10.1186/s12933-016-0395-4 ↗
7. Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy10.1016/j.bspc.2015.01.005 ↗
8. Non-invasive continuous-time glucose monitoring system using a chipless printable sensor based on split ring microwave resonators10.1038/s41598-020-69547-1 ↗
9. Ultrasound-modulated optical glucose sensing using a 1645nm laser
10. A comparison study of macrocyclic hosts functionalized reduced graphene oxide for electrochemical recognition of tadalafil10.1016/j.bios.2016.07.016 ↗
11. Evaluation of a near-infrared light ultrasound system as a non-invasive blood glucose monitoring device10.1111/dom.13914 ↗
12. A morphology-based ultrasensitive multicolor colorimetric assay for detection of blood glucose by enzymatic etching of plasmonic gold nanobipyramids10.1016/j.aca.2019.04.053 ↗
13. The woven fiber organic electrochemical transistors based on polypyrrole nanowires/reduced graphene oxide composites for glucose sensing10.1016/j.bios.2017.04.018 ↗
14. Wearable sweat sensors10.1038/s41928-018-0043-y ↗
15. Salivary diagnostics on paper microfluidic devices and their use as wearable sensors for glucose monitoring10.1007/s00216-019-01788-0 ↗
16. Wearable continuous glucose monitoring sensors: a revolution in diabetes treatment10.3390/electronics6030065 ↗
17. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring10.1126/sciadv.1701629 ↗
18. Wearable contact lens biosensors for continuous glucose monitoring using smartphones10.1021/acsnano.8b00829 ↗
19. Laser-inscribed contact lens sensors for the detection of analytes in the tear fluid10.1016/j.snb.2020.128183 ↗
20. Ultrasound-modulated optical glucose sensing using a 1645nm laser10.1038/s41598-020-70305-6 ↗
21. Microfluidic chip-based wearable colorimetric sensor for simple and facile detection of sweat glucose10.1021/acs.analchem.9b03110 ↗
22. Template-directed hierarchical self-assembly of graphene based hybrid structure for electrochemical biosensing10.1016/j.bios.2013.04.004 ↗
23. Highly sensitive electrochemical hydrogen peroxide sensor based on iron oxide-reduced graphene oxide-chitosan modified with DNA-Celestine blue10.1002/elan.201600660 ↗
24. On/Off-switchable zipper-like bioelectronics on a graphene interface10.1002/adma.201303075 ↗
25. Wearable organic electrochemical transistor patch for multiplexed sensing of calcium and ammonium ions from human perspiration
26. Novel glucose-responsive of the transparent nanofiber hydrogel patches as a wearable biosensor via electrospinning10.1038/s41598-020-75906-9 ↗
27. A flexible non-enzymatic glucose sensor based on copper nanoparticles anchored on laser-induced graphene10.1016/j.carbon.2019.10.006 ↗
28. Electrochemical sensors based on metal oxide-boron nitride nanocomposites in the detection of biomolecules and toxic chemicals
29. Magnetic nanoparticles in biomedical applications: a review10.1016/j.apsadv.2021.100163 ↗
30. Combining 3D printing and screen-printing in miniaturized, disposable sensors with carbon paste electrodes10.1039/D1TC01557E ↗
31. Nonenzymatic electrochemical sensors via Cu native oxides (CuNOx) for sweat glucose monitoring
32. Highly sensitive glucose sensor based on hierarchical CuO10.1007/s11431-020-1718-4 ↗
33. A non-enzymatic glucose sensor enabled by bioelectronic pH control10.1038/s41598-019-46302-9 ↗
34. Nanostructured nickel oxide electrodes for non-enzymatic electrochemical glucose sensing10.1007/s00604-020-4171-5 ↗
35. A Review on metal- and metal oxide-based nanozymes: properties, mechanisms, and applications10.1007/s40820-021-00674-8 ↗
36. Metal–organic framework as a compartmentalized integrated nanozyme reactor to enable high-performance cascade reactions for glucose detection10.1021/acssuschemeng.0c06325 ↗
37. Tattoo-based noninvasive glucose monitoring: a proof-of-concept study10.1021/ac504300n ↗
38. Clinical evidence for use of a noninvasive biosensor for tear glucose as an alternative to painful finger-prick for diabetes management utilizing a biopolymer coating10.1021/acs.biomac.8b01429 ↗
39. Pacifier Biosensor: Toward noninvasive saliva biomarker monitoring10.1021/acs.analchem.9b03379 ↗
