Fully printed, stretchable and wearable bioimpedance sensor on textiles for tomography
Source abstract
Abstract
Abstract Electrical impedance tomography (EIT) is a non-invasive, real-time, continuous imaging technique that has multiple applications in health care. EIT is a realizable technique for radiation-free medical imaging ranging from real-time monitoring of bone fracture repair to lung functioning. This work explores the prospect of printing a wearable bioimpedance sensor on textiles for EIT imaging. Screen printing and stencil printing were applied to fabricate the sensor on the textile substrate and the imaging was carried out with the worn sensor on the human body. The first part of this work focuses on developing a flexible textile sensor in the form of a bracelet to obtain cross-sectional images of the forearm that unravel bone features like shape, size and position. However, body parts such as the thorax have added complexities due to their constantly varying perimeter and uneven shape. It is a significant prerequisite for the wearable sensors to apply to dynamic body parts where irregular shape and continuous volume variations occur. The second part of the paper therefore addresses the fabrication and testing of a stretchable textile-based sensor to address such instances of body dynamicity. The proposed stretchable sensor, worn on the thorax, demonstrates the feasibility of imaging such an uneven and dynamic body part. Although the EIT images are inherently attributed to low resolution, this work shows the prospect of wearable imaging applications in health monitoring. Apart from demonstrating the printed sensor for EIT imaging, this paper shows the image rendering quality dependency over the frequency of the signal and the number of electrodes. This work could initiate further research on wearable EIT based health monitoring devices for real-life scenarios.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrical and Bioimpedance Tomography · Advanced Sensor and Energy Harvesting Materials · Body Composition Measurement Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (71)
Show source-provided references
1. Advanced materials of printed wearables for physiological parameter monitoring10.1016/j.mattod.2019.08.005 ↗
2. Pooria · 2017 · 341
3. Wearable sensors for remote health monitoring10.3390/s17010130 ↗
4. Flexible sensors for chronic wound management10.1109/RBME.2013.2295817 ↗
5. Emerging flexible and wearable physical sensing platforms for healthcare and biomedical applications10.1038/micronano.2016.43 ↗
6. Smart fabric sensors and e-textile technologies: a review10.1088/0964-1726/23/5/053001 ↗
7. Wearable electronics and smart textiles: a critical review10.3390/s140711957 ↗
8. A wearable health care system based on knitted integrated sensors10.1109/TITB.2005.854512 ↗
9. Fully inkjet-printed two-dimensional material field-effect heterojunctions for wearable and textile electronics10.1038/s41467-017-01210-2 ↗
10. Flexible printed monolithic-structured solid-state dye sensitized solar cells on woven glass fibre textile for wearable energy harvesting applications10.1038/s41598-018-37590-8 ↗
11. Screen printed antennas on textile substrate
12. A novel design of E-textile integration for physiological monitoring and lighting
13. Urbaniak-Domagala · 2016 · 115
14. Printing smart designs of light emitting devices with maintained textile properties10.3390/ma11020290 ↗
15. Screen-printing fabrication and characterization of stretchable electronics10.1038/srep25784 ↗
16. Screen printed textile based wearable biopotential monitoring
17. A 4.9 mΩ-sensitivity mobile electrical impedance tomography IC for early breast-cancer detection system10.1109/JSSC.2014.2355835 ↗
18. Impedance sensing device enables early detection of pressure ulcers in vivo10.1038/ncomms7575 ↗
19. Dielectric properties of body tissues10.1088/0143-0815/8/4A/002 ↗
20. The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases10.3390/s140610895 ↗
21. Electrical impedance tomography (EIT): a review10.1080/0309190021000059687 ↗
22. Bioelectrical impedance methods for noninvasive health monitoring: a review
23. Bioelectric properties of tissue. Impedance measurement in clinical medicine. Significance of curves obtained
24. Bioimpedance imaging: an overview of potential clinical applications10.1039/c2an35874c ↗
