journal article·2024-07-01Open access

Impact of Durable Water-Repellent Finishing in Thermal Liner on Firefighter Heat Stress

Huipu Gao, Anthoney Shawn Deaton, Roger Barker

AATCC Journal of Research· Volume 11· Issue 4

Abstract

Heat stress has always been a critical issue among firefighters. Previous studies have indicated the potential influence of water-repellent finishing on heat release properties of clothing. Nevertheless, the impact of durable water repellent in a thermal liner on firefighter heat stress has never been studied. In this work, the impact of durable water-repellent finishing inside the thermal liner on heat stress has been evaluated systematically for the first time, using a sweat-guarded hotplate, a sweating manikin, and a physiological manikin. The results showed that there was no significant difference in heat loss capabilities on the fabric level or garment level between turnout clothing with or without durable water-repellent finishing in the thermal liner. In addition, no significant differences were identified in predicted physiological responses when tested in a mild environment. However, the turnout clothing with durable water-repellent finishing in the thermal liner demonstrated significantly less weight gain after the physiological manikin test. This initial investigation lays the groundwork for understanding how durable water-repellent finishing in thermal liners may impact firefighter comfort. It acts as a starting point for further research on the potential impact of durable water-repellent finishing on thermal protection and overall comfort under various ambient conditions.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Icing and De-icing Technologies · Winter Sports Injuries and Performance · Aerodynamics and Fluid Dynamics Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Textile Development and Marketing Department, Fashion Institute of Technology, New York, NY, USA

Textile Protection and Comfort Center, North Carolina State University, Raleigh, NC, USA

Funding

Federal Emergency Management Agency

References (47)

Show source-provided references
1. 10.1201/9780429444876-210.1201/9780429444876-2 ↗
2. 10.1080/10803548.2022.205874610.1080/10803548.2022.2058746 ↗
3. Smith D, Horn G, Goldstein E, et al. Firefighter fatalities and injuries: The role of heat stress and PPE. Report, Illinois Fire Service Institute, University of Illinois Urbana-Champaign, Champaign, IL, 2008.
4. Gao H · Text Res J · 2022 · 92 · 416310.1177/00405175221099947 ↗
5. 10.1177/0040517521102653710.1177/00405175211026537 ↗
6. 10.1177/0887302X1875734810.1177/0887302X18757348 ↗
7. 10.1016/B978-0-08-101212-3.00004-610.1016/B978-0-08-101212-3.00004-6 ↗
8. 10.1016/j.envint.2016.02.03510.1016/j.envint.2016.02.035 ↗
9. 10.1021/acs.est.1c0787610.1021/acs.est.1c07876 ↗
10. 10.3389/fmats.2023.114341110.3389/fmats.2023.1143411 ↗
11. 10.1177/1528083723120503210.1177/15280837231205032 ↗
12. 10.1080/00405000.2019.168688110.1080/00405000.2019.1686881 ↗
13. 10.1177/152808370708783310.1177/1528083707087833 ↗
14. 10.1177/004051750505419010.1177/0040517505054190 ↗
15. Derya T · Text Appar · 2019 · 29 · 279
16. 10.1186/s40691-020-00244-310.1186/s40691-020-00244-3 ↗
17. Kim S · PLoS ONE · 2023 · 18
18. NFPA 1971:2018. Standard on protective ensembles for structural fire fighting and proximity fire fighting.
19. ASTM F1868:2017. Standard test method for thermal and evaporative resistance of clothing materials using a sweating hot plate.
20. 10.1520/STP19903S10.1520/STP19903S ↗
21. ISO 17492:2019. Clothing for protection against heat and flame-determination of heat transmission on exposure to both flame and radiant heat.
22. Stoll AM · Aerosp Med · 1969 · 40 · 1232
23. ASTM F1291:2016. Standard test method for measuring the thermal insulation of clothing using a heated manikin.
24. ASTM F2370:2016. Standard test method for measuring the evaporative resistance of clothing using a sweating manikin.
25. 10.1177/004051751559692610.1177/0040517515596926 ↗
26. Burke R, Blood K, Deaton AS, et al. Application of model-controlled manikin to predict human physiological response in firefighter turnout gear. In: Proceddings of the 8th International Meeting for Thermal Manikin and Modeling (8I3M), Victoria, Canada, 2010. https://thermetrics.com/wp-content/uploads/2020/10/SET-Validation.paper1-R.Burke_.pdf
27. 10.1520/STP16242019007710.1520/STP162420190077 ↗
28. 10.1520/STP16242019007510.1520/STP162420190075 ↗
29. 10.1016/j.apergo.2018.03.00410.1016/j.apergo.2018.03.004 ↗
30. 10.1520/STP10451010.1520/STP104510 ↗
31. Wang F. · J Ergon · 2011 · 1
32. 10.1016/S0003-4878(99)00051-410.1016/S0003-4878(99)00051-4 ↗
33. Hunt AP · Mil Med Res · 2019 · 6 · 110.18502/rmm.v6i1.3919 ↗
34. 10.1016/j.ijthermalsci.2019.10602110.1016/j.ijthermalsci.2019.106021 ↗
35. 10.1186/cc697510.1186/cc6975 ↗
36. 10.1007/3-540-28862-7_710.1007/3-540-28862-7_7 ↗
37. 10.1177/004051751454525410.1177/0040517514545254 ↗
38. 10.1152/japplphysiol.00612.200710.1152/japplphysiol.00612.2007 ↗
39. 10.1533/9780857090645.3.30510.1533/9780857090645.3.305 ↗
40. 10.1007/s00421-008-0924-210.1007/s00421-008-0924-2 ↗
41. Dorman L
42. Slater K. · 1985
43. 10.3993/jfbi1220080110.3993/jfbi12200801 ↗
44. 10.1177/004051750505394910.1177/0040517505053949 ↗
45. 10.1177/00405175040740111010.1177/004051750407401110 ↗
46. 10.1177/004051751771209710.1177/0040517517712097 ↗
47. 10.1177/004051750809048410.1177/0040517508090484 ↗