journal article·2023-03Open access

Impact of Mass Timber Compartment Fires on Façade Fire Exposure

Thomas Engel, Norman Werther

Fire Technology· Volume 59· Issue 2

Abstract

Abstract This study investigates whether timber surfaces that are initially exposed to fire or partially protected timber components can lead to a more critical fire exposure on the façade. Five full-scale fire tests were carried out. Three tests with a square compartment (4.5 × 4.5 m2) and two with a double-width compartment (4.5 × 9 m2). The tests were conducted with a high fire load density (1085 MJ/m2). While the first test was carried out in a non-combustible compartment, the exposed timber surfaces were subsequently increased in the other tests. The measured compartment gas temperature, heat release rate, temperature on the façade, flame heights along the façade, heat flux and velocities along the façade are presented in this publication. The influence of exposed or only initially protected timber surfaces on the fire impact on the façade is investigated with the help of these results. Finally, these findings are presented and compared with the results of other internationally conducted fire tests from literature. Additional structural fire load leads to an increase in temperatures on the façade. However, there is no significant difference in flame height between the tests. Another result was that an exposed mass timber ceiling leads to higher heat fluxes on the façade than an exposed mass timber wall. Graphical Abstract
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Fire effects on ecosystems · Fire effects on concrete materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (54)