40. A fully integrated and self-powered smartwatch for continuous sweat glucose monitoring10.1021/acssensors.9b00891 ↗
41. Mouthguard biosensor with telemetry system for monitoring of saliva glucose: a novel cavitas sensor10.1016/j.bios.2015.12.014 ↗
42. Eyeglasses-based tear biosensing system: non-invasive detection of alcohol, vitamins and glucose10.1016/j.bios.2019.04.058 ↗
43. Wearable multiplexed biosensor system toward continuous monitoring of metabolites10.1016/j.bios.2020.112038 ↗
44. Sustainable and high-power wearable glucose biofuel cell using long-term and high-speed flow in sportswear fabrics10.1016/j.bios.2020.112652 ↗
45. A highly integrated sensing paper for wearable electrochemical sweat analysis10.1016/j.bios.2020.112828 ↗
46. A wearable self-powered biosensor system integrated with diaper for detecting the urine glucose of diabetic patients10.1016/j.snb.2021.130046 ↗
47. Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics10.1038/ncomms14997 ↗
48. Simultaneous monitoring of sweat and interstitial fluid using a single wearable biosensor platform10.1002/advs.201800880 ↗
49. Portable and wearable real-time stress monitoring: a critical review
50. A wearable electrochemical glucose sensor based on simple and low-cost fabrication supported micro-patterned reduced graphene oxide nanocomposite electrode on flexible substrate10.1016/j.bios.2018.02.054 ↗
51. Synthesis of wearable and flexible NiP0.1-SnOx/PANI/CuO/cotton towards a non-enzymatic glucose sensor10.1016/j.bios.2019.04.010 ↗
52. A comparative study of non-enzymatic glucose detection in artificial human urine and human urine specimens by using mesoporous bimetallic cobalt-iron supported N-doped graphene biosensor based on differential pulse voltammetry10.1016/j.snb.2019.02.018 ↗
53. Yangyue, Non-enzymatic glucose sensor based on ZnO–CeO2 whiskers10.1016/j.matchemphys.2019.122051 ↗
54. Highly sensitive voltammetric glucose biosensor based on glucose oxidase encapsulated in a chitosan/kappa-carrageenan/gold nanoparticle bionanocomposite10.3390/s19010154 ↗
55. Pulse-voltammetric glucose detection at gold junction electrodes10.1021/ac101303s ↗
56. A simple, cost-effective and selective analysis of glucose via electrochemical impedance sensing based on copper and nitrogen co-doped carbon quantum dots10.1039/D0NJ01754J ↗
57. Mediator-free electron-transfer on patternable hierarchical meso/macro porous bienzyme interface for highly-sensitive sweat glucose and surface electromyography monitoring10.1016/j.snb.2020.127962 ↗
58. Biocompatible enzymatic roller pens for direct writing of biocatalytic materials: do-it-yourself10.1002/adhm.201400808 ↗
59. Electrochemical glucose biosensors10.1021/cr068123a ↗
60. Biosensors: sense and sensibility10.1039/c3cs35528d ↗
61. Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)10.1039/D0CS00304B ↗
62. Amperometric glucose sensor with ferrocene as an electron transfer mediator10.1016/0956-5663(92)87018-K ↗
63. Ferrocene-mediated enzyme electrode for amperometric determination of glucose10.1021/ac00268a018 ↗
64. Strong Interaction between imidazolium-based polycationic polymer and ferricyanide: toward redox potential regulation for selective in vivo electrochemical measurements10.1021/ac202748s ↗
65. Preparation, characterization and application of alkanethiol self-assembled monolayers modified with tetrathiafulvalene and glucose oxidase at a gold disk electrode10.1016/S0022-0728(02)00753-2 ↗
66. Theoretical treatment of diffusion and kinetics of osmium redox polymer mediated glucose oxidase enzyme electrodes: analytical expression of current density for varying potential10.1016/j.electacta.2017.01.149 ↗
67. Effect of individual plasma components on the performance of a glucose enzyme electrode based on redox polymer mediation of a flavin adenine dinucleotide-dependent glucose dehydrogenase10.1016/j.electacta.2019.02.039 ↗
68. Organic electronics for point-of-care metabolite monitoring10.1016/j.tibtech.2017.10.022 ↗
69. Wiring of glucose oxidase with graphene nanoribbons: an electrochemical third generation glucose biosensor10.1007/s00604-017-2115-5 ↗
