Shear Behavior of Lapped Connections Bolted by thread-fixed one-side bolts at elevated temperatures
Source abstract
Abstract
Abstract The Thread-fixed One-side Bolt (TOB) is the bolt that can be installed from outside of a steel tube column, which is anchored by the threads on the bolt hole wall instead of the nuts. A series of tests were carried out to investigate the shear behavior of the lapped connection bolted by TOBs using both the steady state fire tests and the transient state fire tests. The two observed failure modes of TOB connected lapped connections were the bolt hole bearing failure (failure mode 1) and the bolt shank fracture (failure mode 2). The high temperature might cause the change of failure mode from failure mode 1 to failure mode 2. Lapped connections using Standard High Strength Bolt (SHSB) were also tested. The comparison results showed that the ultimate shear resistance of lapped connections using TOBs at different temperatures was about 90% of that using SHSBs with the same configuration at steady state fire test. Applicability of the design equations provided by Eurocode 3 was validated by the steady state fire test results. A Finite Element Model (FEM) was built and validated by the test results and the FEM was used to further study more derailed parameter studies including the influence of bolt strength, the bolt pretension force and the high temperature to the shear behavior of TOB connected lap connections.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fire effects on concrete materials · Structural Response to Dynamic Loads · Transportation Safety and Impact Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. Numerical performance of blind-bolted demountable square CFST K-joints
2. Tensile behaviour of double headed anchored blind bolt in concrete filled square hollow section under cyclic loading10.1016/j.conbuildmat.2018.12.089 ↗
3. Experimental study on the depth of high strength bolt into bolt-sphere joint
4. Screwed connections of thin sheet steels at elevated temperatures – Part I: steady state tests10.1016/j.engstruct.2011.10.030 ↗
5. Screwed connections of thin sheet steels at elevated temperatures – Part II: transient state tests10.1016/j.engstruct.2011.10.027 ↗
6. Transient state tests of cold-formed stainless steel single shear bolted connections10.1016/j.engstruct.2014.09.031 ↗
7. Steady- and transient-state response of cold-formed steel-to-steel screwed connections at elevated temperatures10.1016/j.jcsr.2018.01.016 ↗
8. Tension strength and design method for thread-fixed one-side bolted T-stub10.1016/j.engstruct.2017.07.093 ↗
9. Behaviour of stainless and high strength steel bolt assemblies at elevated temperatures — a review
10. Double-shear tests of high-strength structural bolts at elevated temperatures10.1016/j.firesaf.2017.09.003 ↗
11. Effect of preloading in high-strength bolts on bolted-connections exposed to fire10.1016/j.firesaf.2017.04.030 ↗
12. Post-fire residual slip resistance and shear capacity of high-strength bolted connection10.1016/j.jcsr.2017.06.026 ↗
13. Experimental study on tension behavior of bolt-sphere joints in high temperature
14. Fire performance of blind-bolted connections to concrete filled tubular columns in tension10.1016/j.engstruct.2015.03.067 ↗
15. Experimental studies on thread-fixed one-side bolted T-stubs in tension at elevated temperatures
16. Behavior of thread-fixed one-side bolted T-stubs with backing plates at ambient and elevated temperatures
17. Cyclic loading behavior of an innovative semi-rigid connection for engineered bamboo-steel hybrid frames
18. Analytical prediction of the fire resistance of the glulam bolted connections under coupled moment and shear
19. Shear behavior of lap connection using one-side bolts10.1016/j.engstruct.2019.02.012 ↗
20. Design of steel structures, Part 1–8: design of joints
21. 2003
22. 2002
23. 1998
24. 2003
25. Physical properties of high-strength bolt materials at elevated temperatures