Structural Capacity of One-Way Spanning Large-Scale Cross-Laminated Timber Slabs in Standard and Natural Fires

Felix Wiesner, Alastair Bartlett, Siyimane Mohaine, Fabienne Robert, Robert McNamee, Jean-Christophe Mindeguia, Luke Bisby

Fire Technology· Volume 57· Issue 1

Abstract

Abstract This paper describes selected observations, measurements, and analysis from a series of large-scale experiments on cross-laminated timber (CLT) slabs that were exposed to fire from below, using four different heating scenarios, with a sustained mechanical loading of 6.3 kN m per metre width of slab. The deflection response and in-depth timber temperatures are used to compare the experimental response against a relatively simple structural fire model to assess the load bearing capacity of CLT elements in fire, including during the decay phase of natural fires. It is demonstrated that the ventilation conditions in experiments with a fixed fuel load are important in achieving burnout of the contents before structural collapse occurs. A mechanics-based structural fire model is shown to provide reasonably accurate predictions of structural failure (or lack thereof) for the experiments presented herein. The results confirm the importance of the ventilation conditions on the fire dynamics, burning duration, and the achievement of functional fire safety objectives (i.e. maintaining stability and compartmentation), in compartments with exposed CLT.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Wood Treatment and Properties · Fire effects on ecosystems · Fire effects on concrete materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (40)