70. Third-generation electrochemical biosensor based on nitric oxide reductase immobilized in a multiwalled carbon nanotubes/1-n-butyl-3-methylimidazolium tetrafluoroborate nanocomposite for nitric oxide detection10.1016/j.snb.2019.01.074 ↗
71. Structuring Au nanoparticles on two-dimensional MoS2 nanosheets for electrochemical glucose biosensors10.1016/j.bios.2016.03.024 ↗
72. Third-generation glucose biosensor incorporated in a conducting printing ink10.1016/0925-4005(94)87077-2 ↗
73. Fabrication of a third-generation glucose biosensor using graphene-polyethyleneimine-gold nanoparticles hybrid10.1016/j.snb.2016.03.147 ↗
74. Reagentless glucose biosensor based on the direct electrochemistry of glucose oxidase on carbon nanotube-modified electrodes10.1002/elan.200603513 ↗
75. Three-dimensional porous MXene/NiCo-LDH composite for high performance non-enzymatic glucose sensor10.1016/j.apsusc.2019.143554 ↗
76. Highly electrocatalytic, durable, and stretchable nanohybrid fiber for on-body sweat glucose detection10.1021/acsami.8b20583 ↗
77. Chemical design of nanozymes for biomedical applications10.1016/j.actbio.2021.02.036 ↗
78. Wearable wireless tyrosinase bandage and microneedle sensors: toward melanoma screening10.1002/adhm.201701264 ↗
79. Eyeglasses based wireless electrolyte and metabolite sensor platform10.1039/C7LC00192D ↗
80. Flexible plastic, paper and textile lab-on-a chip platforms for electrochemical biosensing10.1039/C8LC00025E ↗
81. A novel laccase biosensor based on laccase immobilized graphene-cellulose microfiber composite modified screen-printed carbon electrode for sensitive determination of catechol10.1038/srep41214 ↗
82. Toward transparent nanocomposites based on polystyrene matrix and PMMA-grafted CeO2 nanoparticles10.1021/am200983h ↗
83. Investigation of the corrosion behavior of cathodic arc evaporated stainless steel coating in 3.5% NaCl, Protection of Metals and
84. A wearable cellulose acetate-coated mouthguard biosensor for in vivo salivary glucose measurement10.1021/acs.analchem.0c01201 ↗
85. Noninvasive alcohol monitoring using a wearable tattoo-based iontophoretic-biosensing system10.1021/acssensors.6b00356 ↗
86. Epidermal enzymatic biosensor for sweat vitamin C: towards personalized nutrition10.1021/acssensors.0c00604 ↗
87. Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics10.1016/j.bios.2015.07.039 ↗
88. Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites10.1039/C3AN02359A ↗
89. Novartis signs up for Google smart lens10.1038/nbt0914-856 ↗
90. A multifunctional smart soft contact lens device enabled by nanopore thin film for glaucoma diagnostics and in situ drug delivery10.1109/JMEMS.2019.2927232 ↗
91. Electrospun nanofibers for regenerative medicine10.1002/adhm.201100021 ↗
92. Potential of an electrospun composite scaffold of poly (3-hydroxybutyrate)-chitosan/alumina nanowires in bone tissue engineering applications10.1016/j.msec.2019.02.062 ↗
93. Novel electrospun nanofibers of modified gelatin-tyrosine in cartilage tissue engineering10.1016/j.msec.2016.10.003 ↗
94. Glucose-responsive poly(vinyl alcohol)/b-cyclodextrin hydrogel with glucose oxidase immobilization10.1007/s10853-019-03805-0 ↗
95. A cellulose/b-cyclodextrin nanofiber patch as a wearable epidermal glucose sensor10.1039/C9RA03887F ↗
96. Fully stretchable capillary microfluidics-integrated nanoporous gold electrochemical sensor for wearable continuous glucose monitoring10.1021/acsami.9b00848 ↗
97. A novel 3D paper-based microfluidic electrochemical glucose biosensor based on rGO-TEPA/PB sensitive film10.1016/j.aca.2019.10.049 ↗
98. Porous enzymatic membrane for nanotextured glucose sweat sensors with high stability toward reliable noninvasive health monitoring10.1002/adfm.201902521 ↗
99. 3D-printed sugar scaffold for high-precision and highly sensitive active and passive wearable sensors10.1002/advs.201902521 ↗
100. Development of graphene oxide/polyaniline Inks for high performance flexible microsupercapacitors via extrusion printing10.1002/adfm.201870142 ↗