journal article·2007-11-22

Fire Retardancy of Natural Fibre Reinforced Sheet Moulding Compound

T. D. Hapuarachchi, G. Ren, M. Fan, P. J. Hogg, T. Peijs

Applied Composite Materials· Volume 14· Issue 4
Publisher page

Abstract

Due to environmental awareness and economical considerations, natural fibre reinforced polymer composites seem to present a viable alternative to synthetic fibre reinforced polymer composites such as glass fibres. This is a feasibility study to asses the potential application of natural fibre reinforced sheet moulding compound materials (NF-SMC) for the use in building applications, with particular emphases to their reaction to fire. The reinforcing fibres in this study were industrial hemp fibres. The cone calorimeter which asses the fire hazard of materials by Heat Release Rate (HRR) was used, radiant heat fluxes of 25 and 50 kW/m2 were utilised to simulate an ignition source and fully developed room fire conditions respectively. The results acquired here demonstrate that the NF-SMC can compete with current building materials in terms of their fire behaviour. The peak heat release value for the fire retardant (FR) NF-SMC was 176 kW/m2 conversely for a non-FR NF-SMC was 361 kW/m2. © 2007 Springer Science+Business Media B.V.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Natural Fiber Reinforced Composites · Flame retardant materials and properties · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. Garkhail, S.K., Heijenrath, R.W.H., Peijs, T.: Mechanical properties of natural-fibre-mat-reinforced thermoplastics based on flax fibres and polypropylene. Appl. Compos. Mater. 7, 5–6 (2000)10.1023/A:1026590124038 ↗
2. Mohanty, K., Misraa, M., Hinrichsen, G.: Biofibres, biodegradable polymers and biocomposites. An overview. Macromol. Mater. Eng. 276/277, 1–24 (2000)10.1002/(SICI)1439-2054(20000301)276:1<1::AID-MAME1>3.0.CO;2-W ↗
3. Joshia, S.V., Drzal, L.T., Mohanty, K., Arora, S.: Are natural fiber composites environmentally superior to glass fiber reinforced composites? Composites: Part A 35, 371–376 (2004)10.1016/j.compositesa.2003.09.016 ↗
4. Schneider, J.P., Myers, G.E., Clemons, C.M., English, B.W.: Biofibers as reinforcing fillers in thermoplastic composites. J. Vinyl. Addit. Technol. 1(2), 103–108 (1995)10.1002/vnl.730010212.n ↗
5. Peijs, T.: Composites turn green, e-Polymers, no. T_002 (2002)
6. Babrauskas, V.: Development of the Cone Calorimeter, A Bench-Scale Heat Release Rate Apparatus Based on Oxygen Consumption (NBSIR 82-2611). [U.S.] Natl. Bur. Stand. (1982)10.6028/NBS.IR.82-2611 ↗
7. Schartel, B. (ed) and Braun U.: Fourteenth Annual BCC Conference on Flame Retardancey, Fire Retarded Polypropylene/Flax Biocomposites, pp 219–228. August (2003)
8. Malgorzata, H., Paukszta, D.: Flammability of composites based on polypropylene and flax fibres. Mol. Cryst. Liq. Cryst. 354, 373–380 (2000)10.1080/10587250008023629 ↗
9. Sain, M., Park, S.H., Suhara, F., Law, S.: Flame retardant and mechanical properties of natural fibre-PP composites containing magnesium hydroxide. Polym. Degrad. Stab. 83, 363–367 (2004)10.1016/S0141-3910(03)00280-5 ↗
10. ASTM E-1354; Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using the Oxygen Consumption Calorimeter. The American Society for Testing and Materials, 1992
11. Karlsson, B.: Modeling fire growth on combustible lining materials in enclosures. Report TVBB-1009, Lund University, Lund, Sweden (1992)
12. Hakkarainen, T., Kokkala, M.: Application of a one-dimensional thermal flame spread model on predicting the rate of heat release in the SBI test. Fire Mater. 25, 61–70 (2001)10.1002/fam.760 ↗
13. Brown, J.E., Braun, E., Twilley, W.H.: Cone calorimetric evaluation of the flammability of composite materials. Report NBSIR 88–3733 (1988)10.6028/NBS.IR.88-3733 ↗
14. Scudamore, M.J.: Fire performance studies on glass reinforced plastic laminates. Fire Mater. 18, 323–325 (1994)10.1002/fam.810180507 ↗
15. Madorsky, S.L.: Thermal degradation of organic polymers. Tex. Res. J. 35, 289–290 (1965)10.1177/004051756503500318 ↗
16. Davies, J.M., Hakmi, R., Wang, H.-B.: Numerical temperature analysis of hygroscopic panels exposed to fire. In: Proceedings of eighth international conference on numerical methods in thermal problems. Swansea (1993)
17. Roberts, A.F.: Problems associated with the theoretical analysis of the burning of wood. In: 13th international symposium on combustion, pp. 893–903. The Combustion Institute, Pittsburgh. (1971)10.1016/S0082-0784(71)80090-5 ↗