Show source-provided references
1. Reitan NK, Friquin KL, Mikalsen RF (2019) Brannsikkerhet ved bruk av krysslaminert massivtre i bygninger—en litteraturstudie. Rep. 2019:09 RISE Research Institues of Sweden, Trondheim
2. Friquin KL, Reitan NK, Mikalsen RF (2019) Fire exposure on façades of cross-laminated timber buildings—a review. In: FSF 2019—3rd international symposium on fire safety of façades, Paris
3. Brandon D, Just A, Andersson P, Östman B (2018) Mitigation of fire damages in multi-storey timber buildings - statistical analysis and guidelines for design. Rep. RISE Report 2018:43, RISE Research Institues of Sweden, Stockholm
4. Göldner M (2021) Evaluation of fire and hazard prevention measures - Part 4: Determination and evaluation of quantified propagation factors (Evaluierung der Maßnahmen des vorbeugenden Brand- und Gefahrenschutzes—Teil 4: Ermittlung und Bewertung quantifizierter Ausbreitungsfaktoren). Master Thesis, Technical University of Munich
5. Maiworm B (2021) Göldner M (2021) Einsatzstellenbegehungen—Fokus: Hat das Gebäude funktioniert? Braunschweiger Brandschutz-Tage 241:63–82
6. Gorska C (2019) Fire dynamics in multi-scale timber compartments. Dissertation, The University of Queensland
7. Gorska C, Hidalgo JP, Torero JL (2021) Fire dynamics in mass timber compartments. Fire Saf J https://doi.org/10.1016/j.firesaf.2020.10309810.1016/j.firesaf.2020.103098 ↗
8. Nothard S, Lange D, Hidalgo J P, Gupta V, McLaggan M S (2020) The response of exposed timber in open plan compartment fires and its impact on the fire dynamics. In: SiF 2020—The 11th international conference on structures in fire, Brisbane. https://doi.org/10.14264/5d9778510.14264/5d97785 ↗
9. Bartlett AI, Kanellopoulos G, Law A (2019) Heat flux distribution on a facade from timber-lined compartments. In: 15th International conference and exhibition on fire science and engineering (Interflam 2019), 1995–2002, London
10. Berger H (2021) Investigation of the effects between full scale and small scale fire tests (Untersuchung der Skalierungseffekte bei Brandversuchen). Master Thesis, Technical University of Munich
11. Maag T, Fontana M (2000) Brandversuche an Modulhotels in Holzbauweise. Report, Swiss Federal Institute of Technology ETH Zurich, Zurich. https://doi.org/10.3929/ethz-a-00403100410.3929/ethz-a-004031004 ↗
12. Frangi A, Fontana M (2005) Fire performance of timber structures under natural fire conditions. Proc Fire Saf Sci 8:279–290. https://doi.org/10.3801/IAFSS.FSS.8-27910.3801/IAFSS.FSS.8-279 ↗
13. Su J, Lougheed GD (2014). Fire safety summary - Fire research conducted for the project on mid-rise wood construction. Client Report A1-004377.1, National Research Council Canada
14. Hakkarainen T (2002) Post-flashover fires in light and heavy timber construction compartments. J Fire Sci 20:133–175. https://doi.org/10.1177/073490410202000207410.1177/0734904102020002074 ↗
15. Su J, Leroux P, Lafrance P-S, Berzins R, Gratton K, Gibbs E, Weinfurter M (2018). Fire testing of rooms with exposed wood surfaces in encapsulated mass timber construction. Client Report A1-012710.1, National Research Council Canada
16. Hadden RM, Bartlett AI, Hidalgo JP, Santamaria S, Wiesner F, Bisby LA, Deeny S, Lane B (2017) Effects of exposed cross laminated timber on compartment fire dynamics. Fire Saf J 91:480–489. https://doi.org/10.1016/j.firesaf.2017.03.07410.1016/j.firesaf.2017.03.074 ↗
17. Su J, Lafrance P-S (2018). Fire safety challenges of tall wood buildings—phase 2: task 2 & 3—cross laminated timber compartment fire tests. NFPA Rep. No. FPRF-2018-01. NRC Rep. No. A1-012710.1, National Research Council Canada
18. Épernon Fire Tests Programme (2020) Synthesis Report; Report No. EFTP-2020/01, October 13, 2020. http://www.epernon-fire-tests.eu/
19. Bartlett A, Law A, McNamee RJ, Zehfuss J, Mohaine S, Tessier C, Bisby L (2019) Heat fluxes to a façade resulting from compartment fires with combustible and non-combustible ceilings. In: FSF 2019—3rd international symposium on fire safety of façades, Paris
20. Robert F et al (2019) ÉPERNON FIRE TESTS PROGRAMME—Test Report No. 013598: CLT slab (Natural Fire Test—Scenario 2), CERiB FireTesting Centre, France. http://www.epernon-fire-tests.eu
21. Robert F et al (2019) ÉPERNON FIRE TESTS PROGRAMME—Test report No. 013597: CLT slab (Natural Fire Test—Scenario 2), CERiB FireTesting Centre, France. http://www.epernon-fire-tests.eu
22. Robert F et al (2019) ÉPERNON FIRE TESTS PROGRAMME—Test Report No. 013599: CLT slab (Natural Fire Test—Scenario 2), CERiB FireTesting Centre, France. http://www.epernon-fire-tests.eu
23. Robert F et al (2019) ÉPERNON FIRE TESTS PROGRAMME - Test report n° 013600: CLT slab (Natural Fire Test—Scenario 2), CERiB FireTesting Centre, France. http://www.epernon-fire-tests.eu
24. Brandon D, Sjöström J, Temple A, Hallberg E, Kahl F (2021) Final project report—fire safe implementation of visible mass timber in tall buildings—compartment fire testing. RISE Report 2021:40, RISE Research Institues of Sweden
25. Sjöström J, Brandon D, Temple A, Hallberg E, Kahl F (2021) Exposure from mass timber compartment fires to facades. RISE Report 2021:39, RISE Research Institues of Sweden
26. Kotsovinos P, Rackauskaite E, Christensen E, Glew A, O’Loughlin E, Mitchell H, Amin R, Robert F, Heidari M, Barber D, Rein G, Schulz J (2022) Fire dynamics inside a large and open-plan compartment with exposed timber ceiling and columns: CodeRed #01. Fire Mater. https://doi.org/10.1002/fam.304910.1002/fam.3049 ↗
