journal article·2021-07Open access

Heat Release Rate Characterization of NFPA 1403 Compliant Training Fuels

John W. Regan

Fire Technology· Volume 57· Issue 4

Abstract

Abstract When using solid fuels for live fire training,NFPA 1403: Standard on Live Fire Training Evolutionsrequires that the materials be wood based. While the standard offers guidance on the type of fuels that are permissible for use in training, it offers little in the way of quantitative methods of selecting an appropriately sized fuel package. In order to examine the effects of fuel mass and orientation on heat release behavior, free burn heat release rate (HRR) experiments were conducted on twenty-one wood-based training fuel packages and twelve comparison furniture items. Training fuel packages demonstrated peak HRRs ranging from 1.0 MW to 3.6 MW, with the total energy release between 210 MJ and 1615 MJ. The furniture items exhibited peak HRRs between 0.9 MW and 3.7 MW, with the total energy release between 180 MJ and 995 MJ. A least-squares linear regression analysis indicated a good linear fit between total energy release and fuel mass burned among the training fuel packages (R$$^2$$ $$=$$ 0.98), suggesting that the effective heat of combustion is approximately constant at 14.2 MJ/kg. Generally, peak HRR increased as initial fuel mass increased, although the relationship was more variable, with the peak HRRs of similarly sized training fuel packages varying by nearly 1 MW. The results indicated that while total energy release was dependent largely on the initial fuel mass, peak HRR and peak burning duration were also dependent on the orientation and type of fuel in the fuel package. Wood-based training fuel packages were capable of producing peak HRRs comparable to individual items of furniture, although the total energy release was typically higher for the training fuel packages compared to corresponding furniture items.
Source: crossref · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire dynamics and safety research · Occupational Health and Performance · Combustion and Detonation Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. Averill JD, Moore-Merrell L, Barowy A, Santos R, Peacock R, Notarianni KA, Wissoker D (2010) Report on residential fireground field experiments. NIST Technical Note 1661, National Institute of Standards and Technology, Gaithersburg, Maryland10.6028/NIST.TN.1661 ↗
2. Babrauskas V (1980) Estimating room flashover potential. Fire Technol 16:94–10310.1007/BF02351801 ↗
3. Babrauskas V, Grayson S (1990) Heat release in fires. Taylor, London
4. Bryant R, Mullholland G (2008) A guide to characterizing heat release rate measurement uncertainty for full-scale fire tests. Fire Mater 32:121–13910.1002/fam.959 ↗
5. Demers Associates Inc (1982) Two die in smoke training drill. Fire Service Today, pp 17–20
6. Dillon S, Kim W, Quintiere J (1998) Determination of properties and the prediction of the energy release rate of materials in the ISO 9705 room-corner test. NIST NIST-GCR-98-753, National Institute of Standards and Technology, Gaithersburg
7. Fent KW, Mayer A, Bertke S, Kerber S, Smith D, Horn G (2019) Understanding airborne contaminants produced by different fuel packages during training fires. J Occup Environ Hyg (2019)10.1080/15459624.2019.1617870 ↗
8. Fisher G (2015) Conducting NFPA 1403-compliant live burn training in acquired structures. Fire Engineering
9. Garcia K, Kauffman R (2009) Realistic live burn training you can afford. Fire Engineering
10. Horn G, Stewart J, Kesler R, DeBlois J, Kerber S, Fent K, Scott W, Fernhall B, Smith D (2019) Fire fighter and fire instructor’s physiological responses and safety in various training environments. Saf Sci 116:287–29410.1016/j.ssci.2019.03.017 ↗
11. Karsner L (1968) Burning characteristics of wooden pallets as a test fuel. Progress report serial no. 16437, Factory Mutual Research Corporation, Norwood
12. Kerber S (2012) Analysis of changing residential fire dynamics and its implications on firefighter operational timeframes. Fire Technol 48:865–89110.1007/s10694-011-0249-2 ↗
13. Kerber S (2012) Impact of ventilation on fire behavior in legacy and contemporary residential construction. Underwriters Laboratories, Northbrook
14. Khan M, Tewarson A, Chaos M (2002) SFPE handbook of fire protection engineering, 3rd edn, chap. Combustion characteristics of materials and generation of fire products. National Fire Protection Association, Quincy, Massachusetts
15. Madryzkowski D (2007) Fatal training fires: fire analysis for the fire service. In: INTERFLAM 2007 proceedings. Interscience Communications Ltd (2007)
16. Madrzykowski D (2017) Fire fighter equipment operational environment: evaluation of thermal conditions. Fire Protection Research Foundation, Quincy10.54206/102376/IGFM4492 ↗
17. National Fire Protection Association, Quincy, Massachusetts: NFPA 1403: Standard on Live Fire Training Evolutions (2018)
18. Ohaus Corporation, Pine brook, New Jersey: Manual for SD Series Bench Scale (2000)
19. Parker W (1984) Calculation of the heat release rate by oxygen consumption for various applications. J Fire Sci 2, 380–39510.1177/073490418400200505 ↗
20. Reeder F (2013) The NFPA 1403 debate. Fire Rescue
21. Regan J, Zevotek R (2018) Study of the fire service training environment: safety and fidelity in concrete live fire training buildings. Underwriters Laboratories, Columbia10.54206/102376/WXTW8877 ↗
22. Regan J, Zevotek R (2019) Evaluation of the thermal conditions and smoke obscuration of live fire training fuel packages. Underwriters Laboratories, Columbia10.54206/102376/KARU4002 ↗
23. Romano N, Tarley J (2002) Career lieutenant and fire fighter die in a flashover during a live-fire training evolution - Florida. NIOSH F2002-34, National Institute for Occupational Safety and Health
24. Rossi R (2003) Fire fighting and its influence on the body. National Institute for Occupational Safety and Health10.1080/0014013031000121968 ↗
25. Stakes K, Willi J (2019) Study of the fire service training environment: safety, fidelity, and exposure—cquired structures. Underwriters Laboratories, UL Firefighter Safety Research Institute, Columbia, Maryland10.54206/102376/CECI9490 ↗
26. Tarley J (2007) Career probationary fire fighter dies while participating in a live-fire training evolution at an acquired structure - Maryland. NIOSH F2007-09, National Institute for Occupational Safety and Health
27. Tarley J, Mezzanotte T (2001) Volunteer fire fighter dies and two others are injured during live-burn training - New York. NIOSH F2001-38, National Institute for Occupational Safety and Health
28. Weinschenk C, Madrzykowski D, Courtney P (2019) Impact of flashover fire conditions on exposed energized electrical cords/cables. Fire Technol 56:959–99110.1007/s10694-019-00915-8 ↗
29. Willi J, Horn G, Madrzykowski D (2016) Characterizing a Firefighter’s immediate thermal environment in live-fire training scenarios. Fire Technol 52(6): 1339–135010.1007/s10694-015-0555-1 ↗
30. Willi J, Stakes K, Regan J, Zevotek R (2018) Evaluation of ventilation-controlled fires in L-shaped training props. Underwriters Laboratories, Columbia