Measuring Human Body Temperature through Temperature Sensing Fabric
Source abstract
Abstract
Continuous measurement of temperature profiles on the surface of the human body offers various kinds of information valuable for clinical diagnosis and as a useful guide to take suitable action. In this article, the behavior of a newly developed temperature sensing fabric (TSF) over extended periods of time in a practical application and its comparison with a reference temperature sensor was investigated. The performance of the TSF was analyzed by measuring the human body skin temperature under steady-state and dynamic conditions. A dedicated interface was built in the LabVIEW environment to measure and record the temperature readings of the TSF and reference temperature sensor simultaneously. The reference and TSF sensors both followed exactly the same trends and experienced the same type of movement artifacts.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
University of Manchester and NED University of Engineering and Technology
Istanbul Technical University and Harvard University
University of Manchester and National Textile University
University of Manchester
References (47)
Show source-provided references
1. 10.1109/JSEN.2014.237094510.1109/JSEN.2014.2370945 ↗
2. Lina M.C. · Smart Materials and Structures · 2014 · 23 · 5500110.1088/0964-1726/23/5/055001 ↗
3. Lam Po Tang, S. · Transactions of the Institute of Measurement and Control · 2007 · 29 · 28310.1177/0142331207070389 ↗
4. Funnell R., Koutoukidis G., Lawrence K. Tabbner's Nursing Care: Theory and Practice; Churchill Livingstone: Australia, 2009; pp 251–274.
5. Parsons K. · 2003 · 31
6. 10.1542/pir.28.7.24910.1542/pir.28.7.249 ↗
7. 10.1109/51.68795910.1109/51.687959 ↗
8. 10.4065/78.5.60310.4065/78.5.603 ↗
9. 10.1088/0143-0815/6/2/00110.1088/0143-0815/6/2/001 ↗
10. 10.1109/51.68796010.1109/51.687960 ↗
11. 10.1007/s00520-009-0627-110.1007/s00520-009-0627-1 ↗
12. Sung M., DeVaul R., Jimenez S., Gips J., Pentland A. Shiver Motion and Core Body Temperature Classification for Wearable Soldier Health Monitoring Systems. In Proceedings of the IEEE Eighth International Symposium on Wearable Computers (ISWC 2004), 2004.
13. ISO 9886 Ergonomics—Evaluation of thermal strain by physiological measurements, 2004.
14. 10.1016/j.physbeh.2006.04.02610.1016/j.physbeh.2006.04.026 ↗
15. Oliveira A., Gehin C., Delhomme G., Dittmar A., McAdams E. In Thermal Parameters Measurement on Fire Fighter During Intense Fire Exposition, Engineering in Medicine and Biology Society, 2009, Annual International Conference of the IEEE, 3–6 Sept. 2009; pp 4128–4131.10.1109/IEMBS.2009.5332698 ↗
16. 10.1109/IMTC.2008.454717310.1109/IMTC.2008.4547173 ↗
17. 10.1016/j.sna.2014.10.03010.1016/j.sna.2014.10.030 ↗
18. 10.1016/j.sna.2014.09.02810.1016/j.sna.2014.09.028 ↗
19. 10.3390/s13081111410.3390/s130811114 ↗
20. 10.1016/j.sna.2007.10.07110.1016/j.sna.2007.10.071 ↗
21. Cheng M.H., Chen L.C., Ying-Che H., Chang Ming Y., Tzu Lin Y. In A Real-Time Heart-Rate Estimator from Steel Textile ECG Sensors in a Wireless Vital Wearing System, Bioinformatics and Biomedical Engineering, The 2nd International Conference on on Bioinformatics and Biomedical Engineering, May 16–18, 2008, Shanghai. China, pp 1339–1342.10.1109/ICBBE.2008.664 ↗
22. 10.1109/ISIE.2007.437506210.1109/ISIE.2007.4375062 ↗
23. 10.1016/j.sna.2003.10.07110.1016/j.sna.2003.10.071 ↗
24. 10.1177/152808371243806910.1177/1528083712438069 ↗
25. 10.1109/IEMBS.2008.464919810.1109/IEMBS.2008.4649198 ↗
26. Derchak P.A. · 2004
27. 10.1109/IEMBS.2004.140391910.1109/IEMBS.2004.1403919 ↗
28. 10.1016/j.medengphy.2007.05.01410.1016/j.medengphy.2007.05.014 ↗
29. Ziegler S. · Fibres & Textiles in Eastern Europe · 2010 · 17 · 84
30. 10.1016/j.mseb.2009.07.01410.1016/j.mseb.2009.07.014 ↗
31. 10.1016/S0928-4931(98)00069-110.1016/S0928-4931(98)00069-1 ↗
32. Locher I. · 2004
33. Locher I. · 2005
34. 10.3390/s10090793410.3390/s100907934 ↗
35. 10.1177/152808371349524910.1177/1528083713495249 ↗
36. 10.3390/fib101000210.3390/fib1010002 ↗
37. 10.17265/2159-5313/2016.09.00310.17265/2159-5313/2016.09.003 ↗
38. Husain M.D. · International Journal of Textile Science · 2013 · 2 · 105
39. Omega Surface-Mount RTD Advanced-Design: Class A Accuracy. http://www.omega.com/pptst/SA1-RTD.html (accessed November 2015).
40. PicoTech PT-104 Platinum Resistance Data Logger. https://www.picotech.com/data-logger/pt-104/pt-104-specifications (accessed November 2015).
41. Agilent Technologies Agilent 34401A Multimeter - Product Overview. http://cp.literature.agilent.com/litweb/pdf/5968-0162EN.pdf (accessed November 2015).
42. Kobayashi T., Oi S., Sato M., Isogai Y., Furuich K., Ishimaru S., Nonomura C., Tanaka M. Analysis of Clothing Pressure on the Human Body. In SIMULIA Customer Conference, 2011.
43. Hyewon S. · 2007
44. Michalski L. · 2002 · 333
45. Michalski L. · 2002 · 85
46. Parsons K. · 2003 · 1
47. 10.1109/MWSYM.2008.463322910.1109/MWSYM.2008.4633229 ↗