Highlights of Magnetoelectropolishing
Source abstract
Abstract
The research work has been concerned on the studies and development of electrochemical polishing in the magnetic field (MEP) in comparison with the standard electropolishing methods performed without stirring (EP) and the process with the forced electrolyte mixing (MIX). Advanced techniques were used in the studies, to measure the effects of the surface treatment. They are as follows: scanning electron microscopy (SEM/EDS), X-ray Photoelectron Spectroscopy (XPS), Secondary Ion Mass Spectroscopy (SIMS), surface roughness, and nanoindentation measurements. For the corrosion studies, the electrochemical methods were used, such as: open circuit potential OCP, potentiodynamic curves PC, and electrochemical impedance spectroscopy EIS measurements. The MEP process is advised mainly due to the opportunity to enrich the surface layer with the chromium compounds (austenitic stainless steels), or titanium compounds (CP Ti Grade 2, Nitinol). The surface layers of biomaterials after MEP process contain much lower amount of carcinogenic compounds, like chromium VI oxidation stage (Cr6+) (austenitic stainless steels) and nickel compounds (austenitic stainless steel & Nitinol) versus those ones obtained after EP & MIX treatments. It is interesting that apart from the significant modification of the surface layer obtained after MEP, also mechanical properties, such as nanohardness, modulus of elasticity, and mechanical resistance to bending and torsion, undergo considerable advantageous changes. All they make the MEP process very promising for application in many clean industries, such as medical equipment and devices, electronics, food industry, etc.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Hydrogen embrittlement and corrosion behaviors in metals · Electrodeposition and Electroless Coatings
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. Effects of pulsed magnetic field on thrust bearing washer hardness10.1016/j.wear.2006.11.007 ↗
2. Technical note: novel surface treatment for 316L stainless steel using magnetisation technology10.1179/1433075X13Y.0000000101 ↗
3. Magnetic field effects in machining processes and on manufactured part mechanical characteristics10.1115/1.2113007 ↗
4. Introduction to Surface Finishing of Metallic Biomaterials (in Polish)
5. “On the surface modification of stainless steels,â€
6. “Improved surface properties of nitinol after magnetoelectropolishing,â€
7. Magnetoelectropolishing process improves characteristics of finished metal surfaces10.1016/S0026-0576(06)80361-2 ↗
8. Magnetoelectropolishing for metal surface modification10.1179/174591907X246537 ↗
9. Corrosion characteristics of medical grade AISI 316L stainless steel surface after electropolishing in a magnetic field10.5006/1.3279927 ↗
10. Electrochemical and XPS studies of AISI 316L stainless steel after electropolishing in a magnetic field10.1016/j.corsci.2008.06.048 ↗
11. Co-Cr alloy corrosion behaviour after electropolishing and “magnetoelectropolishing†treatments10.1016/j.matlet.2008.01.130 ↗
12. Corrosion and surface characterization of titanium biomaterial after magnetoelectropolishing10.1016/j.surfcoat.2008.11.028 ↗
13. Biomaterial studies on AISI 316L stainless steel after magnetoelectropolishing10.3390/ma2010129 ↗
14. “Surface investigation of NiTi rotary endodontic instruments after magnetoelectropolishing,â€
15. “Magnetoelectropolished titanium biomaterialâ€, Chapter 1110.5772/23105 ↗
16. SIMS analysis of hydrogen content in near surface layers of AISI 316L SS after electrolytic polishing under different conditions10.1016/j.surfcoat.2011.03.024 ↗
17. Auger/AES surface film measurements on AISI 316L biomaterial after magnetoelectropolishing
18. On the wear inspection and endurance recovery of nitinol endodontic files
19. Polarization characteristics of magnetoelectropolishing stainless steels10.1016/j.matchemphys.2010.02.055 ↗
20. Analysis of XPS results of AISI 316L SS electropolished and magnetoelectropolished at varying conditions10.1016/j.surfcoat.2010.02.005 ↗
21. Corrigendum to “SEM/EDX and XPS studies of niobium after electropolishing†by T. Hryniewicz, K. Rokosz, H.R. Zschommler Sandim [Appl. Surf. Sci., yyy (2012) xxx]10.1016/j.apsusc.2012.11.104 ↗
22. Significant improvement of AISI 316L SS biomaterial surface after magnetoelectropolishing MEP: XPS measurements
23. Corrosion resistance of magnetoelectropolished AISI 316L SS biomaterial10.1108/ACMM-03-2013-1249 ↗
24. Magnetic fields for electropolishing improvement: materials and systems
25. Effect of magnetoelectropolishing on nanohardness and Young’s modulus of titanium biomaterial10.1016/j.matlet.2012.06.010 ↗
26. SEM/EDX and XPS studies of niobium after electropolishing10.1016/j.apsusc.2012.09.060 ↗
27. Measurements of nanohardness and elasticity modulus of titanium after magnetoelectropolishing
28. 1975
29. Rokicki · 2009
30. Influence of sodium hypochlorite treatment of electropolished and magnetoelectropolished nitinol surfaces on adhesion and proliferation of MC3T3 pre-osteoblast cells10.1007/s10856-012-4696-1 ↗
31. Nitinolâ„¢ surface finishing by magnetoelectropolishing10.1179/174591908X345040 ↗
32. Enhanced oxidation-dissolution theory of electropolishing10.1179/0020296712Z.00000000031 ↗
33. Modifying metallic implants with magnetoelectropolishing, (invited paper)
34. Pomiar XPS składu chemicznego warstwy wierzchniej powstałej na stali austenitycznej AISI 316L SS po elektrochemicznym polerowaniu w polu magnetycznym (XPS measurement of chemical composition of surface layer formed on austenitic AISI 316L SS after electrochemical polishing in magnetic field) (in Polish)
35. Electrochemical Polishing of Steels in a Magnetic Field (in Polish)
36. Pitting corrosion resistance of AISI 316L SS in Ringer’s solution after magnetoelectrochemical polishing10.5006/1.3360910 ↗
37. Investigation of selected surface properties of AISI 316L SS after magnetoelectropolishing10.1016/j.matchemphys.2010.03.060 ↗
38. Effect of magnetic field on the pitting corrosion of austenitic steel type AISI 304
39. XPS measurements of LDX 2101 duplex steel surface after magnetoelectropolishing10.3139/146.110984 ↗
40. Cr/Fe ratio by XPS spectra of magnetoelectropolished AISI 316L SS using linear, Shirley and Tougaard method of background subtraction
41. Magnetoelectropolishing: modern and effective method of AISI 316L SS surface finishing
42. Characterization of passive film formed on AISI 316L stainless steel after magnetoelectropolishing in a broad range of polarization parameters10.1002/srin.201200046 ↗
43. XPS measurements of 4H13 martensitic steel after electropolishing operation with electrolyte stirring
44. Nanoindentation measurements of AISI 316L biomaterial samples after annual immersion in Ringer’s solution followed by electrochemical polishing in a magnetic field
45. Cr/Fe ratio by XPS spectra of magnetoelectropolished AISI 316L SS fitted by Gaussian-Lorentzian shape lines
46. Badania XPS stali martenzytycznej 4H13 po elektrochemicznym polerowaniu (XPS measurements of martensitic stainless steel 4H13 after the electrochemical polishing) (in Polish)
47. Magnetotribology of ferromagnetic/ferromagnetic sliding couple10.1016/j.wear.2007.01.081 ↗