25. Clinical usefulness of bioimpedance analysis for assessing volume status in patients receiving maintenance dialysis10.3904/kjim.2018.197 ↗
26. Bioimpedance spectroscopy for clinical assessment of fluid distribution and body cell mass10.1177/0115426507022004389 ↗
27. Wearable lung-health monitoring system with electrical impedance tomography
28. Combing signal processing methods with algorithm priori information to produce synergetic improvements on continuous imaging of brain electrical impedance tomography10.1038/s41598-018-28284-2 ↗
29. Teschner · 2015 · p 147
30. Tomo: wearable, low-cost electrical impedance tomography for hand gesture recognition
31. Biomechanical modeling of human skin tissue surrogates10.3390/biomimetics3030018 ↗
32. Gregor-Svetec · 2018 · 203
33. Kipphan · 2006
34. Torah · 2015
35. Electrical impedance tomography with a lab-on-chip for imaging cells in culture10.1002/pssa.201700868 ↗
36. Holder · 2004
37. The Sheffield data collection system10.1088/0143-0815/8/4A/012 ↗
38. Studying the resistivity imaging of chicken tissue phantoms with different current patterns in electrical impedance tomography (EIT)10.1016/j.measurement.2012.01.002 ↗
39. Mathematical aspects of impedance imaging10.1088/0143-0815/8/4A/010 ↗
40. Testing miniaturized electrodes for impedance measurements within the β-dispersion—a practical approach10.5617/jeb.111 ↗
41. A bio-impedance readout IC with frequency sweeping from 1 k-to-1 MHz for electrical impedance tomography
42. Uses and abuses of EIDORS: an extensible software base for EIT10.1088/0967-3334/27/5/S03 ↗
43. Wrist-wearable bioelectrical impedance analyzer with contact resistance compensation function
44. Signal path loss simulation of human arm for galvanic coupling intra-body communication10.15748/jasse.3.29 ↗
45. Sensitivity of transient temperature field in domain of forearm insulated by protective clothing with respect to perturbations of external boundary heat flux
46. Bone electrical impedance and tomographic reconstruction of fracture detection: a review
47. Smart bone plates can monitor fracture healing10.1038/s41598-018-37784-0 ↗
48. Electrical impedance tomography: a review of current literature10.1016/0720-048X(94)90329-8 ↗
49. The electric resistivity of human tissues (100 Hz–10 MHz): a meta- analysis of review studies10.1088/0967-3334/20/4/201 ↗
50. Influence of electrode placement error and contact impedance error to scalp voltage in electrical impedance tomography application
51. Assessment of errors in static electrical impedance tomography with adjacent and trigonometric current patterns10.1088/0967-3334/18/4/003 ↗
52. Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study10.1007/BF02520003 ↗
53. Electrical properties of tissues and cell suspensions: mechanisms and models
54. On the application of frequency selective common mode feedback for multifrequency EIT10.1088/0967-3334/36/6/1337 ↗
55. Multi-frequency electrical impedance tomography and neuroimaging data in stroke patients10.1038/sdata.2018.112 ↗
56. A versatile and reproducible multi-frequency electrical impedance tomography system10.3390/s17020280 ↗
57. Evaluating major electrode types for idle biological signal measurements for modern medical technology10.3390/bioengineering3030020 ↗
58. The impact of electrode area, contact impedance and boundary shape on EIT images10.1088/0967-3334/32/7/S02 ↗
59. Multifrequency electrical impedance tomography using spectral constraints10.1109/TMI.2013.2284966 ↗
60. Dry electrodes for bioimpedance measurements—design, characterization and comparison10.1088/2057-1976/aaea59 ↗
61. Aung · 2019 · 1
62. Anatomy: thoracic
63. Electrical impedance tomography: a new study method for neonatal respiratory distress syndrome
64. Tomografía de impedancia eléctrica en la lesión pulmonar aguda10.1016/j.medine.2011.11.004 ↗
65. Variability in EIT images of lung ventilation as a function of electrode planes and body positions10.2174/1874120701408010035 ↗
66. Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study10.1186/cc7900 ↗
67. Spatial resolution in electrical impedance tomography: a topical review10.5617/jeb.3350 ↗
68. The number of electrodes and basis functions in EIT image reconstruction10.1088/0967-3334/23/1/312 ↗
69. An EIT system for mobile medical diagnostics
70. A low-power and compact-sized wearable bio-impedance monitor with wireless connectivity
71. Biomedical sensor systems-on-chip