Show source-provided references
1. Buchanan AH (2015) Fire resistance of multistorey timber buildings. In: Harada K, Matsuyama K, Himoto K, Nakamura Y, Wakatsuki K (eds) Fire science and technology 2015. Springer, Singapore, pp 9–16
2. Buchanan AH, Abu AK (2017) Structural design for fire safety. Wiley, New York
3. Gerhards CC (1982) Effect of moisture content and temperature on the mechanical properties of wood: an analysis of immediate effects. Wood and Fiber Science 14 (1):4–36
4. CEN (2009) Eurocode 5. Design of timber structures. Part 1-2: General. Structural fire design. European Committee for Standardisation, Brussels
5. Bartlett AI, Hadden RM, Hidalgo JP, Santamaria S, Wiesner F, Bisby LA, Deeny S, Lane B (2017) Auto-extinction of engineered timber: application to compartment fires with exposed timber surfaces. Fire Saf J 91:407–413. http://doi.org/10.1016/j.firesaf.2017.03.05010.1016/j.firesaf.2017.03.050 ↗
6. Crielaard R, van de Kuilen J-W, Terwel K, Ravenshorst G, Steenbakkers P (2019) Self-extinguishment of cross-laminated timber. Fire Saf J 105:244–260. https://doi.org/10.1016/j.firesaf.2019.01.00810.1016/j.firesaf.2019.01.008 ↗
7. Hadden RM, Bartlett AI, Hidalgo JP, Santamaria S, Wiesner F, Bisby LA, Deeny S, Lane B (2017) Effects of exposed cross laminated timber on compartment fire dynamics. Fire Saf J 91:480–489. https://doi.org/10.1016/j.firesaf.2017.03.07410.1016/j.firesaf.2017.03.074 ↗
8. Emberley R, Do T, Yim J, Torero JL (2017) Critical heat flux and mass loss rate for extinction of flaming combustion of timber. Fire Saf J. https://doi.org/10.1016/j.firesaf.2017.03.00810.1016/j.firesaf.2017.03.008 ↗
9. Gernay T (2019) Fire resistance and burnout resistance of reinforced concrete columns. Fire Saf J 104:67–78. https://doi.org/10.1016/j.firesaf.2019.01.00710.1016/j.firesaf.2019.01.007 ↗
10. Kodur V, Dwaikat M, Fike R (2010) High-temperature properties of steel for fire resistance modeling of structures. J Mater Civ Eng 22(5):423–434. https://doi.org/10.1061/(asce)mt.1943-5533.000004110.1061/(ASCE)MT.1943-5533.0000041 ↗
11. White RH, Dietenberger M (2001) Wood products: thermal degradation and fire. In: Encyclopedia of materials: science and technology. Elsevier Science Ltd., pp 9712–9716. https://www.fs.usda.gov/treesearch/pubs/874210.1016/B0-08-043152-6/01763-0 ↗
12. White RH, Woeste FE (2013) Post-fire analysis of solid-sawn heavy timber beams. STRUCTURE magazine, November 2013, pp 38–40. https://www.fs.usda.gov/treesearch/pubs/47253
13. Hopkin D, Schmid J, Friquin KL (2016) Timber structures subject to non-standard fire exposure—advances and challenges. Paper presented at the world conference on timber engineering, Vienna, Austria
14. Katakura Y, Kinjo H, Hirashima T, Yusa S, Saito K (2016) Deflection behaviour and load-bearing-period of structural glued laminated timber beams in fire including cooling phase. Paper presented at the structures in fire, Princeton
15. Epernon Fire Tests Programme (2018). http://www.epernon-fire-tests.eu/
16. CEN (2014) EN 1365-2 fire resistance tests for load bearing elements. Floors and roofs. European Committee for Standardisation, Brussels
17. CEN (2012) EN 1363-1 Fire resistance tests. Part 1: general requirements. European Committee for Standardisation, Brussels
18. CEN (2002) Eurocode 1. Actions on structures. European Committee for Standardisation, Brussels
19. Thomas PH, Heselden A (1972) Fully-developed fires in single compartments. Fire Research Note
20. CEN (2002) EN 1991-1-2 Eurocode 1. Actions on structures. General actions. Actions on structures exposed to fire. European Committee for Standardisation, Brussels
21. Beck JV (1962) Thermocouple temperature disturbances in low conductivity materials. J Heat Transf 84(2):124–131. https://doi.org/10.1115/1.368431010.1115/1.3684310 ↗
22. Fahrni R, Schmid J, Klippel M, Frangi A (2018) Correct temperature measurements in fire exposed wood. In: World conference on timber engineering, Seoul, South Korea
23. Bartlett AI, McNamee R, Robert F, Bisby LA (2020) Comparative energy analysis from fire resistance tests on combustible versus noncombustible slabs. Fire Mater 44(3):301–310. https://doi.org/10.1002/fam.276010.1002/fam.2760 ↗
24. McNamee R, Zehfuss J, Bartlett A, Bisby L, Heidari M, Robert F (2019) Enclosure fire dynamics with a combustible ceiling. In: Grayson S (ed) Interflam. Interscience Communications, London
25. Efron B (1979) Bootstrap methods: another look at the jackknife. Ann Stat 7(1):1–26. https://doi.org/10.1214/aos/117634455210.1214/aos/1176344552 ↗
26. Jönsson R, Pettersson O (1985) Timber structures and fire: a review of the existing state of knowledge and research requirements. Swedish Council for Building Research, Stockholm
27. Mindeguia JC, Mohaine S, Bisby L, Robert F, McNamee R, Bartlett A (2019) Thermo-mechanical behaviour of cross-laminated timber slabs under standard and natural fires. In: Grayson S (ed) Interflam. Interscience Communications, London
28. CEN (2009) EN 338 structural timber—strength classes. European Committee for Standardisation, Brussels
29. Joint Committee on Structural Safety (JCSS) (2001) Probabilistic model code
30. APA (2018) PRG 320 standard for performance-rated cross-laminated timber. APA-The Engineered Wood Association, Tacoma
31. Wiesner F, Bisby LA, Bartlett AI, Hidalgo JP, Santamaria S, Deeny S, Hadden RM (2019) Structural capacity in fire of laminated timber elements in compartments with exposed timber surfaces. Eng Struct 179:284–295. https://doi.org/10.1016/j.engstruct.2018.10.08410.1016/j.engstruct.2018.10.084 ↗
32. Blass HJ, Fellmoser P (2004) Design of solid wood panels with cross layers. Paper presented at the 8th world conference on timber engineering,
33. Wiesner F, Bell D, Chaumont L, Bisby L, Deeny S (2018) Rolling shear capacity of CLT at elevated temperature. In: World conference on timber engineering, Seoul, Republic of Korea
34. CEN (2014) Eurocode 5. Design of timber structures. Part 1-1: general. Common rules and rules for buildings. European Committee for Standardisation, Brussels
35. Bartlett A, Law A, Jansson McNamee R, Zehfuss J, Mohaine S, Tessier C, Bisby L (2019) Heat fluxes to a façade resulting from compartment fires with combustible and non-combustible ceilings. In: 3rd international symposium for fire safety of Façades, Paris
36. König J, Walleij L (2000) Timber frame assemblies exposed to standard and parametric fires: part 2: a design model for standard fire exposure. Institutet för Träteknisk Forskning 0001001:1–76
37. Schmid J, Klippel M, Just A, Frangi A (2014) Review and analysis of fire resistance tests of timber members in bending, tension and compression with respect to the reduced cross-section method. Fire Saf J 68:81–9910.1016/j.firesaf.2014.05.006 ↗
38. Wiesner F, Randmael F, Wan W, Bisby L, Hadden RM (2017) Structural response of cross-laminated timber compression elements exposed to fire. Fire Saf J 91(Supplement C):56–67. https://doi.org/10.1016/j.firesaf.2017.05.01010.1016/j.firesaf.2017.05.010 ↗
39. Lineham SA, Thomson D, Bartlett AI, Bisby LA, Hadden RM (2016) Structural response of fire-exposed cross-laminated timber beams under sustained loads. Fire Saf J 85:23–34. http://doi.org/10.1016/j.firesaf.2016.08.00210.1016/j.firesaf.2016.08.002 ↗