Critical factors governing the fire performance of high strength concrete systems

V.K.R. Kodur, L. Phan

Fire Safety Journal· Volume 42· Issue 6-7
Publisher page

Abstract

High strength concrete (HSC), is being increasingly used in a number of building applications, where structural fire safety is one of the major design considerations. Many research studies clearly indicate that the fire performance of HSC is different from that of normal strength concrete (NSC) and that HSC may not exhibit same level of performance (as NSC) in fire. This paper discusses the material, structural and fire characteristics that influence the performance of HSC under fire conditions. Data from earlier experimental and numerical studies is used to illustrate the impact the concrete (material) mix design and structural detailing (design) has on fire performance of HSC systems. An understanding of various factors influencing fire performance will aid in developing appropriate solutions for mitigating spalling and enhancing fire resistance of HSC members.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fire effects on concrete materials · Fire dynamics and safety research · Engineering and Material Science Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. Phan LT. Fire performance of high-strength concrete: a report of the state-of-the-art, National Institute of Standards and Technology, Gaithersburg, MD; p. 1996, 105.10.6028/NIST.IR.5934 ↗
2. Diederichs U, Jumppanen UM, Schneider U. High temperature properties and spalling behaviour of HSC, In: Proceedings of 4th Weimar workshop on HPC, HAB Weimar, Germany; 1995, p. 219–35.
3. Kodur VR, Sultan MA. Structural behaviour of high strength concrete columns exposed to fire. In: Proceedings: international symposium on high performance and reactive powder concrete, vol. 4, Sherbrooke, Quebec; 1998. p. 217–32.
4. Danielsen Ulf. Marine concrete structures exposed to hydrocarbon fires, Report, SINTEF—The Norwegian Fire Research Institute; p. 1997, 56–76.
5. Bilodeau A, Kodur VR, Hoff GC. Optimization of the type and amount of polypropylene fibres for preventing the spalling of lightweight concrete subjected to hydrocarbon fire, Cem Concr Compos J 2004; 26(2): 163–75.10.1016/S0958-9465(03)00085-4 ↗
6. Limits of spalling of fire-exposed concrete10.1016/S0379-7112(02)00051-6 ↗
7. ACI Committee 318. Building code requirements for reinforced concrete (ACI 318-02), American Concrete Institute, Detroit; 2002.
8. Canadian Standards Association. Code for the design of concrete structures for buildings. CAN3-A23.3-M02, Rexdale, ON; 2002.
9. ACI Committee 216. Standard method for determining fire resistance of concrete and masonry construction assemblies, Am Concr Inst, Detroit; 1997.
10. Effects of test conditions and mixture proportions on behavior of high-strength concrete exposed to high temperatures
11. Fire endurance of high strength concrete columns10.1023/A:1021731327822 ↗
12. Predicting the fire resistance behaviour of high strength concrete columns10.1016/S0958-9465(03)00089-1 ↗
13. Effect of strength and fiber reinforcement on the fire resistance of high strength concrete columns10.1061/(ASCE)0733-9445(2003)129:2(253) ↗
14. Outcomes of a major research on fire resistance of concrete columns10.1016/j.firesaf.2004.02.004 ↗
15. DeCicco PR, Cresci RJ, Correale WH. Fire tests, analysis and evaluation of stair pressurization and exhaust in high rise office buildings, Brooklyn Polytechnic Institute; 1972.
16. Effect of silica fume and confinement on fire performance of high strength concrete columns10.1139/l05-089 ↗
17. Kodur VR. Fiber reinforcement for minimizing spalling in HSC structural members exposed to fire. Innovations in fibre-reinforced concrete for value, ACI Special Publication SP: 216; 2003. p. 221–36.