Abstract
Hemodialysis (HD) is widely considered to be the primary means of kidney replacement therapy for end-stage renal disease, involving millions of patients worldwide. The utilization of continuous non-invasive sensors for blood property detection can achieve an adequacy assessment of the dialysis process, which is of great significance for determining the optimal treatment time, ensuring the treatment effect, and improving the quality of life of patients. In this work, a microwave metamaterial sensor is reported for HD based on spoof localized surface plasmons (LSPs). The spoof LSPs sensor is fabricated from a 21 × 12 × 0.043 mm3 thin film, which is conformally attached to the exterior of the pipeline in the dialysis circuit. This attachment design allows for continuous, non-invasive monitoring of variations in the blood’s permittivity of patients. The proposed sensor design is compatible with standard flexible printed circuit technology, allowing for low-cost and large-scale manufacturing. In the frequency range of 3–6 GHz, three resonance modes based on spoof LSPs can be used for liquid sensing with a maximum sensitivity of 0.39%. This study is expected to foster research and application of microwave metamaterial sensors in the biomedical field.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Plasmonic and Surface Plasmon Research · Gold and Silver Nanoparticles Synthesis and Applications · Advanced biosensing and bioanalysis techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Laboratory of Information Photonics and Optical Communications, School of Science, Beijing University of Posts and Telecommunications , Beijing 100876,
Funding
National Natural Science Foundation of China · Beijing Natural Science Foundation · Teaching Reform Projects at BUPT · BUPT Excellent Ph.D. Students Foundation · fund of state key laboratory of IPOC
References (46)
Show source-provided references
1. The major global burden of chronic kidney disease10.1016/S2214-109X(24)00050-0 ↗
2. Chronic kidney disease and the global public health agenda: An international consensus10.1038/s41581-024-00820-6 ↗
3. Chronic kidney disease10.1016/s0140-6736(21)00519-5 ↗
4. Examinations of effects of socio-demographic features and disease-related data of patients with hemodialysis on the quality of life10.1038/s41598-023-43473-4 ↗
5. Epidemiology of end-stage kidney disease10.1053/j.semvascsurg.2021.02.010 ↗
6. Serum adropin levels in patients on hemodialysis10.3390/life11040337 ↗
7. The current and future landscape of dialysis10.1038/s41581-020-0315-4 ↗
8. Portable, wearable and implantable artificial kidney systems: Needs, opportunities and challenges10.1038/s41581-023-00726-9 ↗
9. Epidemiology of haemodialysis outcomes10.1038/s41581-022-00542-7 ↗
10. A new method for continuous relative blood volume and Plasma sodium concentration estimation during hemodialysis10.1109/tbme.2019.2903134 ↗
11. A graphenic biosensor for real-time monitoring of urea during dialysis10.1109/jsen.2020.2966456 ↗
12. Incremental and personalized hemodialysis start: A new standard of care10.1016/j.ekir.2022.02.010 ↗
13. Three-wavelength optoelectronic system for hemodialysis monitoring10.1088/1742-6596/1400/6/066043 ↗
14. An optical technique for real-time monitoring of hemolysis during hemodialysis10.1109/tim.2015.2490939 ↗
15. A differential optical sensor for non-invasive real-time monitoring of ultrafiltration rate in hemofiltration therapies10.1109/jsen.2018.2865493 ↗
16. Optoelectronic online monitoring system for hemodialysis and its data analysis10.1016/j.snb.2022.131859 ↗
17. In vivo transdermal multi-ion monitoring with a potentiometric microneedle-based sensor patch10.1021/acssensors.2c01907 ↗
18. Evaluation of a wearable biosensor to monitor potassium imbalance in patients receiving hemodialysis10.1016/j.sbsr.2023.100561 ↗
19. Optical monitoring of hemodialysis using noninvasive measurement of uric acid in the dialysate10.1038/s41598-023-40335-x ↗
20. Capacitance-based biosensor for the measurement of total loss of l-amino acids in human serum during hemodialysis10.1021/acssensors.2c01342 ↗
21. Monitoring water content of blood during hemodialysis based on complex permittivity measurement10.1109/jsen.2020.2978220 ↗
22. Localized surface plasmons on textiles for non-contact vital sign sensing10.1109/tap.2022.3177529 ↗
23. Multiple spoof plasmonically induced transparency for sensing applications10.1103/physrevapplied.18.024035 ↗
24. Low-power, ultrafast, and dynamic all-optical tunable plasmon induced transparency in two stub resonators side-coupled with a plasmonic waveguide system10.1088/1361-6463/aa8d61 ↗
25. Dynamically tunable multiple plasmon-induced transparency effect based on monolayer graphene structure system with rectangular defect cavities10.1088/1402-4896/ad0d5e ↗
26. Spoof localized surface plasmons for sensing applications10.1002/admt.202000863 ↗
27. Localized spoof surface plasmons based on closed subwavelength high contrast gratings: Concept and microwave-regime realizations10.1038/srep27158 ↗
28. Dual circular complementary split ring resonator based metamaterial sensor with high sensitivity and quality factor for textile material detection10.1063/5.0196472 ↗
29. Realization of broadband terahertz metamaterial absorber using an anti-symmetric resonator consisting of two mutually perpendicular metallic strips10.1063/5.0092958 ↗
30. Mimicking surface plasmons with structured surfaces10.1126/science.1098999 ↗
31. Ultrathin plasmonic metamaterial for spoof localized surface plasmons10.1002/lpor.201300144 ↗
32. Terahertz spoof surface plasmon sensing based on dielectric metagrating coupling10.1063/5.0048491 ↗
33. A metamaterial sensor for detecting the location of a sub-wavelength object10.1063/5.0090146 ↗
34. High-FoM resonance in single hybrid plasmonic resonator via electromagnetic modal interference10.1109/tap.2020.2970037 ↗
35. A wireless non-metallic pipeline liquid level sensor based on spoof surface plasmon polaritons10.1109/JSEN.2024.3354896 ↗
36. Detection of defects in film-coated metals and non-metallic materials based on spoof surface plasmon polaritons10.1109/jsen.2019.2938816 ↗
37. Miniaturized microwave microfluidic sensor based on quarter-mode 2.5-D spoof plasmons10.1016/j.sna.2022.113621 ↗
38. The EBG-based biosensor for setting the appropriate dialysis time in hemodialysis process10.1109/jsen.2023.3289999 ↗
39. Measurement and hemodialysis effect of complex relative permittivity for blood of kidney patients using open-ended coaxial measurement probe10.1541/ieejeiss.131.2046 ↗
40. Localized spoof surface plasmons in textured open metal surfaces10.1364/ol.41.002181 ↗
41. Detection of defects in non-metallic composite material based on electronically controlled spoof surface plasmon polaritons10.1109/jsen.2020.3025457 ↗
42. High-sensitivity microfluidic sensor based on quarter-mode interdigitated spoof plasmons10.1109/jsen.2022.3218298 ↗
43. Ultra-high resolution sensing of glucose concentration based on amplified half-integer localized surface plasmons mode10.1088/1361-6463/ab5b4f ↗
44. Passive matched mushroom structure for a high sensitivity low profile antenna-based material detection system10.1109/JSEN.2019.2908687 ↗
45. Dual-sensing and dual-frequency microwave SRR sensor for liquid samples permittivity detection10.1016/j.measurement.2020.107805 ↗
46. A flexible wireless dielectric sensor for noninvasive fluid monitoring10.3390/s20010174 ↗