27. Rackauskaite E, Bonner M, Restuccia F et al (2021) Fire experiment inside a very large and open-plan compartment: x-ONE. Fire Technol 58:905–939. https://doi.org/10.1007/s10694-021-01162-610.1007/s10694-021-01162-6 ↗
28. Heidari M (2021) Travelling fires methodology and probabilistic design of structures. PhD thesis. Imperial College London
29. Kotsovinos P, Christensen EG, Rackauskaite E, Glew A, O’Loughlin E, Mitchell H, Amin R, Robert F, Heidari M, Barber D, Rein G, Schulz J (2022) Impact of ventilation on the fire dynamics of an open-plan compartment with exposed timber ceiling and columns: CodeRed #02. Fire Mater. https://doi.org/10.1002/fam.308210.1002/fam.3082 ↗
30. Engel T, Brunkhorst S, Steeger F, Butscher D, Kurzer C, Werther N, Winter S, Zehfuß J, Kampmeier B, Neske M (2022) Schlussbericht zum Verbundvorhaben TIMpuls—Brandschutztechnische Grundlagenuntersuchung zur Fortschreibung bauaufsichtlicher Regelungen im Hinblick auf eine erweiterte Anwendung des Holzbaus. Fachagentur Nachwachsende Rohstoffe; Gülzow-Prüzen. https://doi.org/10.14459/2022md166141910.14459/2022md1661419 ↗
31. German Institute for Standardization (2015) DIN EN 1991-1-2/NA National Annex—Nationally determined parameters—Eurocode 1: actions on structures—Part 1–2: general actions—actions on structures exposed to fire. German Institute for Standardization, Berlin
32. European Committee for Standardization (2013) EN 60584-1 Thermocouples—Part 1: EMF specifications and tolerances (IEC 60584-1:2013). European Committee for Standardization, Brussels
33. European Committee for Standardization (2020) EN 1363-1:2020 Fire resistance tests—Part 1: general requirements. European Committee for Standardization, Brussels
34. Starke H (2009) Kalibrierung von bidirektionalen Sonden—calibration of bidirectional probes. Jahresbericht 2006/2007/2008, IdF Sachsen-Anhalt, Heyrothsberge 2009
35. Brunkhorst S, Zehfuß J, Engel T, Kurzer C, Werther N, Steeger F, Butscher D (2021) TIMpuls Grossversuche an Holzbauten. Braunschweiger Brandschutz-Tage 2021
36. Standard E (2009) Eurocode 5: Design of timber structures—part 1–2: general—structural fire design; German version EN 1995-1-2:2004 + AC:2009. European Committee for Standardization, Brussels
37. European Committee for Standardization (2019) EN 13381-7 Test methods for determining the contribution to the fire resistance of structural members—Part 7: applied protection to timber members. European Committee for Standardization, Brussels
38. Ahrens J (2021) Influence of the immobile fire load on the fire effect on the façade (Einfluss der immobilen Brandlast auf die Brandeinwirkung auf der Fassade). Master Thesis, Technical University of Munich
39. Häggkvist A, Sjöström J, Wickström U (2021) Using plate thermometer measurements to calculate incident heat radiation. J Fire Sci 31(2):166–177. https://doi.org/10.1177/073490411245926410.1177/0734904112459264 ↗
40. Ingason H, Wickström U (2007) Measuring incident radiant heat flux using the plate thermometer. Fire Saf J 42:161–166. https://doi.org/10.1016/j.firesaf.2006.08.00810.1016/j.firesaf.2006.08.008 ↗
41. European Standard (2009) Eurocode 1: Actions on structures—Part 1–2: general actions—actions on structures exposed to fire; EN 1991-1-2:2002 + AC:2009
42. Engel T, Werther N (2020) Analyse der zulässigen Brandausbreitung über die Fassade. Bautechnik 97:558–565. https://doi.org/10.1002/bate.20200000710.1002/bate.202000007 ↗
43. European Commission (1994) Communication of the Commission with regard to the interpretative documents of Council Directive 89/106/EEC (94/C 62/01). Official Journal of the European Communities
44. NFPA (2016) NFPA 14—Standard for the Installation of Standpipe and Hose Systems
45. Babrauskas V (2010) Glass breakage in fires. https://fireevacuationplan.ru/articles/dataFolder/to139_GlassBreak.pdf. Accessed 16 May 2022
46. Morris B (1999) Fire spread in multi-storey buildings with glazed curtain wall facades. (LPR 11: 1999), Loss Prevention Council, Borehamwood, England
47. Brunkhorst S, Zehfuß J (2020) Experimental and numerical analysis of fire development in compartment fires with immobile fire load. In: International scientific conference on woods & fire safety. https://doi.org/10.1007/978-3-030-41235-7_2810.1007/978-3-030-41235-7_28 ↗
48. Hopkin D, Wegrznski W, Spearpoint M, Fu I, Krenn H, Sleik T, Gorska C, Stapf G (2022) Large-scale enclosure fire experiments adopting CLT slabs with different types of polyurethane adhesives: genesis and preliminary findings. Fire 5:39. https://doi.org/10.3390/fire502003910.3390/fire5020039 ↗
49. DS/EN 1991-1-2 DK NA:2014 National Annex to Eurocode 1: actions on structures—Part 1–2: general actions—actions on structures exposed to fire
50. NF EN 1991-1-2/NA:2007 Annexe nationale à la Eurocode 1—Actions sur les structures—Partie 1–2 : Actions générales—Actions sur les structures exposées au feu
51. NA to BS EN 1991-1-2:2002 UK National Annex to Eurocode 1: Actions on structures—Part 1–2: general actions—actions on structures exposed to fire
52. PD 6688-1-2:2007 Background paper to the UK National Annex to BS EN 1991-1-2
53. N.A. to I.S. EN 1991-1-2:2002 Irish National Annex to Eurocode 1: actions on structures—Part 1–2: general actions—actions on structures exposed to fire
54. Appendice Nazionale Italiana alla UNI EN 1991-1-2:2005 Parametri adottati a livello nazionale da utilizzare per le strutture esposte al fuoco